通过预测修正优化高屈光度人工晶状体度数计算:多公式分析

Refining Intraocular Lens Power Calculations With Prediction Modifications: A Multiformula Analysis in High-Power Lenses.
PubMed 文献 · Am J Ophthalmol · 2025-11-16

本回顾性研究纳入645眼(497例)植入TECNIS ZCB00或ICB00人工晶状体者,按中央屈光度(17.5-23.5 D)与高屈光度(>23.5 D)分组,优化公式常数并评估12种公式在应用预测修正前后的屈光预测误差。高屈光度组应用预测修正后,除PEARL-DGS的MAE(P=0.050)外,所有公式的MRE、MAE和RMSAE均显著降低(均P<0.05)。

要点

  • 预测修正可有效校正高屈光度人工晶状体的近视漂移。
  • 高屈光度组眼轴更短、前房更浅、晶状体更厚(均P<0.001)。
  • 中央屈光度组优化后所有公式MRE达-0.01至0.01 D。

核心结论

  • 预测修正是针对公式预测等效球镜的简单屈光度特异性调整,可有效提高高屈光度人工晶状体的屈光预测准确性并减少残留系统误差。

研究设计与样本

  • 回顾性准确性与有效性分析,纳入645眼(497例)植入TECNIS ZCB00或ICB00人工晶状体者,按中央屈光度(17.5-23.5 D)和高屈光度(>23.5 D)分组,用中央屈光度组优化公式常数并应用于两组。

主要发现

  • 高屈光度组眼轴显著更短、前房深度显著更浅、晶状体厚度显著更大(均P<0.001)。
  • 中央屈光度(17.5-23.5 D)组优化后,包括Barrett Universal II、Cooke K6、EVO 2.0、Haigis、Hoffer QST、Holladay 1、Holladay 2 with nonlinear regression(H2 NLR)、Kane、Olsen、PEARL-DGS、SRK/T和T2在内的所有公式MRE为-0.01至0.01 D。
  • 高屈光度(>23.5 D)组应用预测修正后,所有公式的MRE、MAE和RMSAE均显著降低(均P<0.05),但PEARL-DGS的MAE除外(P=0.050)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the effectiveness of prediction modifications (PMOD) in improving refractive accuracy of modern intraocular lens (IOL) formulas in high-power TECNIS IOLs. DESIGN: Retrospective accuracy and validity analysis. SUBJECTS: Eyes with high-power and central power diopter IOL undergoing cataract surgery. METHODS: This retrospective study included 645 eyes (497 patients) implanted with TECNIS ZCB00 or ICB00 IOLs. Eyes were stratified into central power (17.5-23.5 D) and high-power (>23.5 D) groups. Formula constants were optimized using the central power group and applied to both groups. PMOD, based on prior large-scale regression data, were applied to the high-power group. Twelve IOL power formulas were evaluated before and after PMOD application. Prediction errors were analyzed using mean refractive error (MRE), mean absolute error (MAE), and root mean square absolute error (RMSAE) with the Wilcox-Holladay-Wang-Koch method. MAIN OUTCOME MEASURES: MRE, MAE, and RMSAE. RESULTS: In the high-power group, eyes exhibited significantly shorter axial length, shallower anterior chamber depth, and greater lens thickness (all P < .001). All formulas, including Barrett Universal II, Cooke K6, EVO 2.0, Haigis, Hoffer QST, Holladay 1, Holladay 2 with nonlinear regression (H2 NLR), Kane, Olsen, PEARL-DGS, SRK/T, and T2, achieved -0.01 to 0.01 D MRE after optimization in the central power (17.5-23.5 D) group. In the high-power (>23.5 D) group, PMOD effectively corrected the myopic shift, significantly reducing MRE, MAE, and RMSAE across all formulas (all P < .05), except for MAE in PEARL-DGS (P = .050). CONCLUSIONS: PMOD is a simple diopter-specific adjustment applied to the formula-predicted spherical equivalent. It effectively improved refractive prediction accuracy and reduced residual systematic errors that persisted in high-power IOLs across formulas, even after applying constants optimized in the central power group.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。