文献速递青光眼

原发性房角关闭疾病中虹膜小梁接触指数及相关因素:扫频源前段OCT研究

Exploring iridotrabecular contact index and related factors in primary angle closure disease: a swept-source anterior segment OCT study.
PubMed 文献 · Br J Ophthalmol · 2026-07-22

本研究回顾性分析119眼原发性房角关闭疾病(PACD)患者,使用扫频源前段OCT评估虹膜小梁接触(ITC)指数与前段参数的关系。结果显示相对晶状体拱高与ITC指数显著相关(r=0.451,p<0.001),但决策树分析中加用相对晶状体拱高并未改善角度参数对ITC指数≥50%的判别能力。

要点

  • 相对晶状体拱高与ITC指数呈正相关(r=0.451,p<0.001)。
  • 500微米处房角隐窝面积(ARA 500)检测ITC指数≥50%的AUROC最高(0.983)。
  • 决策树分析中加用相对晶状体拱高未改善角度参数的判别能力。

核心结论

  • PACD患者中相对晶状体拱高与ITC指数显著相关,但晶状体拱高未提升角度参数对ITC指数的诊断准确性。

研究设计与样本

  • 回顾性分析连续PACD患者,所有扫频源前段OCT图像经人工审阅,最终纳入119眼(119例患者)。

主要发现

  • 平均ITC指数为50.2%±30.5%,平均相对晶状体拱高为0.31±0.10。
  • 高拱高(相对晶状体拱高大于三分之一)与更高的ITC指数显著相关(p<0.001),呈正相关(r=0.451,p<0.001)。
  • ARA 500检测ITC指数≥50%的AUROC最高(0.983)。
  • 决策树分析确定500微米处小梁虹膜空间面积和ARA 500为关键因素,但加用相对晶状体拱高未改善区分度。

关键数值与推荐

  • 相对晶状体拱高大于三分之一定义为「高拱高」。
  • ITC指数≥50%为检测目标,ARA 500的AUROC为0.983。

临床怎么用

  • 评估PACD时应综合角度参数,不应仅依赖晶状体测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: This study evaluates the relationship between the iridotrabecular contact (ITC) index and various anterior segment parameters, with a particular focus on lens-related parameters, given their clinical relevance in primary angle closure disease (PACD). METHODS: A retrospective analysis was conducted on consecutive patients with PACD who underwent swept-source anterior segment optical coherence tomography (AS-OCT). All AS-OCT images were manually reviewed. Relative lens vault greater than one-third was defined as 'high vault'." The ability to detect an ITC index ≥50% was assessed using area under the receiver operating characteristic curve (AUROC). Decision tree analysis identified factors influencing the ITC index. RESULTS: A total of 376 patients were initially identified, and after applying exclusion criteria, 119 eyes of 119 PACD patients were included in the final analysis. The mean ITC index was 50.2%±30.5%, with a mean relative lens vault of 0.31±0.10. High vault was significantly associated with higher ITC index (p<0.001), and a positive correlation was observed (r=0.451, p<0.001). The angle recess area at 500 µm (ARA 500) parameter had the highest AUROC (0.983) for detecting ITC index ≥50%. Decision tree analysis identified trabecular iris space area at 500 µm and ARA 500 as key factors, but adding relative lens vault did not improve differentiation. CONCLUSIONS: A significant correlation exists between relative lens vault and the ITC index in PACD. However, lens vault does not enhance the diagnostic accuracy of angle parameters for identifying the ITC index. Comprehensive evaluation of PACD should include parameters beyond lens measurements.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Jeong Y, Park KH, Jeoung JW, et al. Exploring iridotrabecular contact index and related factors in primary angle closure disease: a swept-source anterior segment OCT study. Br J Ophthalmol. 2026. PMID: 41558832. doi:10.1136/bjo-2024-326725

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。