高度近视所致视神经乳头变形与青光眼进展:三年随访研究
该前瞻性队列研究纳入242眼(高度近视青光眼97眼,轴长>26.5 mm;开角型青光眼145眼,轴长≤26.5 mm),用谱域OCT量化视神经乳头参数并随访3年视野和视盘旁视网膜神经纤维层厚度。高度近视青光眼眼BMO面积、ASCO面积、ASCO-BMO偏移更大,NCMCA更小,颞侧视野进展和pRNFL变薄更快;NCMCA是全视野进展的独立预测因子。
要点
- 高度近视青光眼眼BMO面积3.0 vs 开角型青光眼2.3 mm²(P<0.001),ASCO面积2.6 vs 2.4 mm²(P<0.001)。
- 高度近视青光眼眼ASCO-BMO偏移376.1 vs 161.5 µm(P<0.001),NCMCA 1.0 vs 1.3 mm²(P<0.001)。
- 高度近视青光眼眼颞侧视野进展0.173 vs 0.060 dB/y(P=0.023),pRNFL变薄0.96 vs 0.64 µm/y(P=0.014)。
核心结论
- 高度近视所致视神经乳头变形,尤其是鼻侧倾斜和NCMCA减小,加速颞侧青光眼性损害。
- NCMCA是进展风险的关键生物标志物,支持对高度近视青光眼进行个体化管理。
研究设计与样本
- 前瞻性队列研究,纳入242眼:高度近视青光眼97眼(轴长>26.5 mm),开角型青光眼145眼(轴长≤26.5 mm)。
- 用谱域OCT量化Bruch膜开口(BMO)、前巩膜管开口(ASCO)面积、神经管最小横截面积(NCMCA)和ASCO-BMO偏移。
- 随访3年,监测视野缺损和视盘旁视网膜神经纤维层(pRNFL)厚度,采用广义线性混合模型和多因素回归分析。
主要发现
- 与开角型青光眼相比,高度近视青光眼眼BMO面积更大(3.0 vs 2.3 mm²,P<0.001),ASCO面积更大(2.6 vs 2.4 mm²,P<0.001)。
- 高度近视青光眼眼ASCO-BMO偏移更大(376.1 vs 161.5 µm,P<0.001),NCMCA更小(1.0 vs 1.3 mm²,P<0.001)。
- 高度近视青光眼眼颞侧视野进展更快(0.173 vs 0.060 dB/y,P=0.023),pRNFL变薄更快(0.96 vs 0.64 µm/y,P=0.014)。
- 多因素分析显示NCMCA是全视野进展的独立预测因子(β=-0.03,P=0.021)。
关键数值与推荐
- 高度近视青光眼定义:青光眼且轴长>26.5 mm;开角型青光眼定义:开角型青光眼且轴长≤26.5 mm。
- NCMCA与全视野进展独立相关(β=-0.03,P=0.021)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the biomechanical effects of high myopia (HM)-related optic nerve head (ONH) structural changes on glaucoma progression and identify key predictive parameters. METHODS: This prospective cohort study enrolled 242 eyes: 97 highly myopic glaucoma (HMG), axial length > 26.5 mm; 145 open-angle glaucoma (OAG), axial length ≤ 26.5 mm. ONH parameters, including Bruch's membrane opening (BMO), anterior scleral canal opening (ASCO) areas, neural canal minimum cross-sectional area (NCMCA), and ASCO-BMO offset, were quantified via spectral-domain OCT. Visual field (VF) defects and parapapillary retinal nerve fiber layer (pRNFL) thickness were monitored over 3 years. Generalized linear mixed models and multivariate regression were used for analysis. RESULTS: Compared with OAG, HMG eyes exhibited larger BMO areas (3.0 vs. 2.3 mm2, P < 0.001) and ASCO areas (2.6 vs. 2.4 mm2, P < 0.001), greater ASCO-BMO offset (376.1 vs. 161.5 µm, P < 0.001), smaller NCMCA (1.0 vs. 1.3 mm2, P < 0.001), and faster temporal VF progression (0.173 vs. 0.060 dB/y, P = 0.023) and pRNFL thinning (0.96 vs. 0.64 µm/y, P = 0.014). Multivariate analysis identified NCMCA as an independent predictor of global progression (β = -0.03, P = 0.021). CONCLUSIONS: HM-induced ONH deformation, particularly nasal tilting and reduced NCMCA, accelerates temporal glaucomatous damage. NCMCA serves as a critical biomarker for progression risk, supporting individualized management in glaucoma with HM.
引用
- Dai J, Wang X, Han Y, et al. High Myopia-Induced Optic Nerve Head Deformation and Glaucoma Progression: A Three-Year Follow-Up Study. Invest Ophthalmol Vis Sci. 2025. PMID: 41104958. doi:10.1167/iovs.66.13.30
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。