文献速递眼底病与葡萄膜炎小儿眼科与斜弱视

早产儿视网膜病变检查中非接触手持OCT与接触式眼底照相的应激比较

Preterm Infant Stress During Noncontact Handheld Optical Coherence Tomography and Contact Fundus Photography.
PubMed 文献 · JAMA Ophthalmol · 2026-01-01

这项前瞻性队列研究纳入59名早产儿,比较非接触手持OCT与接触式眼底照相在ROP检查中的应激反应。结果显示OCT组在哭闹评分、面部表情评分和心率变化上均显著低于眼底照相组,且不良事件更少。提示非接触OCT对早产儿应激更小。

要点

  • 非接触手持OCT检查时早产儿哭闹评分和面部表情变化显著低于接触式眼底照相。
  • OCT检查期间及检查后心率变化显著小于眼底照相,差异有统计学意义。
  • 不良事件多数发生在眼底照相期间或之后,OCT相关应激更少。

核心结论

  • 非接触手持OCT对接受ROP检查的早产儿应激更小,相关不良事件更少。

研究设计与样本

  • 前瞻性队列研究,纳入59名早产儿,共397次OCT和眼底照相成像 sessions。
  • 在临床指征的ROP检查期间,按随机顺序使用研究性手持非接触OCT系统和接触式眼底相机进行成像。

主要发现

  • OCT组成像期间哭闹评分较基线变化均值0.12,眼底照相组1.70,均值差-1.59(95%CI -1.75至-1.42)。
  • OCT组成像后哭闹评分变化均值-0.07,眼底照相组0.31,均值差-0.38(95%CI -0.47至-0.28)。
  • OCT组成像期间面部表情评分变化16.8%,眼底照相组75.8%;成像后分别为2.6%和22.5%。
  • OCT组成像期间心率变化均值-5.2 bpm,眼底照相组10.9 bpm,均值差-16.1 bpm(95%CI -19.2至-13.0)。
  • 32次不良事件中26次(81.3%)发生在眼底照相期间或之后,无眼部、意外或严重不良事件。

关键数值与推荐

  • 修改版CRIES新生儿疼痛评分(哭闹评分0-4,面部表情评分0-2)。
  • 收集成像前5分钟、成像期间及成像后1-5分钟的心率、氧饱和度和不良事件。

临床怎么用

  • 在ROP筛查中,非接触手持OCT可能比接触式眼底照相减少早产儿应激和不良事件。
  • 手持OCT在ROP筛查中的作用仍在研究中,临床选择需结合实际情况。

局限性

  • 单中心研究,样本来自单一三级护理中心的新生儿重症监护室。
  • 手持OCT在ROP筛查中的角色尚待进一步研究确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Limiting the stress of retinopathy of prematurity (ROP) assessments may be beneficial for preterm infants. OBJECTIVE: To compare stress in preterm infants from noncontact optical coherence tomography (OCT) vs contact fundus photography during ROP examinations. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective cohort study at an intensive care nursery in a single tertiary care center. Included were infants enrolled in Retinal Microanatomy in ROP (BabySTEPS2) from June 2023 to January 2025. EXPOSURES: During clinically indicated ROP examinations, research imaging with an investigational handheld noncontact OCT system (Duke University) and a contact fundus camera was performed in randomized order in the study eye by expert imagers. Stress data were captured by bedside research nurses. MAIN OUTCOMES AND MEASURES: Modified CRIES (C, crying; R, requires increased oxygen administration; I, increased vital signs; E, expression; S, sleeplessness) neonatal pain score (cry score 0-4, facial expression score 0-2), heart rate, oxygen saturation, and adverse events (AEs) were collected up to 5 minutes before, during, and 1 to 5 minutes after imaging with each device. RESULTS: A total of 59 preterm infants (mean [SD] gestational age, 26.1 [2.0] weeks; 35 male [59.3%]) underwent 397 OCT and fundus photography imaging sessions. Regardless of device order, for OCT compared with fundus photography, there was less change in (1) cry score from baseline to during imaging (mean [SD], 0.12 [0.60] vs 1.70 [1.00]; mean difference, -1.59; 95% CI, -1.75 to -1.42) and after imaging (-0.07 [0.43] vs 0.31 [0.67]; mean difference, -0.38; 95% CI, -0.47 to -0.28; P < .001 for both), (2) facial expression score from baseline to during imaging (16.8% vs 75.8%) and after imaging (2.6% vs 22.5%; P < .001 for both), and (3) heart rate from baseline to during imaging (mean [SD], -5.2 [16.1] bpm vs 10.9 [23.1] bpm; mean difference, -16.1 bpm; 95% CI, -19.2 to -13.0 bpm) and after imaging (-7.2 [17.2] vs 18.8 [21.4] bpm; mean difference, -25.9 bpm; 95% CI, -29.3 to -22.6 bpm; P < .001 for both). Thirty-two AEs (tachycardia, bradycardia, hypoxia, or emesis) occurred in 28 of 399 imaging sessions (7.0%), and 26 of 32 (81.3%) were during or after fundus photography. No ocular, unexpected, or severe AEs occurred. CONCLUSIONS AND RELEVANCE: In this cohort study, although the role of handheld OCT in ROP screening remains under investigation, findings suggest that noncontact handheld OCT was less stressful to preterm infants undergoing ROP examination and resulted in fewer associated AEs compared with contact fundus photography.

来源:JAMA Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Li AS, Sarin N, He J, et al. Preterm Infant Stress During Noncontact Handheld Optical Coherence Tomography and Contact Fundus Photography. JAMA Ophthalmol. 2026. PMID: 42207522. doi:10.1001/jamaophthalmol.2026.1504

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。