多模态影像活体定量比较血管样条纹与新生血管性年龄相关性黄斑变性中Bruch膜改变
回顾性队列研究纳入抗VEGF负荷治疗后黄斑干燥的初治MNV眼,比较血管样条纹相关MNV与nAMD的ICGA和OCT特征。AS组MNV面积更大、晚期斑点状低荧光更常见、Bruch膜起伏更常见、Bruch膜反射率指数更高,提示Bruch膜钙化与机械不稳定相关改变,该指数有助于鉴别两者。
要点
- AS相关MNV较nAMD的MNV面积更大且晚期斑点状低荧光更常见。
- AS组Bruch膜起伏更常见,Bruch膜反射率指数显著高于nAMD。
- Bruch膜反射率指数鉴别AS相关MNV与nAMD的AUC为0.850。
核心结论
- AS相关MNV较nAMD呈现更大MNV面积、更常见晚期斑点状低荧光和Bruch膜起伏、更高Bruch膜反射率指数,可能反映Bruch膜钙化与机械不稳定相关改变。
- Bruch膜来源的ICGA和OCT生物标志物可能有助于表征AS病理生理并鉴别AS相关MNV与nAMD。
研究设计与样本
- 基线ICGA测量轴长校正MNV面积并识别晚期斑点状低荧光,黄斑干燥后OCT评估中央凹厚度、黄斑下脉络膜厚度、纤维血管性色素上皮脱离厚度、Bruch膜起伏及新定义的Bruch膜反射率指数。
- 采用组间比较和ROC分析评估Bruch膜相关生物标志物的诊断性能。
主要发现
- 有ICGA资料眼中,AS组MNV面积大于nAMD组(5.34 ± 3.29 mm2 vs 3.45 ± 1.22 mm2,P = .005)。
- AS组晚期斑点状低荧光发生率高于nAMD组(86.4% vs 18.8%,P < .001)。
- AS相关MNV组黄斑下脉络膜厚度低于nAMD组(166.0 ± 67.1 µm vs 217.2 ± 112.0 µm,P = .049)。
- AS组Bruch膜起伏更常见(24.0% vs 3.1%,P = .036),Bruch膜反射率指数更高(0.905 ± 0.148 vs 0.663 ± 0.169,P < .001)。
- 中央凹厚度和纤维血管性色素上皮脱离厚度组间无显著差异。
关键数值与推荐
- Bruch膜反射率指数鉴别AS相关MNV与nAMD的ROC曲线AUC为0.850(95%CI 0.754-0.946)。
- Bruch膜反射率指数最佳截断值为0.749,敏感度0.880,特异度0.656。
临床怎么用
- 对黄斑干燥后的MNV眼,可结合ICGA晚期斑点状低荧光与OCT Bruch膜起伏、Bruch膜反射率指数辅助区分AS相关MNV与nAMD。
- Bruch膜反射率指数以0.749为截断值时敏感度较高但特异度有限,解读时应结合其他影像特征。
局限性
- Bruch膜反射率指数为新定义指标,其诊断性能需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate Bruch's membrane (BrM) morphology in angioid streak (AS)-associated macular neovascularization (MNV) and neovascular age-related macular degeneration (nAMD) using multimodal imaging. DESIGN: Retrospective clinical cohort study. SUBJECTS: Treatment-naïve eyes with MNV secondary to AS or nAMD that achieved a dry macula after 3 loading intravitreal antivascular endothelial growth factor (VEGF) injections. METHODS: Baseline indocyanine green angiography (ICGA) images obtained before antiVEGF treatment were used to measure axial length-corrected MNV area and identify late-phase speckled hypofluorescent areas (SHA). Optical coherence tomography (OCT) images after dry macula achievement were used to assess central foveal thickness (CFT), subfoveal choroidal thickness (SCT), fibrovascular pigment epithelial detachment (PED) thickness, BrM undulation, and a newly defined BrM reflectivity index (BRI) calculated from intensity-normalized images. Group comparisons assessed BrM-related biomarker differences, and receiver operating characteristic (ROC) analyses evaluated their diagnostic performance. MAIN OUTCOME MEASURES: Differences in ICGA- and OCT-derived findings between AS-associated MNV and nAMD, including SHA, BrM undulation, and BRI, and the diagnostic performance of BRI and BrM undulation in differentiating AS-associated MNV from nAMD. RESULTS: Twenty-five eyes with AS and 32 eyes with nAMD were analyzed. Among eyes with available ICGA, MNV area was larger in AS than in nAMD (5.34 ± 3.29 mm2 vs 3.45 ± 1.22 mm2, P = .005), and late-phase SHA was more frequent in AS (86.4% vs 18.8%, P < .001). CFT and fibrovascular PED thickness did not differ significantly, whereas SCT was lower in AS-associated MNV than in nAMD (166.0 ± 67.1 µm vs 217.2 ± 112.0 µm; P = .049). BrM undulation was more common in the AS group (24.0% vs 3.1%, P = .036). BRI was higher in AS than in nAMD (0.905 ± 0.148 vs 0.663 ± 0.169, P < .001). The ROC curve for BRI showed an area under the curve of 0.850 (95% confidence interval, 0.754-0.946) with an optimal cutoff of 0.749, yielding 0.880 sensitivity and 0.656 specificity. CONCLUSIONS: Compared with nAMD, AS-associated MNV showed distinct ICGA and OCT features, including larger MNV area, more frequent late-phase SHA and BrM undulation, and higher BRI after antiVEGF loading. These findings may reflect BrM alterations associated with calcification and mechanical instability. BrM-derived ICGA and OCT biomarkers may help characterize AS pathophysiology and differentiate AS-associated MNV from nAMD.
引用
- Sakamoto T, Kadomoto S, Nakanishi Y, et al. In Vivo Quantification of Bruch's Membrane Changes in Angioid Streaks and Neovascular Age-related Macular Degeneration Using Multimodal Imaging. Am J Ophthalmol. 2026. PMID: 42448079. doi:10.1016/j.ajo.2026.07.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。