小鼠常规流出通路的高时空分辨率活体双光子成像:绿色活体成像
研究开发了绿色活体双光子成像方法,以亚微米空间分辨率和64.9毫秒/帧时间分辨率全面展示小鼠常规流出通路。观察到血小板经集液管短暂进出Schlemm管,房水向集液管汇聚且流速与模式存在差异,患者Schlemm管内也可见血小板。
要点
- 绿色活体成像可全面显示小鼠近端和远端常规流出通路。
- 血小板经集液管短暂进入和离开Schlemm管。
- Schlemm管内房水向集液管快速汇聚,流速和模式不均一。
核心结论
- 绿色活体成像能在亚微米空间分辨率和64.9毫秒/帧时间分辨率下全面展示小鼠常规流出通路。
研究设计与样本
- 使用Green、Prox1-reporter和mito-Dendra2小鼠进行活体双光子成像。
- 对人青光眼患者Schlemm管进行组织学评估。
主要发现
- 绿色活体成像展示了近周边静脉、集液管、Schlemm管和小梁网。
- Prox1-reporter小鼠中识别出带间隔的宽管状结构为Schlemm管。
- Schlemm管内观察到类似巨大空泡的结构和EGFP阳性囊泡流,囊泡被鉴定为血小板。
- 观察到血小板从近周边静脉进入Schlemm管并经集液管返回,以及房水向集液管快速汇聚。
- 定量分析提示Schlemm管内房水流速和流型存在差异,患者Schlemm管内也可见血小板。
临床怎么用
- 该成像方法可用于研究小鼠常规流出通路的精细结构和动态。
- 集液管可能参与房水的不均一动力学。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To develop an intravital imaging method that comprehensively shows the mouse conventional outflow pathway at high spatiotemporal resolution and to investigate the fine structures and dynamics within this pathway. METHODS: Intravital two-photon imaging was performed using Green, Prox1-reporter, and mito-Dendra2 mice. Schlemm's canal (SC) in human patients with glaucoma was histologically evaluated. RESULTS: The intravital two-photon imaging of Green mice ubiquitously expressing enhanced green fluorescent protein (EGFP) ("Green intravital imaging") demonstrated the perilimbal vein (PLV), collector channels (CCs), SC, and trabecular meshwork with and without a coverslip. A wide, tubular structure with septa was identified as SC in Prox1-reporter mice. Structures reminiscent of giant vacuoles and EGFP-positive vesicle flow were observed within SC. Based on the vesicle size, mitochondria in the vesicles, and platelet-specific intravital imaging findings, these EGFP-positive vesicles were identified as platelets. Moreover, platelet flow from the PLV into SC and from SC back to the PLV via CCs, as well as fast aqueous humor flow converging toward CCs, was observed. The quantitative analysis results suggested differences in aqueous flow velocity and flow patterns within SC. Platelets were also observed in SC of patients with glaucoma. CONCLUSIONS: Green intravital imaging comprehensively showed the proximal and distal conventional outflow pathway in mice at submicrometer spatial and 64.9-ms/frame temporal resolution, allowing observation of structures reminiscent of giant vacuoles. A subset of platelets transiently entered and exited SC via CCs. Within SC, aqueous humor exhibited fast flow converging toward the CCs, with differences in flow velocity and patterns. CCs may be involved in the heterogeneous dynamics of the aqueous humor.
引用
- Urahashi Y, Takihara Y, Higaki T, et al. Comprehensive, High-Spatiotemporal-Resolution Intravital Two-Photon Imaging of the Mouse Conventional Outflow Pathway: Green Intravital Imaging. Invest Ophthalmol Vis Sci. 2026. PMID: 42360097. doi:10.1167/iovs.67.6.53
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。