使用超高分辨率OCT对剥脱综合征中剥脱物质进行三维形态学分析
本研究对17只剥脱综合征(XFS)眼使用超高分辨率光学相干断层扫描(UHR-OCT)径向扫描成像,并结合晶状体照相,微调Segment Anything Model自动识别晶状体前囊及表面,对剥脱物质进行分割、分类和体积定量。结果显示UHR-OCT可清晰显示剥脱物质异质性外观,剥脱物质平均体积为10.9 ± 4.0 × 10^7 µm³,周边带略多于中央盘。
要点
- UHR-OCT在XFS眼前表面可分辨出比晶状体照相更多的微观病理特征。
- 剥脱物质被分为沉积、剥离和脱离三类,平均体积分别为9.0 ± 4.3、1.6 ± 1.1和0.3 ± 0.6 × 10^7 µm³。
- 周边带剥脱物质体积略多于中央盘(5.5 ± 3.7 × 10^7 µm³ vs. 5.4 ± 2.8 × 10^7 µm³)。
核心结论
- UHR-OCT清晰显示XFS中剥脱物质的异质性外观,可进行定量分析,并可能用于监测其随时间沉积。
研究设计与样本
- 研究共纳入17只XFS眼,使用晶状体照相和径向扫描UHR-OCT获取容积图像,并微调Segment Anything Model自动识别晶状体前囊和表面。
主要发现
- 与晶状体照相相比,UHR-OCT在XFS眼晶状体前表面分辨出更多微观病理特征,包括增厚的囊膜层伴细小颗粒状物质以及剥脱物质剥离或脱离晶状体表面。
- En face OCT图像显示晶状体囊中央和周边区域散在的高反射沉积物以及弥漫增厚的囊膜层。
- 剥脱物质平均体积为10.9 ± 4.0 × 10^7 µm³,其中沉积为9.0 ± 4.3 × 10^7 µm³、剥离为1.6 ± 1.1 × 10^7 µm³、脱离为0.3 ± 0.6 × 10^7 µm³。
- 周边带剥脱物质体积略多于中央盘(5.5 ± 3.7 × 10^7 µm³ vs. 5.4 ± 2.8 × 10^7 µm³)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Exfoliation syndrome (XFS), characterized by the accumulation of fibrillar extracellular material in the anterior segment, is a leading cause of secondary glaucoma worldwide. This study aimed to characterize the three-dimensional morphology of exfoliative material on the anterior lens surface in XFS eyes using ultrahigh-resolution optical coherence tomography (UHR-OCT). METHODS: We imaged 17 eyes with lens photography and acquired volumetric UHR-OCT using radial scanning. We fine-tuned the Segment Anything Model to automatically identify the anterior lens capsule and surface. The exfoliative material was segmented and categorized as deposited (thickened epithelium layer), peeling-off, or detached, as well as central versus peripheral. Volumetric quantification of each category was also performed to assess the distribution of exfoliative material. RESULTS: Compared to lens photography, UHR-OCT resolved greater microscopic pathological features on the anterior lens surface in XFS, including a thickened capsular layer with small/grainy material and exfoliative material peeling-off or detached from the lens surface. En face OCT images showed the scattered hyperreflective deposits across central and peripheral regions of the lens capsule, as well as diffused, thickened capsular layers. From volumetric analysis, the average volume of exfoliative material was 10.9 ± 4.0 × 107 µm3, consisting of deposited (9.0 ± 4.3 × 107 µm3), peeling-off (1.6 ± 1.1 × 107 µm3), and detached (0.3 ± 0.6 × 107 µm3). The peripheral band had slightly more exfoliative material than the central disc (5.5 ± 3.7 × 107 µm3 vs. 5.4 ± 2.8 × 107 µm3). CONCLUSIONS: UHR-OCT clearly visualizes the heterogeneous appearance of exfoliative material in XFS, enables quantitative analysis, and can potentially be used to monitor its deposition over time.