文献速递白内障与屈光手术

折射型扩展景深人工晶状体在微单眼视与正视状态下的视觉表现

Visual Performance of a Refractive Extended Depth of Field Intraocular Lens in Monovision and Emmetropic Settings.
PubMed 文献 · Am J Ophthalmol · 2026-09-12

术后3个月两组双眼裸眼及矫正远视力、中距视力无显著差异,正视组低对比度视力显著更优,微单眼视组近距眼镜依赖稍低但眩光增加。

要点

  • 双眼植入DEN00V在微单眼视或正视目标下均提供优异的远、中距视力。
  • 正视组在5%和1.25%对比度下低对比度视力显著优于微单眼视组。
  • 微单眼视组近距眼镜依赖稍低但眩光主观视觉现象增加。

核心结论

  • 双眼植入折射型扩展景深人工晶状体DEN00V在微单眼视或正视状态下均提供优异的远距和中距视力、良好的低对比度视力并保留立体视。
  • 微单眼视策略保留了良好远视力,但低对比度视力和主观视觉现象存在妥协。

研究设计与样本

  • 前瞻性、随机、对照、患者与检查者设盲的单中心临床试验。
  • 患者随机接受双眼微单眼视(非主导眼目标-0.75 D)或正视目标,植入折射型扩展景深人工晶状体DEN00V(Tecnis PureSee)。
  • 术后3个月评估双眼裸眼及矫正远视力、裸眼中距和近视力、低对比度视力、离焦曲线、立体视及患者报告结局(PRSIQ、AIOLIS)。
  • 110眼(55例参与者)完成随访。

主要发现

  • 双眼裸眼远视力:微单眼视组-0.02 ± 0.07 logMAR,正视组-0.05 ± 0.07 logMAR(平均差0.03 logMAR;95%CI -0.01至0.07;P = .14)。
  • 双眼矫正远视力:微单眼视组-0.05 ± 0.06 logMAR,正视组-0.09 ± 0.08 logMAR(平均差0.04 logMAR;95%CI -0.01至0.09;P = .06)。
  • 双眼裸眼中距视力:微单眼视组0.06 ± 0.08 logMAR,正视组0.10 ± 0.09 logMAR(平均差-0.04 logMAR;95%CI -0.09至0.01;P = .09)。
  • 双眼裸眼近视力:微单眼视组0.20 ± 0.07 logMAR,正视组0.23 ± 0.09 logMAR(平均差-0.03 logMAR;95%CI -0.08至0.02;P = .18)。
  • 低对比度视力在正视组显著更优:5%对比度(0.10 logMAR;95%CI 0.04至0.16;P < .001)和1.25%对比度(0.10 logMAR;95%CI 0.03至0.17;P = .01),经Holm-Bonferroni校正。

关键数值与推荐

  • 微单眼视组非主导眼目标屈光度为-0.75 D。
  • 双眼离焦曲线经多重比较校正后无统计学显著差异。
  • 两组立体视均保留且无显著差异。
  • 患者报告结局显示两组远距和中距满意度高、眼镜依赖低;微单眼视组近距眼镜依赖稍低但眩光增加。

临床怎么用

  • 对于接受双眼白内障手术并植入DEN00V的患者,微单眼视或正视目标均可考虑,两者均提供优异的远距和中距视力。
  • 若优先考虑低对比度视力,正视目标可能更优;若希望稍降低近距眼镜依赖,可考虑微单眼视但需告知眩光增加风险。

局限性

  • 单中心研究,完成随访样本为55例(110眼)。
  • 随访时间为术后3个月。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare visual performance, low-contrast visual acuity, stereopsis, and patient-reported outcomes of a refractive Extended Depth of Field (EDF) intraocular lens (IOL) implanted targeting mini-monovision or emmetropia target. DESIGN: Prospective, randomized, controlled, patient- and examiner-masked single-center clinical trial. METHODS: Sixty patients (120 eyes) undergoing bilateral cataract surgery at the Hanusch Hospital (Vienna, Austria) received the refractive EDF intraocular lens (DEN00V, Tecnis PureSee). Patients were randomized to receive either binocular mini-monovision (MMV), targeting -0.75 D in the nondominant eye, or emmetropia (EMM). Binocular uncorrected and corrected distance visual acuity (UDVA/CDVA), uncorrected intermediate (UIVA) and near visual acuity (UNVA), low contrast visual acuity, defocus curves, stereopsis, and patient-reported outcomes (PRSIQ, AIOLIS) were evaluated three months postoperatively. RESULTS: Binocular UDVA and CDVA were excellent and did not differ significantly between groups (110 eyes; 55 participants completed follow-up), -0.02 ± 0.07 logMAR for MMV and -0.05 ± 0.07 logMAR for EMM (mean difference: 0.03 logMAR; 95% Confidence Interval -0.01 to 0.07; P = .14) and -0.05 ± 0.06 logMAR for MMV and -0.09 ± 0.08 logMAR for EMM (0.04 logMAR; 95% CI: -0.01 to 0.09; P = .06), respectively. Binocular UIVA was 0.06 ± 0.08 logMAR for MMV and 0.10 ± 0.09 logMAR for EMM (-0.04 logMAR; 95% CI: -0.09 to 0.01; P = .09) and UNVA 0.20 ± 0.07 logMAR for MMV and 0.23 ± 0.09 logMAR for EMM (-0.03 logMAR; 95% CI: -0.08 to 0.02; P = .18). Low contrast visual acuity was statistically significantly better in the emmetropia group at 5% (0.10 logMAR; 95% CI: 0.04 to 0.16; P < .001) and 1.25% (0.10 logMAR; 95% CI: 0.03 to 0.17; P = .01) levels of contrast after Holm-Bonferroni correction. Binocular defocus curves were comparable with no statistically significant differences after correction for multiple comparisons. Stereopsis was preserved in both groups without significant differences. Patient-reported outcomes demonstrated high satisfaction and low spectacle dependence in both groups for far and intermediate distance, with slightly reduced near spectacle dependence but increased glare in the mini-monovision group. CONCLUSIONS: Bilateral implantation of the DEN00V, a refractive EDF intraocular lens, in a mini-monovision or emmetropia setting, provides excellent distance and intermediate vision with good low-contrast visual acuity and preserved stereopsis. Applying a mini-monovision strategy preserved good distance vision with compromises in low-contrast visual acuity and subjective visual phenomena.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Zeilinger J, Ruiss M, Pilwachs C, et al. Visual Performance of a Refractive Extended Depth of Field Intraocular Lens in Monovision and Emmetropic Settings. Am J Ophthalmol. 2026. PMID: 42731773. doi:10.1016/j.ajo.2026.09.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。