文献速递青光眼

微脉冲激光小梁成形术对色素兔眼压及房水流出影响的机制研究

Effects of Micropulse Laser Trabeculoplasty on Intraocular Pressure and Aqueous Humor Outflow in Pigmented Rabbits.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2026-01-01

本研究在色素兔中观察微脉冲激光小梁成形术(MLT)不同能量(0–1500 mW)对眼压和房水流出通道的影响。结果显示1000 mW和1500 mW能量可显著降低眼压并增加房水流出易度,伴随基质金属蛋白酶(MMPs)一过性上调及房水MMP活性增加,提示MLT通过MMP介导的细胞外基质重塑降低眼压。

要点

  • 1500 mW MLT在术后第3天和第7天显著降低色素兔眼压。
  • 1000和1500 mW MLT均显著增加房水流出易度。
  • MLT通过上调MMPs促进细胞外基质重塑而降低眼压。

核心结论

  • MLT在色素兔中通过促进MMP上调介导的细胞外基质重塑,增加房水流出并降低眼压。

研究设计与样本

  • 色素兔接受0至1500 mW的MLT照射,眼压监测至术后7天。

主要发现

  • 1000 mW组术后第7天眼压显著降低,1500 mW组术后第3天和第7天眼压显著降低。
  • 1000和1500 mW照射眼房水流出易度显著增加。
  • 1500 mW照射眼在房角附近荧光示踪信号强度持续增强。
  • 1500 mW组术后第1天MMP-1、MMP-3和MMP-9基因表达显著上调,第7天MMP-9持续升高。
  • 术后第1天房水MMP活性在1500 mW照射后显著增加。

关键数值与推荐

  • TIMP-1在1500 mW照射后一过性升高,TIMP-2未见变化。

临床怎么用

  • 提示MLT降眼压机制与MMP介导的细胞外基质重塑相关,为临床理解其疗效提供实验依据。

局限性

  • 研究为色素兔动物实验,结果外推至人类需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Micropulse laser trabeculoplasty (MLT) is an established treatment for primary open-angle glaucoma; however, the mechanisms underlying its IOP-lowering effect remain incompletely understood, particularly in vivo. We investigated the mechanisms of MLT in vivo, with a focus on the trabecular meshwork outflow pathway. METHODS: Pigmented rabbits received MLT at 0 to 1500 mW, and IOP was monitored for up to 7 days posttreatment. Outflow facility was assessed, and aqueous outflow was visualized using fluorescent dextran tracer imaging. Angle tissues were collected at 1 and 7 days for quantitative RT-PCR analysis of matrix metalloproteinases (MMPs), tissue inhibitors of metalloproteinases (TIMPs), and extracellular matrix (ECM) components. Aqueous humor samples were analyzed for MMP enzymatic activity. RESULTS: At 1000 mW, IOP was significantly reduced on day 7, and at 1500 mW, it was significantly reduced on days 3 and 7. Aqueous outflow facility was significantly increased in the 1000- and 1500-mW irradiated eyes. Tracer imaging consistently demonstrated stronger signal intensity near the angle in the 1500-mW irradiated eyes. Gene expression analysis exhibited significant upregulation of MMP-1, -3, and -9 at day 1, with sustained elevation of MMP-9 at day 7 after the 1500-mW treatment. TIMP-1 was transiently elevated, whereas TIMP-2 remained unchanged. Aqueous humor MMP activity was significantly increased at 1 day after 1500-mW irradiation. CONCLUSIONS: MLT induced transient MMP activation, enhanced aqueous outflow, and reduced IOP. These findings imply that MLT lowers IOP in pigmented rabbits by promoting ECM remodeling through MMP upregulation.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Shimizu S, Nemoto H, Ohata S, et al. Effects of Micropulse Laser Trabeculoplasty on Intraocular Pressure and Aqueous Humor Outflow in Pigmented Rabbits. Invest Ophthalmol Vis Sci. 2026. PMID: 41528104. doi:10.1167/iovs.67.1.29

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。