睫状体-晶状体距离与原发性闭角型青光眼前房深度的关联
本研究采用3.0T眼部MRI横断面观察原发性闭角型青光眼(PACG)患者与健康对照的晶状体及睫状体空间特征。结果显示PACG组晶状体截面积更大、睫状体间距(CCD)和睫状体-晶状体距离(CLD)更小,CLD对PACG具有高预测性能(AUC=0.979),提示较小的CLD与浅前房相关并指示拥挤的睫状体-晶状体构型。
要点
- PACG组CLD显著小于健康对照组(0.51±0.09 mm vs. 0.85±0.17 mm,P<0.001)。
- CLD预测PACG的AUC为0.979,接近经典参数前房深度(AUC=0.993)。
- PACG组晶状体截面积更大、CCD更小,LED和玻璃体腔参数无差异。
核心结论
- 较小的睫状体-晶状体距离(CLD)与前房变浅相关,并指示更拥挤的睫状体-晶状体构型,是PACG的关键指示指标。
研究设计与样本
- 横断面观察性病例对照研究,使用临床3.0T MRI联合专用线圈采集轴位双眼图像。
主要发现
- PACG组晶状体截面积显著大于对照组(33.72±2.50 mm² vs. 30.72±2.42 mm²,P=0.005)。
- PACG组睫状体间距(CCD)显著低于对照组(9.74±0.45 mm vs. 10.41±0.62 mm,P=0.003)。
- PACG组CLD显著低于对照组(0.51±0.09 mm vs. 0.85±0.17 mm,P<0.001)。
- 晶状体赤道直径(LED)和玻璃体腔特征参数两组间无差异。
- CLD对PACG具有高预测性能(AUC=0.979),接近前房深度(AUC=0.993),两者均有统计学意义(P<0.001)。
临床怎么用
- 眼部MRI测量的CLD可作为评估PACG睫状体-晶状体构型的影像学指标。
- CLD对PACG的预测性能接近前房深度,提示其可作为辅助判断PACG风险的参数。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the lens and ciliary spatial characteristics in primary angle-closure glaucoma (PACG) patients using ocular magnetic resonance imaging (MRI), aiming to elucidate the mechanism underlying PACG pathogenesis. METHODS: This is a cross-sectional observational case-control study that used a clinical 3.0T MRI with a specialized coil to acquire binocular images in the axial plane. Quantitative measurements were conducted to obtain anatomical parameters of the lens, ciliary body, and vitreous cavity, including lens equator diameter (LED), cilio-lenticular distance (CLD), ciliary to ciliary distance (CCD), vitreous cavity width, and vitreous cavity depth. Linear mixed effects models were used for statistical analysis. RESULT: Twenty-five eyes of 13 PACG patients and 19 eyes of 10 healthy participants were enrolled in this study. The PACG group exhibited a statistically significant larger Sectional Area of Lens (33.72 ± 2.50 mm2 vs. 30.72 ± 2.42 mm2, P = 0.005), lower CCD (9.74 ± 0.45 mm vs. 10.41 ± 0.62 mm, P = 0.003), and lower CLD (0.51 ± 0.09 mm vs. 0.85 ± 0.17 mm, P < 0.001). No differences were found in LED and characteristic parameters of vitreous cavities. CLD demonstrated a high predictive performance for PACG (area under the curve [AUC] = 0.979), approaching that of the classical parameter anterior chamber depth (AUC = 0.993), with both showing statistical significance (P < 0.001). CONCLUSIONS: A smaller CLD correlates with a shallow anterior chamber and indicates a more crowded ciliary-lens configuration, a crucial indictor of PACG.
引用
- Lei C, Zuo J, Lin H, et al. Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma. Invest Ophthalmol Vis Sci. 2026. PMID: 42929687. doi:10.1167/iovs.67.12.64
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。