文献速递白内障与屈光手术

晶状体赤道面评估:一种预测术后人工晶状体位置的新型SS-OCT生物测量参数

Evaluation of Crystalline Lens Equatorial Plane: A Novel SS-OCT Biometry Parameter For Predicting Postoperative Intraocular Lens Position.
PubMed 文献 · Am J Ophthalmol · 2025-10-22

这项前瞻性连续对照研究纳入185只眼,利用SS-OCT生物测量和自研软件估算晶状体赤道面(EQ),评估其预测白内障术后人工晶状体位置的能力。EQ与术后IOL位置强相关(r=0.82,P<.0001),含EQ相关参数的模型R²达0.709、RMSE为0.133,优于传统参数模型(R²=0.644,RMSE=0.148;P<.0001)。作者认为这些发现支持将晶状体赤道面参数整合到下一代IOL度数计算公式中进行测试。

要点

  • EQ与术后IOL位置强相关(r=0.82,P<.0001)。
  • 含EQ相关参数的最优模型R²=0.709、RMSE=0.133,优于传统模型(R²=0.644、RMSE=0.148;P<.0001)。
  • 眼轴长度>24.5mm的眼中,纳入EQ相关指标使预测显著改善(R²=0.717,RMSE=0.107;P=.045)。

核心结论

  • 包含晶状体赤道面参数(LEP)的模型预测准确性优于基于传统参数的模型。
  • 这些发现支持将LEP整合到下一代IOL度数计算公式中进行测试。

研究设计与样本

  • 前瞻性、连续、比较准确性及有效性分析。
  • 共纳入185例患者185只眼,均行超声乳化白内障吸除联合囊袋内IOL植入;其中男性76例(41.1%)、女性109例(58.9%),平均年龄71.6±8.2岁。
  • 术前使用Anterion平台行SS-OCT生物测量,EQ定义为角膜上皮至连接晶状体前后面曲率交点连线的距离,采用半自动Python 3软件检测晶状体表面并计算EQ参数。
  • 术后行SS-OCT成像测量IOL位置,建立线性回归模型评估EQ及传统生物测量变量的预测性能。

主要发现

  • EQ与术后IOL位置呈强相关(r=0.82,P<.0001)。
  • 包含ACD、LT和WTW的传统模型R²为0.644,RMSE为0.148。
  • 仅用EQ的简单回归使R²提高至0.670。
  • 包含EQ相关参数(晶状体自EQ平面及自角对角线的上升量)的最优模型R²为0.709,RMSE为0.133(与传统模型相比P<.0001)。
  • 眼轴长度>24.5mm的眼中,纳入EQ相关指标使预测显著改善(R²=0.717,RMSE=0.107;P=.045)。

关键数值与推荐

  • EQ与术后IOL位置相关系数r=0.82(P<.0001)。
  • 传统模型(ACD、LT、WTW)R²=0.644,RMSE=0.148。
  • 仅EQ模型R²=0.670。
  • 最优模型(EQ相关参数)R²=0.709,RMSE=0.133,与传统模型比较P<.0001。
  • 眼轴长度>24.5mm亚组:R²=0.717,RMSE=0.107,P=.045。

临床怎么用

  • 原文结论认为包含LEP的模型准确性优于传统参数模型,并支持将LEP整合到下一代IOL度数计算公式中进行测试。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate whether the equatorial lens plane (EQ), estimated using swept-source optical coherence tomography (SS-OCT) biometry and custom-developed software, improves the prediction of postoperative intraocular lens (IOL) position compared to conventional biometric parameters. DESIGN: Prospective, consecutive, comparative accuracy and validity analysis. SUBJECTS, PARTICIPANTS, AND/OR CONTROLS: A total of 185 eyes from 185 patients undergoing cataract surgery with phacoemulsification and in-the-bag IOL implantation were included. The cohort included 76 male (41.1%) and 109 female (58.9%) patients, with a mean age of 71.6 ± 8.2 years. METHODS, INTERVENTION, OR TESTING: Preoperative SS-OCT biometry was obtained using the Anterion platform. The EQ was defined as the distance from the corneal epithelium to the line connecting the intersection points of the anterior and posterior lens curvatures. A semi-automatic Python 3 software was used to detect lens surfaces and calculate the EQ parameter. Postoperative SS-OCT imaging was performed to measure IOL position. Linear regression models were built to evaluate the predictive performance of EQ and conventional biometric variables. MAIN OUTCOME MEASURES: Postoperative IOL position prediction accuracy, assessed using adjusted R², mean absolute error (MAE), and root mean squared error (RMSE). RESULTS: The EQ showed a strong correlation with postoperative IOL position (r = 0.82, P < .0001). A conventional model including ACD, LT, and WTW achieved an R² of 0.644 and RMSE of 0.148. A simple regression using EQ alone improved R² to 0.670. The best-performing model included EQ-related parameters-lens rise from the EQ plane and from angle-to-angle-achieving an R² of 0.709 and RMSE of 0.133 (P < .0001 vs. conventional model). In eyes with axial length > 24.5 mm, the inclusion of EQ-related metrics improved prediction significantly (R² = 0.717, RMSE = 0.107; P = .045). CONCLUSIONS: Models incorporating LEP demonstrated superior accuracy compared to those based on conventional parameters. These findings support testing the integration of LEP into the next-generation IOL power calculation formulas.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Romero D, Cooke D, Alió JL, et al. Evaluation of Crystalline Lens Equatorial Plane: A Novel SS-OCT Biometry Parameter For Predicting Postoperative Intraocular Lens Position. Am J Ophthalmol. 2025. PMID: 41135931. doi:10.1016/j.ajo.2025.10.015