硅水凝胶多焦点软镜矫正老视的非劣效性临床研究
本研究为前瞻性随机开放平行对照多中心非劣效试验,纳入180名老视受试者随机配戴新型硅水凝胶或传统水凝胶多焦点软镜。戴镜1周两组有效率均为100.0%,率差0.00%(95%CI -4.23%~4.09%),非劣效成立。新型镜片在舒适度、主观体验及短期眼表保护方面优于对照镜片。
要点
- 戴镜1周WOCF填补后两组有效率均100.0%,率差0.00%(95%CI -4.23%~4.09%),非劣效成立。
- 试验组戴镜1周主观中远视力「极佳」比例50.0% vs 36.8%(P=0.047),舒适度及镜片清洁度优于对照组。
- 两组矫正视力均正常且无显著差异,接触镜矫正视力较框架镜略低约0.03~0.06。
核心结论
- 新型硅水凝胶多焦点软镜矫正老视的有效性不劣于传统水凝胶镜片,安全性良好。
- 新型镜片在配戴舒适度、主观体验及短期眼表保护方面优于对照镜片,可作为老视人群的有效矫正选择。
研究设计与样本
- 前瞻性、随机、开放、平行对照、多中心非劣效临床试验,5家中心筛选195名≥40岁老视受试者,纳入180名按1∶1随机分组。
- 试验组配戴samfilcon A硅水凝胶多焦点软镜(n=90),对照组配戴polymacon水凝胶多焦点软镜(n=90),均为月抛型日戴。
- 主要终点为戴镜1周时双眼矫正远视力≥4.9且近视力≥4.7的戴镜有效率,非劣效界值为-10%。
主要发现
- 全分析集177名(试验组87名、对照组90名),年龄(47.1±4.66)岁,男性33名,女性144名。
- WOCF填补后戴镜1周两组有效率均为100.0%,率差0.00%(95%CI -4.23%~4.09%);敏感性分析两组有效率96.6%与96.7%,CMH校正率差-0.00%(P=0.991)。
- 各访视点两组双眼矫正视力均在正常范围且无显著差异(均P>0.05),接触镜矫正视力较框架镜略低约0.03~0.06。
- 试验组戴镜1周主观中远视力「极佳」比例50.0% vs 36.8%(P=0.047),舒适度在1周和1个月优于对照组(均P<0.05),镜片清洁度在戴镜当天和1周优于对照组(均P<0.05)。
- 低近附加受试者戴镜1周总主观评分优于高近附加者[2.0(0.0,4.0)vs 4.0(2.0,5.0),P=0.004],3个月时差异消失;试验组戴镜1个月TBUT下降幅度小于对照组(P<0.05),1周和1个月角膜荧光素染色0级比例高于对照组(均P<0.05),3个月时差异消失。
关键数值与推荐
- 主要终点戴镜有效率定义:双眼矫正远视力≥4.9且近视力≥4.7。
- 非劣效界值预设为-10%。
- 未发生器械相关严重不良事件,两组不良事件发生率差异无统计学意义。
临床怎么用
- 新型硅水凝胶多焦点软镜可作为老视人群的有效矫正选项,尤其适合关注舒适度和短期眼表保护者。
- 低近附加受试者短期主观评分更优,高近附加者3个月时差异消失,验配时需结合近附加度数评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To evaluate the efficacy and safety of a novel silicone hydrogel multifocal soft contact lens for presbyopia correction, and to verify its non-inferiority compared with a conventional hydrogel multifocal contact lens. Methods: This was a prospective, randomized, open-label, parallel-group, multicenter non-inferiority clinical trial. From October 2024 to July 2025, 195 presbyopic subjects aged ≥40 years with near add power of +0.75 to +2.50 D were screened at 5 centers (Eye Hospital of Wenzhou Medical University, Eye & ENT Hospital of Fudan University, and Shenzhen Eye Hospital, Qingdao Eye Hospital of Shandong First Medical University, and Shanxi Eye Hospital Affiliated to Shanxi Medical University), and 180 were enrolled and randomized (computer-generated random number method) 1∶1 to the test group (samfilcon A silicone hydrogel multifocal soft contact lens, n=90) or the control group (polymacon hydrogel multifocal soft contact lens, n=90). Both type of lenses were monthly disposable for daily wear. Binocular corrected distance visual acuity (5 m) and near visual acuity (40 cm) were measured at each visit using a standard logarithmic visual acuity chart (5-point recording method). Subjective wearing experience was assessed by a validated acceptability questionnaire, and ocular surface status was evaluated via tear break-up time (TBUT) and corneal fluorescein staining. The primary endpoint was the wearing success rate at 1 week, defined as binocular corrected distance visual acuity ≥4.9 and near visual acuity ≥4.7. Missing values were imputed using the worst observation carried forward method. Rate differences and 95% confidence intervals (CI) were calculated by the Newcombe-Wilson method. Between-group comparisons were performed using Fisher exact test, independent-samples t test, or Wilcoxon rank-sum test. Sensitivity analysis was performed using the Cochran-Mantel-Haenszel method stratified by center. The non-inferiority margin was prespecified as -10%. Results: The full analysis set comprised 177 subjects (87 in the test group, 90 in the control group), with a mean age of (47.1±4.7) years, including 33 males and 144 females. After the data imputation, the wearing success rate at 1 week was 100.0% in both groups, with a rate difference of 0.00% (95%CI:-4.23% to 4.09%), meeting the non-inferiority criterion. Sensitivity analysis of raw data showed success rates of 96.6% and 96.7% in the test and control groups, respectively (adjusted rate difference -0.00%, P=0.991), consistent with the primary analysis. At all visits, binocular corrected visual acuities were within normal ranges in both groups, with no significant between-group differences (all P>0.05). Contact lens-corrected visual acuity was slightly lower than best spectacle-corrected visual acuity in both groups, with mean differences of approximately 0.03 to 0.06. The test group had a higher proportion of"excellent"subjective distance vision ratings at 1 week (50.0% vs. 36.8%, P=0.047), better comfort at 1 week and 1 month (both P<0.05), and better lens cleanliness at dispensing and 1 week (both P<0.05). Subjects with low add power had better total subjective scores at 1 week [2.0 (0.0, 4.0) vs. 4.0 (2.0, 5.0), P=0.004], with no significant difference at 3 months. At 1 month, the test group showed a smaller decrease in TBUT from baseline (P<0.05) and a higher proportion of grade 0 corneal fluorescein staining at 1 week and 1 month (both P<0.05); these differences disappeared by 3 months. No device-related serious adverse events occurred, and the incidence of adverse events did not differ significantly between groups. Conclusions: The novel silicone hydrogel multifocal soft contact lens is non-inferior to the conventional hydrogel lens in presbyopia correction, with a comparable safety profile and superior comfort, subjective experience, and short-term ocular surface protection. It can serve as an effective correction option for presbyopic populations. 目的: 评价新型硅水凝胶多焦点软性接触镜矫正老视的有效性与安全性,验证其相对于传统水凝胶多焦点接触镜的非劣效性。 方法: 本研究为前瞻性、随机、开放、平行对照、多中心非劣效临床试验。2024年10月至2025年7月于5家中心(温州医科大学附属眼视光医院、复旦大学附属眼耳鼻喉科医院、深圳市眼科医院、山东第一医科大学附属青岛眼科医院和山西省眼科医院)筛选195名年龄≥40岁、近附加+0.75~+2.50 D的老视受试者,纳入180名,按1∶1随机(计算机生成随机数字法)分配至试验组(samfilcon A硅水凝胶多焦点软性接触镜,90名)和对照组(polymacon水凝胶多焦点软性接触镜,90名),均为月抛型日戴。采用标准对数视力表(5分记录法)测量各访视点双眼接触镜矫正远视力(5 m)和近视力(40 cm),通过主观可接受性问卷评估配戴体验,以泪膜破裂时间和角膜荧光素染色评估眼表状态。主要终点为戴镜1周时双眼矫正远视力≥4.9且近视力≥4.7的戴镜有效率。缺失值采用最差观测值结转法(WOCF)填补,率差及95%置信区间(CI)采用Newcombe-Wilson法,组间比较采用Fisher确切概率法、成组t检验或秩和检验,敏感性分析采用考虑中心因素的CMH法;非劣效界值为-10%。 结果: 全分析集177名(试验组87名、对照组90名),年龄(47.1±4.66)岁,其中男性33名,女性144名。戴镜1周WOCF填补后,两组戴镜有效率均为100.0%,率差为0.00%(95%CI:-4.23%~4.09%),非劣效成立;敏感性分析两组有效率分别为96.6%与96.7%,CMH校正率差-0.00%(P=0.991),结论一致。各访视点两组双眼矫正视力均在正常范围,差异无统计学意义(均P>0.05);两组接触镜矫正视力较框架镜略低,差值约0.03~0.06。试验组戴镜1周主观中远视力“极佳”评级比例优于对照组(50.0%和36.8%,P=0.047),舒适度在戴镜1周和1个月时优于对照组(均P<0.05),镜片清洁度在戴镜当天和1周时优于对照组(均P<0.05)。低近附加受试者戴镜1周总主观评分优于高近附加者[2.0(0.0,4.0)和4.0(2.0,5.0),P=0.004],3个月时差异消失。戴镜1个月时试验组泪膜破裂时间下降幅度小于对照组(P<0.05),戴镜1周和1个月时角膜荧光素染色0级比例均高于对照组(均P<0.05),3个月时差异消失。未发生器械相关严重不良事件,两组不良事件发生率差异无统计学意义。 结论: 新型硅水凝胶多焦点软性接触镜矫正老视的有效性不劣于传统水凝胶镜片,安全性良好,且在配戴舒适度、主观体验及短期眼表保护方面优于对照镜片,可作为老视人群的有效矫正选择。.
引用
- Jin WQ, Li SF, Qu XM, et al. [Clinical study of silicone hydrogel multifocal soft contact lenses for correction of presbyopia]. Zhonghua Yan Ke Za Zhi. 2026. PMID: 42552118. doi:10.3760/cma.j.cn112142-20260510-00192
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。