文献速递眼底病与葡萄膜炎

硅油取出术中最佳填充剂选择:BSS、空气与C3F8的比较分析

CHOOSING THE OPTIMAL TAMPONADE IN SILICONE OIL REMOVAL: A COMPARATIVE ANALYSIS OF BALANCED SALT SOLUTION, AIR, AND C3F8.
PubMed 文献 · Retina · 2026-01-01

这项回顾性研究纳入60只行23G硅油取出术的眼,分组使用BSS、空气或8%C3F8填充,比较术后视力与眼压。结果显示BSS组术后第1天视力恢复最快,C3F8组在1周及1、3个月视力均较差,各组眼压无显著差异。

要点

  • BSS组术后第1天BCVA显著优于空气组和C3F8组(P<0.001)。
  • C3F8组在术后1周及1、3个月BCVA均低于BSS组和空气组。
  • 各组各时间点眼压均无显著差异。

核心结论

  • 与空气和C3F8相比,BSS在硅油取出术后提供最快的视力恢复。
  • 在常规病例中,BSS是改善短期和长期视力结局并维持正常眼压的最佳选择。

研究设计与样本

  • 回顾性研究,纳入60只行23G硅油取出术的眼,分为BSS组、空气组和8%C3F8组,每组20只眼。
  • 术后第1天、第1周、第1个月和第3个月评估最佳矫正视力(BCVA)和眼压(IOP)。

主要发现

  • 术后第1天,BSS组BCVA显著优于空气组和C3F8组(P<0.001)。
  • 术后1周,空气组BCVA改善至与BSS组相当(P=0.225),而C3F8组BCVA仍差于BSS组(P<0.001)和空气组(P=0.009)。
  • 术后1个月和3个月,BSS组与空气组BCVA无显著差异(1个月P=0.204;3个月P=0.168),但C3F8组BCVA仍较低(所有P<0.05)。
  • 各时间点各组间IOP均无显著差异。

关键数值与推荐

  • BSS组术后第1天BCVA显著优于空气组和C3F8组(P<0.001)。
  • 术后1周空气组与BSS组BCVA相当(P=0.225),C3F8组差于BSS组(P<0.001)和空气组(P=0.009)。
  • 术后1个月BSS组与空气组BCVA比较P=0.204,术后3个月P=0.168。
  • C3F8组在术后1个月和3个月BCVA均低于其他组(所有P<0.05)。
  • 各时间点各组IOP无显著差异。

临床怎么用

  • 在常规硅油取出病例中,可优先考虑BSS作为填充剂以促进术后早期视力恢复。
  • 若需使用C3F8填充,应预期术后视力恢复较慢且长期视力可能较差。
  • 术后各时间点无需因填充剂类型不同而特别担心眼压差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the effects of balanced salt solution (BSS), air, and perfluoropropane (C3F8) as intraocular tamponade agents on visual acuity and intraocular pressure (IOP) after silicone oil (SO) removal surgery. METHODS: This retrospective study included 60 eyes that underwent 23-gauge SO removal and were assigned to the BSS, air, or 8% C3F8 groups (n = 20 per group). Best-corrected visual acuity (BCVA) and IOP were evaluated postoperatively at Day 1, Week 1, Month 1, and Month 3. RESULTS: On postoperative Day 1, the BCVA was significantly better in the BSS group than in the air and C3F8 groups ( P < 0.001). At 1 week, BCVA in the air group improved to a level comparable with that in the BSS group ( P = 0.225), while the BCVA in C3F8 group remained worse than that in both groups ( P < 0.001 vs. BSS; P = 0.009 vs. air). At 1 and 3 months, BCVA did not differ significantly between the BSS and air groups ( P = 0.204 vs. 1 month; P = 0.168 vs. 3 months) but remained lower in the C3F8 group (all P < 0.05). No significant differences in IOP were found between groups at any time point. CONCLUSION: BSS provides the fastest visual recovery after SO removal compared with air and C3F8. It is the optimal choice for improving both short- and long-term visual outcomes while maintaining normal IOP in routine cases.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Jiang X, Huang J, Jiang Z, et al. CHOOSING THE OPTIMAL TAMPONADE IN SILICONE OIL REMOVAL: A COMPARATIVE ANALYSIS OF BALANCED SALT SOLUTION, AIR, AND C3F8. Retina. 2026. PMID: 41949468. doi:10.1097/IAE.0000000000004850

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。