文献速递白内障与屈光手术角膜与眼表疾病

白内障术中散光矫正:环曲面人工晶状体综述概览

Correcting Astigmatism Using Toric Intraocular Lenses During Cataract Surgery.
PubMed 文献 · Am J Ophthalmol · 2026-02-28

PURPOSE: Astigmatism is one of the most common refractive conditions, with a large proportion of patients undergoing cataract surgery presenting with 1.0 D or more. Toric IOLs are the standard of care for astigmatism correction during cataract surgery.…

要点

  • toric IOL是白内障术中矫正散光的标准治疗方式。
  • toric IOL改善显著散光患者的裸眼视力与屈光结果。
  • 诊断、晶状体设计、计算公式及术中工具的进步持续提升精度与患者满意度。

核心结论

  • toric IOL可改善白内障合并显著散光患者的裸眼视力与屈光结果。
  • 诊断、晶状体设计、计算公式及术中工具进步持续提升精度与患者满意度。
  • 尚需进一步研究解决未解问题并支持不同临床环境的最佳实践。

研究设计与样本

  • 叙述性综述概览(overview of reviews),检索MEDLINE、Embase、Cochrane Library(含CENTRAL与Cochrane Database of Systematic Reviews)、KSR Evidence及Trip Database,检索时间自建库至2025年6月2日。

主要发现

  • 综述汇总了散光患病率与影响、toric IOL技术、术前评估、度数计算方法、手术考量及术后结果(如旋转稳定性与手术源性散光)。
  • 同时讨论了报告标准、患者报告结局指标、不良事件及特殊人群中的考量。
  • 文中强调了知识空白与存在争议的领域。

关键数值与推荐

  • 散光是最常见屈光状态之一,很大比例接受白内障手术的患者表现为1.0 D及以上散光。
  • toric IOL是白内障术中散光矫正的标准治疗。

临床怎么用

  • 临床可依据该综述概览了解toric IOL在白内障合并显著散光患者中的临床应用、术前评估与度数计算要点。
  • 关注旋转稳定性与手术源性散光等术后结果,并参考患者报告结局与特殊人群考量。

局限性

  • 本文为叙述性综述概览,未报告纳入综述的具体偏倚评估或定量合并结果。
  • 文中指出存在知识空白与争议领域,尚需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Astigmatism is one of the most common refractive conditions, with a large proportion of patients undergoing cataract surgery presenting with 1.0 D or more. Toric IOLs are the standard of care for astigmatism correction during cataract surgery. This overview of reviews synthesizes current evidence on the use of toric IOLs, focusing on clinical indications, surgical outcomes, and emerging technologies. DESIGN: Narrative review of reviews. METHODS: The following databases were searched from inception to 2 June 2025: MEDLINE, Embase, the Cochrane Library (including CENTRAL and the Cochrane Database of Systematic Reviews), KSR Evidence, and the Trip Database. Keywords included astigmatism, toric intraocular lenses, cataract surgery, intraocular lens implantation, and postoperative outcomes. Included studies were systematic and narrative reviews, meta-analyses, and clinical guidelines related to the use of toric IOLs in cataract surgery. RESULTS: Eighty-five reviews were included. This overview summarizes key topics including the prevalence and impact of astigmatism, toric IOL technology, preoperative assessment, power calculation methods, surgical considerations, and postoperative outcomes such as rotational stability and surgically induced astigmatism. Reporting standards, patient-reported outcome measures, adverse events, and considerations in special populations are also discussed. Knowledge gaps and debated areas are highlighted. CONCLUSIONS: Toric IOLs improve uncorrected visual acuity and refractive outcomes in cataract patients with significant astigmatism. Advances in diagnostics, lens design, calculation formulas, and intraoperative tools continue to enhance accuracy and patient satisfaction. Further research is needed to address unresolved questions and support best practices in diverse clinical settings.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Verstraaten JH, Buzzi M, Masalkhi M, et al. Correcting Astigmatism Using Toric Intraocular Lenses During Cataract Surgery. Am J Ophthalmol. 2026. PMID: 41771334. doi:10.1016/j.ajo.2026.02.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。