球周阻滞容积对眼压变化的影响:随机前瞻性研究
这项前瞻性随机对照研究将50只拟行眼内手术的眼随机分为4 mL与7 mL球周阻滞组,比较阻滞后及按摩后眼压变化与麻醉满意度。两组眼压变化无统计学差异,按摩后眼压均显著下降,7 mL组外科医生满意度评分显著更高。
要点
- 4 mL与7 mL球周阻滞后及按摩后眼压变化无统计学显著差异。
- 两组按摩后眼压均较阻滞后显著下降。
- 7 mL组外科医生麻醉满意度评分显著高于4 mL组。
核心结论
- 7 mL球周阻滞被显示为眼内手术中安全且更有效的方法。
研究设计与样本
- 前瞻性、对照、1:1随机、干预性研究,在两所门诊手术中心开展。
- 纳入18至79岁拟以球周阻滞为指定麻醉方式行眼内手术的患者,排除既往眼或眼眶手术史及角膜瘢痕或水肿眼。
- 共50只眼完成试验,4 mL组与7 mL组各25只眼。
主要发现
- 两组阻滞后眼压变化无统计学显著差异。
- 两组按摩后眼压变化无统计学显著差异,且两组眼压均在眼部按摩后显著下降。
- 7 mL组获得显著更高的外科医生满意度评分。
关键数值与推荐
- 球周阻滞容积随机分为4 mL或7 mL。
- 每例阻滞后由同一研究助理进行规范的2分钟手动按摩。
- 眼压用新校准的TonoPen在阻滞前、阻滞后即刻及手动按摩后测量,每个时间点测两次。
临床怎么用
- 在拟行眼内手术且选择球周阻滞的患者中,7 mL容积可提高外科医生麻醉满意度且眼压变化与4 mL无显著差异。
- 阻滞后规范手动按摩可显著降低眼压。
局限性
- 样本量较小,共50只眼完成试验。
- 仅纳入18至79岁拟行眼内手术且排除既往眼或眼眶手术及角膜瘢痕或水肿的眼,外推受限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Peribulbar block (PB) is a widely used anesthesia modality in ophthalmic surgical procedures globally. There are no evidence-based guidelines on PB best practices available. We studied the relationship between block solution volume, the change in intraocular pressure (IOP) and anesthesia effect to guide practice. DESIGN: Prospective, controlled, 1:1 randomized, interventional study carried out at two ambulatory surgical centers. SUBJECTS: Ambulatory male and female patients between age 18 and 79 years of age undergoing planned intraocular surgery with PB as the designated anesthesia modality per surgeon's instruction prior to study enrollment. Eyes with any previous ocular procedure or surgery, or any orbital surgery were excluded. Eyes with corneal scars or cornea edema were also excluded. METHODS: Prior to the scheduled ophthalmic surgery, the enrolled eye was randomized to either 4 mL or 7 mL block volume immediately before PB administration by one of the five anesthesiologists. A regimented 2-minute manual massage was performed by the same research assistant after every block. IOPs were measured with a freshly calibrated tonopen before-block, immediate after-block, and after-manual massage, twice at each time point. Immediately after the completion of the intended surgery, the surgeon was asked to fill the anesthesia satisfaction sheet while staying masked to the block volume. MAIN OUTCOME MEASURES: IOP changes at each step and the surgeons' rating of the quality of anesthesia. RESULTS: There were 50 eyes completed the trial with 25 eyes in each group. There was no statistically significant difference between the two groups in terms of IOP change after the block or after the massage; both groups' IOP decreased significantly after the ocular massage. The 7-mL group achieved a significantly higher surgeon satisfaction score. CONCLUSION: 7-mL PB was shown to be a safe and more effective method for ocular surgical procedures.
引用
- Alam BER, Young SK, Kiyota Y, et al. The Effect of Peribulbar Block Volume on Intraocular Pressure Change: A Randomized Prospective Study. Am J Ophthalmol. 2026. PMID: 42140465. doi:10.1016/j.ajo.2026.05.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。