超广角OCT-A评估视网膜非灌注与糖尿病视网膜病变严重程度及周边病灶的相关性
结果显示两种扫描的NPA/ISI均能预测DR严重程度,且21×26-mm扫描的ISI与周边主要病灶(PPL)的存在及范围相关。
要点
- 12×12-mm和21×26-mm扫描的NPA/ISI均与DR严重程度显著相关。
- 21×26-mm扫描的ISI与PPL存在显著相关,且与PPL和DR严重程度的交互作用正相关。
核心结论
- 12×12-mm和21×26-mm扫描的NPA/ISI均可预测DR严重程度,21×26-mm扫描能更好地评估与PPL相关的远周边缺血。
主要发现
- PDR眼NPA和ISI均显著高于NPDR眼(两种扫描均P<.001)。
- 21×26-mm扫描的NPA/ISI显著高于12×12-mm扫描(P<.001)。
- 12×12-mm ISI与DR严重程度相关(OR 1.26,95%CI 1.07-1.48,P=.006),21×26-mm ISI亦相关(OR 1.20,95%CI 1.10-1.29,P<.001)。
- PPL存在仅与21×26-mm扫描的ISI显著相关(B=0.43901,P=.009)。
关键数值与推荐
- PPL定义为在延伸区域中糖尿病病灶超过ETDRS区域50%的视野,若≥1个视野满足则该眼有PPL。
- ROC分析显示两种扫描ISI预测DR严重程度的AUC分别为0.868和0.878(P=.558)。
临床怎么用
- 临床可采用超广角OCT-A的NPA/ISI评估DR缺血严重程度,21×26-mm扫描有助于识别与PPL相关的远周边缺血。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare non perfusion area (NPA) and the ischemic index (ISI) between 2 fields of view using ultra-widefield optical coherence tomography angiography (UWF-OCTA) and evaluate their correlation with diabetic retinopathy (DR) severity and predominantly peripheral lesions (PPL). DESIGN: Cross-sectional, retrospective study. PARTICIPANTS: Sixty-two patients (101 eyes) with DR without prior pan-photocoagulation (PRP) treatment, imaged with 12 × 12-mm and 21 × 26-mm scans on UWF-OCTA. Forty-nine patients (79 eyes) with same-day ultra-widefield color fundus photography (UWF-CFP) were included in the PPL analysis. METHODS: NPA was calculated from UWF-OCTA scans using a semi-automatic algorithm on FIJI. ISI was determined as NPA divided by total scan area. A subset of eyes with same-day UWF CFP were assessed by 2 graders for the presence and extent of fields with PPLs - defined as >50% of diabetic lesions in extended versus Early Treatment of Diabetic Retinopathy Study (ETDRS) fields. Eyes were classified as having PPLs if ≥ 1 field met this criterion. MAIN OUTCOME MEASURES: NPA and ISI from 12 × 12-mm and 21 × 26-mm scans and their association with DR severity. RESULTS: NPA and ISI were significantly greater in PDR versus NPDR for both scans and the NPA/ISI was significantly higher in the 21 × 26-mm scan (P < .001 for all). Both the 12 × 12-mm (OR: 1.26 [95% CI: 1.07-1.48, P = .006]) and the 21 × 26-mm ISI (OR: 1.20 [95% CI: 1.10-1.29, P < .001]) were significantly associated with increasing DR severity. ROC analysis showed similar performance between both scan ISI at predicting DR severity (AUC: 0.868 vs 0.878, P = .558). In the sub-analysis, presence of PPL was only significantly associated with ISI on the 21 × 26-mm scan (B = 0.43901, P = .009). However, the interaction of both presence (B = 0.16, P = .006) and extent (B = 0.2,5 P = .044) of PPLs with increasing DR severity was positively associated with increasing ISI on the 21 × 26-mm scan. CONCLUSIONS: NPA/ISI on both the 12 × 12-mm and 21 × 26-mm scans is predictive of DR severity, highlighting the importance of OCTA detection of ischemia. The wider scan area of the 21 × 26-mm scan can better assess far peripheral ischemia that correlates with PPLs, supporting its potential role in tracking DR progression.
引用
- Gumustop SS, Ding X, Zhang YS, et al. Assessing Retinal Non-Perfusion With Ultra-Widefield OCT-A: Correlations With Diabetic Retinopathy Severity and Peripheral Lesions. Am J Ophthalmol. 2026. PMID: 41967744. doi:10.1016/j.ajo.2026.04.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。