文献速递白内障与屈光手术角膜与眼表疾病

消融引导的K测量提高偏心近视LASIK术后IOL度数计算准确性

Ablation-Guided K Measurements Improve the Accuracy of IOL Power Calculation After Clinically Decentered Myopic LASIK.
PubMed 文献 · Am J Ophthalmol · 2026-01-10

本研究在48例既往接受近视LASIK的60只白内障眼上,基于角膜地形图构建消融引导的个性化K测量区域,并与IOLMaster报告的K值比较预测误差。结果显示3.5mm直径环法K3.5ring预测准确性最佳(平均AE=0.64D),且指数P<95.02%或指数D≥1.0975mm时改善更明显,被定义为临床消融偏心。

要点

  • 消融引导的K3.5ring法在近视LASIK术后IOL计算中平均AE为0.64D,准确性最佳。
  • 指数P<95.02%或指数D≥1.0975mm可定义为临床消融偏心,此类眼改善更明显。
  • 研究提供了基于该方法的在线计算工具供临床使用。

核心结论

  • 消融引导的K测量方法可提高临床消融偏心的近视LASIK术后IOL度数计算准确性。

研究设计与样本

  • 回顾性观察性病例系列,纳入48例既往近视LASIK术后白内障患者的60只眼。
  • 在平滑角膜地形图(Pentacam AXL)上勾画消融区域,构建个性化K测量区域。

主要发现

  • 3.5mm直径环法K3.5ring预测准确性最佳,平均AE=0.64D,中位AE=0.47D。
  • 指数P越小(ρ=-0.473,P=.006)或指数D越大(ρ=0.432,P=.014),该方法性能越好。
  • 指数P<95.02%(P=.013)或指数D≥1.0975mm(P=.007)的个性化区域准确性改善更大。

关键数值与推荐

  • 临床消融偏心定义为指数P<95.02%或指数D≥1.0975mm。
  • 指数P为个性化区域在对应圆中所占百分比,指数D为最大内切圆中心到角膜顶点的距离。

临床怎么用

  • 对近视LASIK术后白内障眼,可采用消融引导的K3.5ring法进行IOL度数计算。
  • 关注指数P和指数D以识别临床消融偏心,此类眼可能从该方法中获益更多。
  • 可使用研究提供的在线工具辅助临床计算。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSES: Define clinical ablation decentration and construct personalized areas for K measurements to improve the accuracy of intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK). DESIGN: Retrospective, observational case series. METHODS: Ablation areas were delineated on smoothed corneal topographies (Pentacam AXL). Personalized areas for K measurements were constructed as the overlap between the corneal ablation area and a given apex-centered circle. K values were calculated on these personalized areas using the ring or zone method. Ablation decentration was evaluated by (1) index P: the percentage of the personalized area in the corresponding circle, and (2) index D: the distance from its maximum inscribed circle center to the corneal apex. Their absolute predictive errors (AE) were compared with those of IOLMaster-reported K in 60 cataract eyes from 48 patients with prior LASIK. RESULTS: Ablation-guided K values derived from the 3.5 mm-diameter circle and the ring methods, namely K3.5ring, had the best predictive accuracy (Mean AE = 0.64D, Median AE = 0.47D). This method had better performance with smaller index P (ρ = -0.473, P = .006) and larger index D (ρ = 0.432, P = .014). Personalized areas with index P < 95.02% (P = .013) or index D ≥ 1.0975 mm (P = .007) showed greater accuracy improvements, and were defined as clinical ablation decentration. CONCLUSIONS: This study developed a novel ablation-guided K measurement method for IOL calculation in eyes with clinically decentered myopic ablation. We also provide a ready-to-use tool (https://boluo-baba-ablation-guided-k-measurements.share.connect.posit.cloud) based on this method for clinical convenience.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Zhang M, Lin P, Chen T, et al. Ablation-Guided K Measurements Improve the Accuracy of IOL Power Calculation After Clinically Decentered Myopic LASIK. Am J Ophthalmol. 2026. PMID: 41525815. doi:10.1016/j.ajo.2026.01.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。