文献速递小儿眼科与斜弱视

弱视儿童在平板自适应视力评估中的心理测量表现

Psychometric Performance of Children With Amblyopia During a Tablet-Based Adaptive Visual Acuity Assessment.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2026-01-01

AIM-VA成功检出弱视眼间视力差,单参数模型重测无显著偏倚,但弱视组logMAR值较Snellen系统性偏低。

要点

  • AIM-VA可检出弱视儿童近视力眼间差异。
  • 单参数AIM-VA重测无显著偏倚,变异度可比。
  • 弱视组AIM-VA的logMAR估值较Snellen系统性偏低。

核心结论

  • AIM-VA成功检出弱视近视力眼间视力差,单参数模型无重测偏倚且变异度可比。

主要发现

  • 弱视组眼间视力差在AIM-VA和Snellen检查中均显著大于对照组。
  • 单参数AIM-VA重测重复性与此前报道相当,弱视组尤然,且无显著重测偏倚(P > 0.05)。
  • 弱视组AIM-VA的logMAR估值较Snellen系统性偏低(P = 0.002),可能反映测试距离与任务差异。
  • 探索性分析显示各组较浅的心理测量斜率均与较大噪声值相关,屈光性弱视较斜视性弱视参数协变性更强。

临床怎么用

  • AIM-VA作为自适应自施测任务,可能成为弱视管理的有效工具。

局限性

  • 探索性心理测量参数作为功能缺陷附加指标的价值及弱视亚型表型差异尚需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Visual acuity is a key metric for the diagnosis of amblyopia. Here, we introduce a self-administered near visual acuity (VA) test using the Angular Indication Measurement paradigm (AIM-VA) and evaluate it in children with and without amblyopia. METHODS: Thirty-five children (age range, 5-16 years; 20 males) with (n = 22) and without (n = 13) amblyopia monocularly completed the AIM-VA twice within the same day and a Snellen-VA test. The AIM-VA presented three 4 × 4 charts of Landolt-C optotypes that adaptively varied in size and had randomized gap orientations. Orientation report errors as a function of optotype size were fit with a one-parameter (VA) model or a three-parameter (VA, slope, and response error) model. Bland-Altman analysis assessed test-retest repeatability and intertest agreement with Snellen-VA. Linear correlations and leave-one-out analyses explored relationships between psychometric parameters across groups and amblyopia subtypes. RESULTS: Interocular acuity difference (IOD) was significantly larger in children with amblyopia than in controls for both AIM-VA and Snellen-VA. The one-parameter AIM-VA yielded repeatability comparable to previous reports, particularly in the amblyopic group, and showed no significant test-retest bias (P > 0.05). However, there was a systematic mean bias of lower logMAR estimates relative to Snellen-VA in the amblyopic group (P = 0.002), likely reflecting the difference in testing distance and task. Exploratory analysis revealed that shallower psychometric slopes were consistently associated with larger noise values across groups, with stronger parameter covariance in refractive than strabismic amblyopia. CONCLUSIONS: AIM-VA successfully detected amblyopic near-vision IOD. The one-parameter AIM-VA model showed no retest bias and comparable variance in this pediatric population. Exploratory psychometric parameters showed promise as additional indicators of functional deficits, with potential phenotypical differences between amblyopia subtypes warranting further investigation. AIM-VA is an adaptive, self-administered task that may be an effective tool for managing amblyopia.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Skerswetat J, Ahmed Z, Chaudhry N, et al. Psychometric Performance of Children With Amblyopia During a Tablet-Based Adaptive Visual Acuity Assessment. Invest Ophthalmol Vis Sci. 2026. PMID: 42405674. doi:10.1167/iovs.67.8.12

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。