文献速递青光眼眼底病与葡萄膜炎

深度学习在人群青光眼筛查中的应用

Deep learning in population-based screening for glaucoma.
PubMed 文献 · Br J Ophthalmol · 2026-04-15

本研究基于芬兰北部出生队列眼研究,评估深度学习模型G-RISK在45-49岁低患病率(1.1%)人群中从眼底图像筛查青光眼的性能与泛化性。G-RISK在彩色眼底照相筛查青光眼眼时表现最佳,AUC为0.83(95%CI 0.75-0.90),但在95%特异性下敏感度仅0.43(95%CI 0.28-0.59)。筛查指标受队列较年轻和低患病率限制,纳入疑似青光眼时性能下降。

要点

  • G-RISK在彩色眼底照相筛查青光眼眼时AUC最高达0.83(95%CI 0.75-0.90)。
  • 95%特异性下敏感度为0.43(95%CI 0.28-0.59),PR-AUC为0.16(95%CI 0.05-0.28)。
  • 其他成像模态AUC维持在0.75-0.78,筛查确诊青光眼优于联合疑似病例(AUC 0.83 vs 0.67)。

核心结论

  • G-RISK在彩色眼底图像上表现最佳,并在其他成像模态中保持判别能力。
  • 筛查指标受队列较年轻和低青光眼患病率(1.1%)的限制。
  • 纳入青光眼疑似病例时性能下降,可能与疑似病例临床定义的可变性和不确定性有关。

研究设计与样本

  • 基于芬兰北部出生队列眼研究,该研究为随机前瞻性队列,旨在评估中年人群青光眼筛查的疗效和成本效果。
  • 评估G-RISK深度学习模型在45-49岁、青光眼患病率1.1%的人群中从眼底图像筛查青光眼的性能和泛化性。
  • 评估四种筛查场景:青光眼眼、青光眼患者、青光眼及疑似青光眼眼、青光眼及疑似青光眼患者。
  • 使用受试者工作特征曲线下面积(AUC)、精确率-召回率AUC(PR-AUC)和95%特异性下的敏感度评估四种摄影模态的性能。

主要发现

  • G-RISK在彩色眼底照相筛查青光眼眼时性能最高,AUC为0.83(95%CI 0.75-0.90)。
  • 彩色眼底照相筛查青光眼眼时PR-AUC为0.16(95%CI 0.05-0.28),95%特异性下敏感度为0.43(95%CI 0.28-0.59)。
  • 其他模态的判别能力保持一致,AUC为0.75-0.78。
  • 确诊青光眼的性能高于青光眼联合疑似病例(AUC 0.83 vs 0.67)。

关键数值与推荐

  • 筛查青光眼眼使用彩色眼底照相:AUC 0.83(95%CI 0.75-0.90)。
  • 筛查青光眼眼使用彩色眼底照相:PR-AUC 0.16(95%CI 0.05-0.28)。
  • 筛查青光眼眼使用彩色眼底照相:95%特异性下敏感度0.43(95%CI 0.28-0.59)。
  • 其他摄影模态筛查性能:AUC 0.75-0.78。
  • 确诊青光眼与青光眼联合疑似病例比较:AUC 0.83 vs 0.67。

临床怎么用

  • G-RISK可用于彩色眼底照相的青光眼筛查,但在低患病率中年人群中95%特异性下敏感度有限。
  • 筛查确诊青光眼时模型判别能力较好,纳入疑似病例时性能下降,需注意疑似病例定义的不确定性。
  • 其他成像模态也可保持判别能力,可根据实际条件选择摄影模态。

局限性

  • 队列年龄相对年轻(45-49岁)且青光眼患病率低(1.1%),限制了筛查指标。
  • 纳入青光眼疑似病例时性能下降,可能与其临床定义的可变性和不确定性有关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: Deep learning algorithms have shown promise for glaucoma detection using retinal imaging. The Northern Finland Birth Cohort Eye Study is a randomised prospective cohort designed to evaluate the efficacy and cost-effectiveness of glaucoma screening in a middle-aged population. This study assessed the performance and generalisability of G-RISK, a deep learning model for glaucoma screening from fundus images, in individuals aged 45-49 years with low glaucoma prevalence (1.1%). METHODS: Four screening scenarios were evaluated: detection of (1) glaucoma eyes, (2) glaucoma patients, (3) glaucoma and glaucoma suspect eyes and (4) glaucoma and glaucoma suspect patients. Performance across four photographic modalities was assessed using the area under the receiver operating characteristic curve (AUC), the precision-recall AUC (PR-AUC), and sensitivity at 95% specificity. RESULTS: G-RISK achieved its highest performance when screening for glaucoma eyes using colour fundus photographs, with an AUC of 0.83 (95% CI 0.75 to 0.90), PR-AUC of 0.16 (95% CI 0.05 to 0.28) and sensitivity at 95% specificity of 0.43 (95% CI 0.28 to 0.59). Furthermore, discrimination remained consistent across other modalities (AUC 0.75-0.78). Performance was higher for confirmed glaucoma than combined glaucoma and glaucoma suspect cases (AUC 0.83 vs 0.67). CONCLUSIONS: G-RISK achieved the best results on colour fundus images, while maintaining discrimination across other imaging modalities. Screening metrics were constrained by the relatively young age and low glaucoma prevalence of the cohort. The reduced performance observed when including glaucoma suspects may relate to variability and uncertainty in their clinical definition.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Pitkänen J, Hemelings R, Ahokas O, et al. Deep learning in population-based screening for glaucoma. Br J Ophthalmol. 2026. PMID: 41986089. doi:10.1136/bjo-2025-328523

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。