文献速递小儿眼科与斜弱视

Fresnel棱镜随注视方向变化的矫正误差量化及其对斜视管理的意义

Quantification of Gaze-Dependent Corrective Errors With Fresnel Prisms: Implications for Strabismus Management.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2026-01-01

研究将10Δ-40Δ的Fresnel棱镜安装于双轴旋转台,通过激光投影测量不同注视方向下的偏转误差,并比较两种棱镜配置(EPS与OPS)。结果显示矫正误差随棱镜度数、注视位置和应用方式变化,大于20Δ的棱镜出现显著且空间复杂的误差;EPS下水平注视向顶角移位导致过矫迅速增加,OPS下该梯度在水平轴反转。垂直注视还会产生非预期的垂直分量。

要点

  • Fresnel棱镜的矫正误差随棱镜度数、注视方向和配置方式(EPS/OPS)变化。
  • 大于20Δ的棱镜在周边注视位置出现显著且空间复杂的矫正误差。
  • 垂直注视不仅放大水平矫正效应,还产生非预期的垂直分量。

核心结论

  • Fresnel棱镜在 primary position 完全矫正斜视偏斜时,仍在 secondary 和 tertiary 注视位置引入非线性、随注视方向变化的矫正误差。
  • 认识这些光学特性可能有助于优化治疗效果并提高诊断准确性。

研究设计与样本

  • 实验研究:将Fresnel棱镜(10Δ-40Δ)安装于双轴旋转台,激光投射至100 cm切向屏测量偏转。
  • 测试两种配置:eyeward prism serration(EPS)和outward prism serration(OPS),水平及/或垂直旋转棱镜(±30°)。
  • 采用几何建模预测附着于眼镜片的棱镜偏转,并用Kriging插值生成注视野矫正误差等值线图。

主要发现

  • 矫正误差随棱镜度数、注视位置和应用方法(EPS vs OPS)变化(析因方差分析,P < 0.05)。
  • 大于20Δ的棱镜表现出显著且空间复杂的误差。
  • EPS配置下,水平注视向顶角移位导致过矫迅速增加,向基底移位导致欠矫。
  • OPS配置下,该梯度在水平轴上反转(P < 0.0001)。
  • 垂直注视不仅放大水平矫正效应,还产生非预期的垂直分量(垂直于主截面)。

临床怎么用

  • 临床选择Fresnel棱镜度数时需考虑注视方向相关的矫正误差,尤其使用大于20Δ的棱镜时。
  • 不同配置(EPS vs OPS)对水平注视误差梯度有相反影响,应用时需注意选择。
  • 垂直注视可能引入非预期的垂直偏转,评估和治疗中应予以关注。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Fresnel prisms are widely used to manage strabismus. Although prism power is typically selected based on the deviation in the primary gaze position, actual deflection varies with the gaze direction because the angle of incidence changes. This study quantified gaze-dependent corrective errors in the secondary and tertiary positions. METHODS: Fresnel prisms (10Δ-40Δ) were mounted on a two-axis rotation stage. Deflection was measured by projecting a laser spot onto a tangent screen 100 cm away while rotating the prisms horizontally and/or vertically (±30°). Two configurations were tested: eyeward prism serration (EPS) and outward prism serration (OPS). Geometric modeling was used to predict the deflection of a prism attached to a spectacle lens, and corrective errors across the gaze field were visualized as contour maps using Kriging interpolation. RESULTS: Corrective errors varied with prism power, gaze position, and application method (EPS vs. OPS; factorial ANOVA, P < 0.05). Prisms > 20Δ exhibited substantial, spatially complex errors. In the EPS configuration, horizontal gaze shifts toward the apex caused rapidly increasing overcorrection, whereas shifts toward the base led to undercorrection. In the OPS configuration, this gradient was reversed on the horizontal axis (P < 0.0001). Vertical gaze shifts not only amplified the horizontal corrective effects but also created unintended vertical components (perpendicular to the principal section). CONCLUSIONS: Fresnel prisms introduce nonlinear, gaze-dependent corrective errors despite the full correction of the strabismic deviation in the primary position. Recognition of these optical properties may help optimize therapeutic outcomes and enhance diagnostic accuracy.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Tanaka E, Morisawa S, Morizane Y, et al. Quantification of Gaze-Dependent Corrective Errors With Fresnel Prisms: Implications for Strabismus Management. Invest Ophthalmol Vis Sci. 2026. PMID: 42200767. doi:10.1167/iovs.67.5.68

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。