检测青光眼眼压谐波频率及自我眼压监测所需采样目标
本研究对69例青光眼患者137只眼的286个家庭眼压监测模块应用多谐波非均匀离散傅里叶变换(NDFT)分析,检测1至10次/日的整数谐波频率。结果显示35.7%的模块可表征24小时节律(F1),44.8%至少表征F1-F4之一;模型预测在4周内约100-130次观测可使检出概率达75%-85%,约150次观测升至90%。
要点
- 近半数接受治疗青光眼患者的自我眼压监测模块可检出至少一个可表征的24小时整数谐波节律。
- F1(24小时节律)在35.7%的监测模块中被表征,F1-F4任一被表征的比例为44.8%。
- 4周内约100-130次观测且覆盖15个以上时钟小时时,模型预测检出概率为75%-85%。
核心结论
- 在近半数接受治疗的青光眼患者中,通过适当的自我眼压监测方案可检出至少一个可表征的24小时整数眼压谐波节律。
研究设计与样本
- 对69例青光眼患者137只眼的286个家庭眼压监测模块应用多谐波非均匀离散傅里叶变换(NDFT),并以bootstrap振幅置信区间和Lomb-Scargle周期图(LSP)独立确认。
主要发现
- 24小时节律(F1)在35.7%的监测模块中被表征,F1至F4中至少一个被表征的比例为44.8%(128/286)。
- 在128个模块中,34%(43个)同时表征2个或以上谐波,7%(9个)表征3个或以上。
- 检出的周期性几乎全部为整数谐波,非整数LSP峰仅出现在3.1%的模块(9/286)。
关键数值与推荐
- 频率被表征需满足噪声阈值显著性、振幅95%置信下限大于0且相位95%置信区间符合预设标准。
- 当15个以上时钟小时各含至少2次观测且连续无观测或仅1次观测的时钟小时不超过2个时,4周内约100至130次观测的模型预测检出概率为75%至85%,约150次观测升至90%。
临床怎么用
- 设计自我眼压监测方案时需考虑总观测次数、时钟小时覆盖和最长稀疏数据间隔,以优化谐波节律的检出。
- 对于接受治疗的青光眼患者,可依据模型预测的采样目标(4周约100-150次观测)安排家庭眼压监测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study was to determine the detectability and occurrence of circadian and ultradian rhythms in patient-acquired intraocular pressure (IOP) measurements with sampling targets for reliable harmonic detection. METHODS: A multi-harmonic non-uniform discrete Fourier transform (NDFT), with bootstrap amplitude confidence intervals and independent Lomb-Scargle periodogram (LSP) confirmation, was applied to 286 home-tonometry monitoring blocks from 137 eyes of 69 patients with glaucoma. Integer harmonic frequencies (F) from 1 to 10 cycles per day were tested. Characterized frequency was defined when noise-threshold significance, amplitude lower 95% confidence bound >0, and phase 95% confidence interval met prespecified criteria. Detection probability was modeled by a logistic generalized additive model (GAM) accounting for total observation count, clock-hour coverage, and the longest sparse-data gap. RESULTS: The 24-hour rhythm (F1) was characterized in 35.7% of blocks; at least one of F1, F2, F3, or F4 was characterized in 44.8% (128/286). Of these 128 blocks, 34% (43) had 2 or more harmonics simultaneously characterized and 7% (9) had 3 or more. Detected periodicities were almost exclusively integer harmonics. Non-integer LSP peaks arose in only 3.1% of blocks (9/286). Where 15 or more clock-hours contained at least 2 observations and no more than 2 consecutive clock-hours contained one or none, approximately 100 to 130 observations over 4 weeks gave a model-predicted detection probability of 75% to 85%, rising to 90% at approximately 150 observations. CONCLUSIONS: One or more characterizable 24-hour integer IOP harmonic rhythms could be detected with an appropriate self-tonometry protocol in nearly half of treated patients with glaucoma.
引用
- Morgan WH, Chiu CC, Turpin A, et al. Detecting Intraocular Pressure Harmonic Frequencies in Glaucoma and the Sampling Targets Needed to Identify Them With Self-Tonometry. Invest Ophthalmol Vis Sci. 2026. PMID: 42904889. doi:10.1167/iovs.67.12.37
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。