三维整合方法用于青光眼结构与功能监测
该回顾性纵向研究纳入996例青光眼患者的1742只眼,随访≥4年,构建整合结构与功能随时间变化的三维轨迹模型。结构数据转换为结构综合评分(SMS),以视野指数(VFI)为功能参数,按基线平均偏差(MD)分层。SMS方法预测误差为8.9%,单设备方法为34.1%。
要点
- SMS斜率从视野前期-0.1±0.8%/年至重度-0.8±0.7%/年,VFI斜率从-0.2±0.5%/年至-0.9±1.4%/年(p<0.001)。
- 进展分类:结构与功能均进展6%,仅结构进展13%,仅功能进展11%,稳定70%。
- 仅功能进展在中重度青光眼更常见,仅结构进展在早期阶段占优;SMS预测误差8.9% vs 单设备34.1%。
核心结论
- 三维轨迹模型可可视化不同进展模式,早期结构改变先于功能下降,晚期以仅功能进展为主,该整合模型增强疾病动态的可视化与量化,支持个性化青光眼管理。
研究设计与样本
- 回顾性纵向研究,纳入996例青光眼患者的1742只眼,随访≥4年。
主要发现
- SMS斜率从视野前期-0.1±0.8%/年至重度-0.8±0.7%/年,VFI斜率从-0.2±0.5%/年至-0.9±1.4%/年(p<0.001)。
- 结构与功能斜率在早期阶段相关性更强。
- 进展分类:结构与功能均进展6%,仅结构进展13%,仅功能进展11%,稳定70%。
- 仅功能进展在中度和重度青光眼更常见,仅结构进展在早期阶段占优。
- SMS方法预测误差为8.9%,单设备方法为34.1%。
关键数值与推荐
- 按基线平均偏差(MD)分层:视野前期(MD≥0 dB)、轻度(-6<MD<0 dB)、中度(-12≤MD≤-6 dB)、重度(MD<-12 dB)。
- 进展定义为SMS或VFI的斜率<-1%/年。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To introduce a three-dimensional (3D) trajectory model that integrates structural and functional changes over time to improve assessment and prediction of glaucoma progression. METHODS: This retrospective longitudinal study included 1742 eyes from 996 glaucoma patients with ≥4 years of follow-up. Structural data from various devices were converted into a Structural Metascore (SMS), and the Visual Field Index (VFI) was used as the functional parameter. Robust linear regression was applied to each eye's SMS and VFI over time. Eyes were categorised by baseline mean deviation (MD) into preperimetric (MD ≥0 dB), mild (-6 < MD < 0 dB), moderate (-12 ≤ MD ≤ -6 dB) or severe (MD <-12 dB). Progression was defined as a slope <-1% per year for SMS or VFI. RESULTS: Mean SMS slopes ranged from -0.1±0.8%/year (preperimetric) to -0.8±0.7%/year (severe) and VFI slopes ranged from -0.2±0.5%/year to -0.9±1.4%/year (p<0.001). Structural and functional slopes were more correlated in earlier stages. Progression classifications were: both structural and functional (6%), structural-only (13%), functional-only (11%) and stable (70%). Functional-only progression was more common in moderate and severe glaucoma, while structural-only progression predominated in earlier stages. The SMS approach achieved 8.9% prediction error compared with 34.1% for single-device methods. CONCLUSION: The 3D trajectory model visualises distinct progression patterns, with structural changes preceding functional decline in earlier stages and functional-only progression dominating in advanced stages. This integrated model enhances visualisation and quantification of disease dynamics, supporting personalised glaucoma management.
引用
- Lee K, Morales E, de Gainza A, et al. 3D integrated approach to structural and functional monitoring in glaucoma. Br J Ophthalmol. 2026. PMID: 41192944. doi:10.1136/bjo-2025-327847
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。