角膜后前表面曲率半径比对标准K与全角膜曲率计算人工晶状体度数预测准确性的影响
该回顾性研究纳入1314眼,按角膜后前表面曲率半径比(PAR)分层,比较标准角膜曲率(K)与全角膜曲率(TK)在Barrett Universal II和Kane公式下预测人工晶状体度数的准确性。PAR与K和TK预测误差的差异独立相关;TK在低PAR眼产生近视漂移、高PAR眼产生远视漂移,中PAR眼变化极小;各PAR亚组中位绝对误差相当,高PAR亚组BUII公式TK降低±0.50D内比例。
要点
- PAR是K与TK预测误差差异的独立相关因素(P<.001)。
- 低PAR眼TK产生-0.10D近视漂移,高PAR眼+0.14D远视漂移。
- 高PAR亚组BUII公式TK降低±0.50D内比例(79.9% vs 75.4%)。
核心结论
- PAR是K与TK折射预测差异的独立相关因素,TK主要引起PAR依赖的系统性方向性折射偏移而非普遍提高准确性。
研究设计与样本
- 回顾性评估IOL度数计算准确性,纳入1314例患者1314眼,均行无缝线超声乳化联合单焦点IOL植入,术前用IOLMaster 700行生物测量。
- 按PAR分为低(<25th百分位)、中(25th-75th百分位)、高(>75th百分位)三个亚组,用BUII和Kane公式分别以K和TK计算预测误差。
主要发现
- PAR与BUII和Kane公式中K与TK预测误差的差异独立相关(均P<.001)。
- 与标准K相比,TK在低PAR眼产生一致的近视漂移(两公式均-0.10D,均P<.001),在高PAR眼产生远视漂移(两公式均+0.14D,均P<.001),中PAR眼变化极小。
- 各PAR亚组中K与TK的中位绝对误差相当。
- 高PAR亚组中,BUII公式采用TK显著降低±0.50D内眼比例(79.9% vs 75.4%,P=.041),Kane公式无显著差异。
关键数值与推荐
- PAR分组界值:低<25th百分位,中25th-75th百分位,高>75th百分位。
- 预测误差绝对阈值:±0.50D。
- 低PAR眼TK近视漂移-0.10D(两公式均P<.001),高PAR眼TK远视漂移+0.14D(两公式均P<.001)。
- 高PAR亚组BUII公式±0.50D内比例TK 79.9% vs K 75.4%(P=.041)。
临床怎么用
- PAR可作为选择K或TK计算的临床生物标志物,而非对所有眼常规使用TK。
- 低PAR眼使用TK需注意近视漂移,高PAR眼使用TK需注意远视漂移。
- 高PAR眼选用BUII公式时TK可能降低±0.50D内比例,需权衡。
局限性
- 回顾性研究设计。
- 仅纳入单焦点IOL和特定公式(BUII、Kane)。
- 原文未报告随访时长及更长期屈光结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the predictive accuracy of standard keratometry (K) and total keratometry (TK) for intraocular lens (IOL) power calculation across eyes stratified by the posterior-to-anterior corneal radius ratio (PAR). DESIGN: Retrospective evaluation of IOL power calculation accuracy. METHODS: A total of 1314 eyes of 1314 patients who underwent uneventful phacoemulsification with monofocal IOL implantation were enrolled. Preoperative biometry was performed with the IOLMaster 700 (Carl Zeiss Meditec). Eyes were divided into three subgroups according to the PAR: low (<25th percentile), medium (25th-75th percentiles), and high (>75th percentile). Refractive prediction errors (PEs) were calculated with the Barrett Universal II (BUII) and Kane formulas, using both K and TK values. Main outcome measures were PE, median absolute error, and the proportions of eyes within predefined absolute PE thresholds. RESULTS: PAR was independently associated with the discrepancy between K- and TK-based PEs in both the BUII and Kane formulas (both P < .001). Compared with standard K, TK produced a consistent myopic shift in eyes with low PAR (-0.10 D for both formulas; both P < .001) and a hyperopic shift in eyes with high PAR (+0.14 D for both formulas; both P < .001), whereas only minimal changes were observed in eyes with medium PAR. Despite these systematic directional shifts, median absolute error remained comparable between K- and TK-based calculations across all PAR subgroups. In the high PAR subgroup, incorporation of TK significantly reduced the proportion of eyes within ±0.50 D of target refraction for the BUII formula (79.9% vs 75.4%, P = .041), whereas no significant difference was observed for the Kane formula. CONCLUSIONS: PAR is an independent factor associated with the discrepancy between K- and TK-based refractive predictions. Rather than uniformly improving refractive accuracy, TK primarily induces systematic, PAR-dependent directional refractive shifts. These findings suggest that PAR may serve as a clinically useful biomarker for selecting between K- and TK-based calculations instead of supporting the routine use of TK in all eyes.
引用
- Yang Z, Yang FM, Meng ZQ, et al. Influence of the Corneal Posterior-to-Anterior Radius Ratio on Intraocular Lens Power Prediction Using Standard and Total Keratometry. Am J Ophthalmol. 2026. PMID: 42600885. doi:10.1016/j.ajo.2026.08.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。