文献速递角膜与眼表疾病

激光扫描共聚焦与白光干涉术三维地形图评估FECD的Descemet膜

Three-dimensional topography of Descemet's membrane in Fuchs endothelial corneal dystrophy using laser scanning confocal microscopy and white-light interferometry.
PubMed 文献 · Br J Ophthalmol · 2026-09-22

该研究利用结合激光扫描共聚焦成像与白光干涉术的三维显微镜,对38例FECD患者和4例健康供体的Descemet膜进行定量地形表征,发现FECD组表面粗糙度Sa显著高于对照组,并识别出中央、旁中央和外周三个不同区域及径向结构特征。

要点

  • 白光干涉术可全视野映射8mm直径Descemet膜,垂直分辨率达纳米级,约2小时/样本。
  • FECD组Sa中位数0.571±0.259 µm,显著高于对照组0.239±0.161 µm(p=0.0018)。
  • FECD中识别三个区域:中央(guttae埋于后纤维层,Sa 0.442±0.112 µm)、旁中央(大暴露guttae,Sa 0.562±0.170 µm,p=0.0423)、外周(无融合guttae,Sa 0.261±0.143 µm,p<0.0001)。

核心结论

  • 结合白光干涉术和共聚焦显微镜可对FECD的Descemet膜进行无标记高分辨率表面表征,提供定量指标比较组织学亚型。
  • 研究支持FECD中径向结构组织占主导地位。

研究设计与样本

  • 研究纳入38例接受内皮角膜移植术的FECD患者的Descemet膜和4例健康供体。
  • 标本平贴于载玻片干燥后,使用VK-X3000系统(KEYENCE)分析。
  • 低倍(×10)白光干涉模式(轴向分辨率0.01 nm)拼接重建全样本,高倍(×20至×150)共聚焦模式(轴向分辨率12 nm)进行详细结构分析。
  • 生成三维高度图计算标准化表面粗糙度参数,按空间组织和高度轮廓分类guttae等特征。

主要发现

  • 白光干涉术实现全视野映射8 mm直径Descemet膜,垂直分辨率约纳米级,约2小时/样本。
  • FECD组表面粗糙度Sa中位数±IQR为0.571±0.259 µm,对照组为0.239±0.161 µm,p=0.0018。
  • FECD中识别三个区域:中央(guttae埋于后纤维层;Sa 0.442±0.112 µm)、旁中央(大暴露guttae;Sa 0.562±0.170 µm;p=0.0423)和外周(无融合guttae;Sa 0.261±0.143 µm;p<0.0001)。
  • 共聚焦三维成像显示Descemet膜中径向条纹、隆起和沟槽,中央融合guttae及融合或埋藏结构。

关键数值与推荐

  • FECD组与对照组表面粗糙度Sa比较:0.571±0.259 µm vs 0.239±0.161 µm,p=0.0018。
  • FECD中央区Sa为0.442±0.112 µm,旁中央区为0.562±0.170 µm(p=0.0423),外周区为0.261±0.143 µm(p<0.0001)。
  • 白光干涉模式轴向分辨率0.01 nm,共聚焦模式轴向分辨率12 nm。

临床怎么用

  • 该技术可无标记、高分辨率地表征FECD的Descemet膜,提供定量表面粗糙度指标。
  • 有助于比较FECD组织学亚型,并支持径向结构组织在FECD中的主导地位。

局限性

  • 样本量有限(38例FECD和4例健康供体),可能影响结果的普遍性。
  • 标本需平贴干燥处理,可能改变天然组织结构。
  • 每样本约2小时的分析时间可能限制高通量应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate the potential of a three-dimensional microscope combining laser scanning confocal imaging and white-light interferometry for quantitative topographic characterisation of Descemet's membrane (DM) in Fuchs endothelial corneal dystrophy (FECD). METHODS: Descemet's membranes were collected from 38 FECD patients undergoing endothelial keratoplasty and four healthy donors. After flat-mounting on glass slide and drying, specimens were analysed using the VK-X3000 system (KEYENCE). Entire samples were reconstructed by image stitching at low magnification (×10) in white-light interferometry mode (0.01 nm axial resolution). Higher magnifications (×20 to ×150) in confocal mode (12 nm axial resolution) enabled detailed structural analysis. Three-dimensional height maps were generated to calculate standardised surface roughness parameters. Guttae and other DM features were classified according to spatial organisation and elevation profiles. RESULTS: White-light interferometry enabled full-field mapping of whole 8 mm diameter DMs with nanometric vertical resolution (~2 hours/sample). Surface roughness (Sa) was higher in FECD than in controls (median±IQR: 0.571±0.259 µm vs 0.239±0.161 µm; p=0.0018). In FECD, three zones were identified: centre (guttae buried in the posterior fibrillar layer; Sa 0.442±0.112 µm), paracentre (large uncovered guttae; Sa 0.562±0.170 µm; p=0.0423) and outer zone (no confluent guttae; Sa 0.261±0.143 µm; p<0.0001). Confocal three-dimensional (3D) imaging revealed radial striae, embossments and furrows in the DM, confluent central guttae and fused or buried structures. CONCLUSIONS: Combining white-light interferometry and confocal microscopy enables label-free, high-resolution surface characterisation of DM in FECD, providing quantitative metrics to compare histological subtypes and supporting the predominance of radial structural organisation.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Maurin C, Poinard S, Travers G, et al. Three-dimensional topography of Descemet's membrane in Fuchs endothelial corneal dystrophy using laser scanning confocal microscopy and white-light interferometry. Br J Ophthalmol. 2026. PMID: 42586765. doi:10.1136/bjo-2026-330189

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。