文献速递眼外伤眼底病与葡萄膜炎

眼内异物:临床表现、诊断挑战与管理策略的系统综述与荟萃分析

Intraocular foreign bodies: a systematic review and meta-analysis of clinical manifestations, diagnostic challenges and management strategies.
PubMed 文献 · Br J Ophthalmol · 2026-08-04

该研究系统检索并荟萃分析了2000年至2025年间有关眼内异物(IOFB)的文献,共纳入59项研究、4289例患者。视力下降、眼痛和眼内炎症是最常见表现,CT诊断准确性最高,经平坦部玻璃体切除术为主要术式。早期取出IOFB与更好的视力恢复和更少并发症相关。

要点

  • 视力下降(78%)、眼痛(42%)和眼内炎症(36%)是IOFB最常见临床表现。
  • CT诊断准确性最高(91.2%),超声敏感度为83.6%,尤其在屈光介质混浊时。
  • 早期(≤24小时)取出IOFB与更好的视力恢复和更少并发症相关。

核心结论

  • 早期诊断和及时手术干预对优化眼内异物患者的预后至关重要。
  • CT和经平坦部玻璃体切除术仍是IOFB管理的核心手段,延迟干预会增加严重并发症风险。

研究设计与样本

  • 共纳入59项研究、4289例患者,其中42项研究符合定量荟萃分析条件,采用随机效应模型合并数据。

主要发现

  • 视力下降(78%)、眼痛(42%)和眼内炎症(36%)是最常见的临床表现。
  • 眼内炎发生率为12.4%,视网膜脱离发生率为9.8%。
  • 65.7%的患者获得良好视力结局(最佳矫正视力BCVA≥20/40)。
  • CT诊断准确性最高(91.2%),超声敏感度为83.6%,尤其在屈光介质混浊时。
  • 经平坦部玻璃体切除术是主要手术方式,总体手术成功率为96.5%。

关键数值与推荐

  • 良好视力结局定义为最佳矫正视力BCVA≥20/40,65.7%的患者达到该标准。
  • CT诊断准确性为91.2%,超声敏感度为83.6%。
  • 经平坦部玻璃体切除术总体手术成功率为96.5%。
  • 早期IOFB取出定义为≤24小时,与更好的视力恢复和更少并发症相关。

临床怎么用

  • 对疑似IOFB的眼外伤患者应尽早行CT检查以明确诊断。
  • 确诊后应尽早(≤24小时)取出异物,以改善视力恢复并减少并发症。
  • 经平坦部玻璃体切除术可作为IOFB取出的主要手术方式。

局限性

  • 需要标准化诊疗方案和前瞻性多中心研究来强化证据并改善患者管理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: Retained intraocular foreign bodies (IOFBs) are important causes of vision-threatening ocular trauma and preventable visual impairment. This systematic review and meta-analysis evaluated the clinical manifestations, diagnostic approaches, surgical management and visual outcomes associated with IOFBs. METHODS: A systematic search of PubMed, Embase, Scopus and Web of Science identified studies published between 1 January 2000 and 30 November 2025. Eligible studies reporting clinical presentation, imaging findings, management strategies or outcomes of retained IOFBs were included. Data were synthesised using a random-effects meta-analysis model. RESULTS: A total of 59 studies involving 4289 patients were included of which 42 were eligible for quantitative meta-analysis. Reduced visual acuity (78%), ocular pain (42%) and intraocular inflammation (36%) were the most common clinical manifestations. Endophthalmitis occurred in 12.4% and retinal detachment in 9.8% of cases. Favourable visual outcomes (Best Corrected Visual Acuity-BCVA≥20/40) were achieved in 65.7% of patients. CT demonstrated the highest diagnostic accuracy (91.2%), while ultrasonography showed 83.6% sensitivity particularly in media opacity. Pars plana vitrectomy was the predominant surgical approach, with an overall surgical success rate of 96.5%. Early IOFB removal (≤24 hours) was associated with improved visual recovery and reduced complications. CONCLUSIONS: Early diagnosis and timely surgical intervention are critical for optimising outcomes in retained IOFBs. CT and pars plana vitrectomy remain central to management, while delayed intervention increases the risk of severe complications. Standardised protocols and prospective multicentre studies are needed to strengthen evidence and improve patient care.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Priya P, Mishra N, Yadav NK, et al. Intraocular foreign bodies: a systematic review and meta-analysis of clinical manifestations, diagnostic challenges and management strategies. Br J Ophthalmol. 2026. PMID: 42552100. doi:10.1136/bjo-2026-329418

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。