该体外研究比较了聚维酮碘(PI)与氯己定(CHX)对34株内眼炎临床分离株的抗菌效力,并在角膜上皮组织模型中评估了细胞活力和IL-8炎症反应。结果显示PI在多数分离株中抑菌圈更广,但CHX处理后的角膜上皮活力更高、炎症反应更低。

要点

  • PI 5%和10%对多数内眼炎分离株的抑菌圈显著宽于CHX,但CHX对铜绿假单胞菌更有效。
  • 在健康及表皮葡萄球菌感染角膜模型中,CHX组活细胞比例(71%-100%)高于PI组(9%-17%)。
  • PI处理组IL-8水平更高,CHX引发的炎症反应轻微。

核心结论

  • PI与CHX在体外均具广谱抗微生物活性,PI对多数分离株抗菌活性更强,CHX则与更高的角膜上皮活力和更低的所测细胞因子炎症反应相关。

研究设计与样本

  • 采用孔扩散法检测PI(5%、10%,另测0.025%、1%)与CHX(0.05%、0.1%)对34株微生物分离株(含革兰阳性菌、革兰阴性菌和真菌)的抑菌圈。
  • 在未感染及表皮葡萄球菌感染的角膜上皮组织模型中,用MTT法评估细胞活力,用酶联免疫吸附试验在多个时间点定量IL-8。

主要发现

  • PI 5%和10%在多数分离株中抑菌圈显著宽于CHX(P < 0.05),但CHX对铜绿假单胞菌效力更强。
  • PI 0.025%未见抑菌作用。
  • CHX处理组在健康和感染模型中活细胞比例更高(71%-100%),PI组为9%-17%。
  • PI处理组织IL-8水平更高,CHX引发炎症反应轻微。

关键数值与推荐

  • PI 5%和10%对多数分离株抑菌圈显著大于CHX(P < 0.05)。
  • CHX组角膜组织活细胞比例为71%-100%,PI组为9%-17%。
  • PI 0.025%无抑菌作用。

临床怎么用

  • 结果提示选择眼内手术或眼内炎预防用消毒剂时,需在PI的广谱抗菌优势与CHX的眼表毒性较低之间权衡,具体应用仍需进一步临床研究验证。

局限性

  • 研究为体外实验,采用孔扩散法和角膜上皮组织模型,样本为34株分离株,结论外推至活体临床实践需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the antimicrobial efficacy and ocular surface toxicity of two antiseptic agents: povidone-iodine (PI) and chlorhexidine gluconate (CHX) against clinical endophthalmitis isolates and to perform preliminary assessments of epithelial viability and inflammatory cytokine response following antiseptic exposure in a corneal tissue model. METHODS: A well diffusion assay was used to assess inhibition zones of PI (5% and 10%) and CHX (0.05% and 0.1%) against 34 microbial isolates, including Gram-positive and Gram-negative bacteria and fungi. Additional testing was conducted using lower concentrations of PI (0.025% and 1%). Corneal epithelial tissue models, both uninfected and infected with Staphylococcus epidermidis, were treated with two antiseptic agents. Cell viability was assessed by MTT assay, and inflammatory response was evaluated by quantifying IL-8 via enzyme-linked immunosorbent assay at multiple time points. RESULTS: PI at 5% and 10% demonstrated statistically significant broader antimicrobial inhibition across most isolates compared to CHX (P < 0.05), although CHX had greater efficacy against P. aeruginosa. PI at 0.025% showed no inhibition. CHX-treated corneal tissue retained higher viability (greater percent of living cells) in both healthy and infected models (71%-100%) compared to PI (9%-17%). PI-treated tissue showed higher IL-8 proinflammatory cytokine levels, and CHX elicited minimal inflammatory response. CONCLUSIONS: PI and CHX demonstrated broad-spectrum antimicrobial activity in vitro, with PI exhibiting greater antimicrobial activity across most isolates. CHX was associated with higher corneal epithelial viability and a lower inflammatory response of measured cytokines.