文献速递白内障与屈光手术眼底病与葡萄膜炎

悬韧带松弛对伴视网膜色素变性白内障患者人工晶状体度数计算公式准确性的影响

Impact of Zonular Laxity on the Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Patients With Retinitis Pigmentosa.
PubMed 文献 · Am J Ophthalmol · 2026-07-25

本回顾性研究纳入104例视网膜色素变性(RP)患者的127只眼,评估12种人工晶状体(IOL)计算公式的预测准确性,并分析悬韧带松弛对屈光误差的影响。结果显示Cooke K6、BUII、Kane和EVO 2.0公式无系统偏差且平均绝对误差较低,而部分公式出现近视或远视漂移;悬韧带松弛可导致术后远视漂移,需根据悬韧带长度调整目标屈光度。

要点

  • Cooke K6、BUII、Kane和EVO 2.0公式在RP患者中预测准确性较高。
  • 悬韧带长度与预测误差正相关,术后前房加深介导此关联。
  • 悬韧带松弛眼易出现术后远视漂移,需个体化调整目标屈光度。

核心结论

  • Cooke K6、BUII、Kane和EVO 2.0公式在RP患者中表现出更高的预测准确性。
  • 悬韧带松弛导致术后远视漂移,临床应根据悬韧带长度微调目标屈光度。

研究设计与样本

  • 共纳入104例患者的127只眼,评估12种IOL计算公式的预测准确性。
  • 术前使用超声生物显微镜测量平均悬韧带长度(AZL)及悬韧带长度最大最小值之差(AZL(max-min))。
  • 采用多因素回归和中介分析探究与预测误差相关的因素。

主要发现

  • Cooke K6、BUII、Kane和EVO 2.0公式无系统偏差,平均绝对误差为0.50-0.51 D。
  • Hoffer Q、Hoffer QST、Holladay 1、LISA、SRK/T和T2公式显示近视漂移(-0.21至-0.12 D,P < .05)。
  • Pearl-DGS公式显示远视漂移(0.15 D,P = .009)。
  • AZL与预测误差呈正相关(β = 0.328,P = .019),由术后前房加深介导(P < .05)。
  • 对于AZL ≥ 1.8 mm或AZL(max-min) ≥ 1.0 mm的眼,多数公式显示远视漂移且屈光预测准确性降低。

关键数值与推荐

  • Cooke K6、BUII、Kane和EVO 2.0公式的平均绝对误差为0.50-0.51 D。
  • Hoffer Q、Hoffer QST、Holladay 1、LISA、SRK/T和T2公式的近视漂移范围为-0.21至-0.12 D(P < .05)。
  • Pearl-DGS公式的远视漂移为0.15 D(P = .009)。
  • AZL与预测误差的回归系数β = 0.328(P = .019)。
  • AZL ≥ 1.8 mm或AZL(max-min) ≥ 1.0 mm时,多数公式出现远视漂移。

临床怎么用

  • 在RP患者中优先选用Cooke K6、BUII、Kane或EVO 2.0公式以提高IOL度数预测准确性。
  • 术前评估悬韧带长度,对悬韧带松弛眼(AZL ≥ 1.8 mm或AZL(max-min) ≥ 1.0 mm)考虑调整目标屈光度以补偿术后远视漂移。

局限性

  • 回顾性研究设计可能引入选择偏倚。
  • 样本量有限(127只眼),结论需更大样本验证。
  • 未报告随访时长及公式计算的具体参数设置。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the performance of 12 intraocular lens (IOL) calculation formulas and investigate the impact of zonular laxity on refractive accuracy in patients with retinitis pigmentosa (RP). DESIGN: Retrospective study to compare formulas for IOL selection. METHODS: The study enrolled patients with RP who underwent phacoemulsification and IOL implantation between December 2018 and November 2025. The prediction accuracy of 12 formulas were evaluated. Preoperative average zonular length (AZL) and the difference between the maximum and minimum of zonular length (AZL(max-min)) were measured by ultrasound biomicroscopy. Multivariate regression and mediation analysis were conducted to explore the factors associated with prediction error. RESULT: A total of 127 eyes from 104 patients were included. The Cooke K6, BUII, Kane, and EVO 2.0 formulas showed no systematic bias and had lower mean absolute errors (0.50-0.51 D), whereas the Hoffer Q, Hoffer QST, Holladay 1, LISA, SRK/T, and T2 formulas showed myopic shifts (-0.21 to -0.12 D, P < .05) and Pearl-DGS displayed a hyperopic shift (0.15D, P = .009). AZL was positively correlated with PE (β = 0.328, P = .019), mediated by postoperative deepening of the anterior chamber (P < .05). For eyes with AZL ≥ 1.8 mm or AZL(max-min) ≥ 1.0 mm, most formulas showed hyperopic shift and reduced refractive prediction accuracy. CONCLUSION: The Cooke K6, BUII, Kane, and EVO 2.0 formulas showed higher predictive accuracy in patients with RP. As zonular laxity predisposes these eyes to a postoperative hyperopic shift, clinicians should fine-tune the target refraction according to zonular length in these eyes.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Tian Y, Zeng L, Zhang J, et al. Impact of Zonular Laxity on the Accuracy of Intraocular Lens Power Calculation Formulas in Cataract Patients With Retinitis Pigmentosa. Am J Ophthalmol. 2026. PMID: 42501957. doi:10.1016/j.ajo.2026.07.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。