文献速递眼底病与葡萄膜炎

六种影像模态检测新生血管性年龄相关性黄斑变性黄斑萎缩的诊断性能比较

Comparative diagnostic performance of six imaging modalities for detecting macular atrophy in neovascular age-related macular degeneration.
PubMed 文献 · Br J Ophthalmol · 2026-03-20

本回顾性队列研究纳入113只接受抗血管内皮生长因子治疗至少1年的新生血管性年龄相关性黄斑变性眼,在同一访视时行六种影像模态检查,以资深视网膜专家基于多模态标准判定的黄斑萎缩为参考标准。结构OCT诊断准确度最高,敏感度92.4%、特异度96.7%;其他模态敏感度64.1-77.4%、特异度75.0-88.3%;彩色眼底照相读者间一致性最低(κ=0.18)。

要点

  • 结构OCT检测黄斑萎缩的敏感度92.4%、特异度96.7%,为六种模态中最高。
  • 蓝自身荧光读者间一致性中等(κ=0.46),其余模态较低,彩色眼底照相最低(κ=0.18)。
  • 其他模态敏感度64.1-77.4%、特异度75.0-88.3%,可在需要时补充OCT,但彩色眼底照相单独应用有限。

核心结论

  • 结构OCT对新生血管性年龄相关性黄斑变性黄斑萎缩的检测具有最高准确度和可靠性,支持其在临床实践和研究中的应用。
  • 其他模态可在需要时补充OCT,但彩色眼底照相单独应用有限。

研究设计与样本

  • 本回顾性队列研究纳入113只接受抗血管内皮生长因子治疗至少1年的新生血管性年龄相关性黄斑变性眼。
  • 所有眼在同一访视时接受彩色眼底照相、多色成像、蓝自身荧光、绿自身荧光、近红外反射和结构OCT六种影像模态检查。
  • 黄斑萎缩由资深视网膜专家使用多模态标准判定,并作为诊断参考(即金标准)。
  • 两名设盲阅片者使用各模态特异性定义独立评估图像,分歧通过共识解决。

主要发现

  • 基于多模态影像,46.9%的眼存在黄斑萎缩。
  • 结构OCT在43.4%的病例中检测到黄斑萎缩,其次为绿自身荧光(36.3%)、蓝自身荧光和近红外反射(各35.4%)、多色成像(33.6%)和彩色眼底照相(30.1%)。
  • 结构OCT诊断准确度最高,敏感度92.4%、特异度96.7%。
  • 其他模态显示中等敏感度(64.1-77.4%)和特异度(75.0-88.3%)。
  • 蓝自身荧光读者间一致性中等(κ=0.46),其余模态较低,彩色眼底照相最低(κ=0.18)。

关键数值与推荐

  • 黄斑萎缩以资深视网膜专家基于多模态标准判定为诊断参考(金标准)。
  • 结构OCT:敏感度92.4%,特异度96.7%。
  • 其他模态:敏感度64.1-77.4%,特异度75.0-88.3%。
  • 读者间一致性:蓝自身荧光κ=0.46,其余模态较低,彩色眼底照相κ=0.18。

临床怎么用

  • 作者认为结构OCT对新生血管性年龄相关性黄斑变性黄斑萎缩检测具有最高准确度和可靠性,支持其在临床实践和研究中的应用。
  • 作者认为其他模态可在需要时补充OCT,但彩色眼底照相单独应用有限。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the diagnostic accuracy of six imaging modalities-colour fundus photography (CFP), multicolour imaging (MC), blue autofluorescence (BAF), green autofluorescence (GAF), near-infrared reflectance (NIR) and structural optical coherence tomography (OCT)-for detecting macular atrophy (MA) in patients with previously treated neovascular age-related macular degeneration (AMD). METHODS: This retrospective cohort study included 113 eyes from patients treated with anti-vascular endothelial growth factor for at least 1 year. All eyes underwent six imaging modalities during the same visit. MA was identified by a senior retinal specialist using multimodal criteria and served as the diagnostic reference (ie, gold standard). Sensitivity and specificity of each imaging modality were calculated relative to this reference. Two masked graders independently assessed images using modality-specific definitions of MA. Discrepancies were resolved by consensus. Sensitivity, specificity, positive predictive value, negative predictive value and inter-reader agreement were calculated for each modality. RESULTS: MA was present in 46.9% of eyes based on multimodal imaging. Structural OCT detected MA in 43.4% of cases, followed by GAF (36.3%), BAF and NIR (35.4% each), MC (33.6%) and CFP (30.1%). Structural OCT demonstrated the highest diagnostic accuracy, with 92.4% sensitivity and 96.7% specificity. Other modalities showed moderate sensitivity (64.1-77.4%) and specificity (75.0-88.3%). Inter-reader agreement was moderate for BAF (κ=0.46) and lower for the remaining modalities, lowest for CFP (κ=0.18). CONCLUSIONS: Structural OCT offers the highest accuracy and reliability for detecting MA in neovascular AMD, supporting its use in both clinical practice and research. Other modalities may supplement OCT when needed, but CFP alone is limited.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Olivieri C, Neri G, Ricardi F, et al. Comparative diagnostic performance of six imaging modalities for detecting macular atrophy in neovascular age-related macular degeneration. Br J Ophthalmol. 2026. PMID: 41047158. doi:10.1136/bjo-2025-328225

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。