文献速递角膜与眼表疾病白内障与屈光手术

穿透性角膜移植或深板层角膜移植术后角膜多焦性与人工晶状体度数计算误差相关

Corneal multifocality after penetrating keratoplasty or deep anterior lamellar keratoplasty is associated with intraocular lens power calculation error.
PubMed 文献 · Br J Ophthalmol · 2026-01-22

这项回顾性研究纳入74只穿透性角膜移植(PK)或深板层角膜移植(DALK)术后行白内障手术的眼,比较SRK/T、Haigis、Barrett Universal II(BUII)与Kane公式的预测误差;在27只具有术后眼前节OCT数据的眼中,基于术后屈光、人工晶状体位置、人工晶状体度数与眼轴用Zemax计算主观角膜曲率值(SK),并与OCT所得角膜曲率值(K值)比较。结果显示各公式平均绝对预测误差为1.50±1.60 D(SRK/T)、1.96±1.80 D(Haigis)、1.84±1.71 D(BUII)、1.83±1.86 D(Kane);作者结论认为PK或DALK术后多焦角膜的SK值可能与OCT所得K值明显不同,使用标准K值的传统人工晶状体公式可能导致白内障术后屈光意外。

要点

  • PK或DALK术后行白内障手术眼,SRK/T平均绝对预测误差为1.50±1.60 D。
  • Haigis、BUII、Kane平均绝对预测误差分别为1.96±1.80 D、1.84±1.71 D、1.83±1.86 D。
  • SK与真实K值(TK)显著相关(r=0.86,p<0.001),SK与TK的差值与SRK/T预测误差显著相关(r=0.53,p=0.001)。

核心结论

  • PK或DALK术后的多焦角膜,其SK值可能与AS-OCT所得K值明显不同,使用标准K值的传统人工晶状体公式可能导致白内障术后屈光意外。

研究设计与样本

  • 回顾性研究,纳入74只行PK或DALK后接受白内障手术的眼,比较SRK/T、Haigis、BUII与Kane公式的预测误差;其中27只眼有术后AS-OCT数据,用Zemax基于术后屈光、人工晶状体位置、人工晶状体度数与眼轴计算SK,并与AS-OCT所得K值比较。

主要发现

  • 平均绝对预测误差为SRK/T 1.50±1.60 D、Haigis 1.96±1.80 D、BUII 1.84±1.71 D、Kane 1.83±1.86 D。
  • SK与TK显著相关(r=0.86,p<0.001)。
  • SK与TK的差值与SRK/T的预测误差显著相关(r=0.53,p=0.001)。
  • SRK/T的预测误差被建模为术前与术后K值变化以及TK与SK之差的函数,纳入这些参数后预测误差显著改善。

关键数值与推荐

  • SRK/T平均绝对预测误差1.50±1.60 D,Haigis 1.96±1.80 D,BUII 1.84±1.71 D,Kane 1.83±1.86 D。
  • SK与TK相关r=0.86(p<0.001);SK与TK之差与SRK/T预测误差相关r=0.53(p=0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: The purpose of this study is to investigate the accuracy of intraocular lens (IOL) power calculation after penetrating keratoplasty (PK) or deep anterior lamellar keratoplasty (DALK) and to identify the causes of predictive errors (PEs) in relation to the subjective keratometric (K) value (SK) in eyes with corneal multifocality. METHODS: This retrospective study included 74 eyes that underwent cataract surgery after PK or DALK. PEs were compared between SRK/T, Haigis, Barrett Universal II (BUII) and Kane formulas. In 27 eyes with postoperative anterior segment optical coherence tomography (AS-OCT) data, SKs were calculated based on postoperative refraction, IOL position, IOL power and axial length using Zemax. This was compared with K values obtained using AS-OCT. RESULTS: Mean absolute PE was 1.50±1.60 dioptre in SRK/T, 1.96±1.80 in Haigis, 1.84±1.71 in BUII and 1.83±1.86 in Kane. SK was significantly correlated with true K (TK) (r=0.86, p<0.001). The difference between SK and TK showed a significant correlation with PE in SRK/T (r=0.53, p=0.001). The PE in SRK/T was modelled as a function of the change in preoperative and postoperative K values as well as the difference between TK and SK, with significant improvement in the PE after factoring in these parameters. CONCLUSIONS: Multifocal corneas, such as those after PK or DALK, may have SK values that differ significantly from K values obtained from AS-OCT. Therefore, traditional IOL formulas that use standard K values may lead to a refractive surprise after cataract surgery.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Shiraishi Y, Chang EK, Yagi-Yaguchi Y, et al. Corneal multifocality after penetrating keratoplasty or deep anterior lamellar keratoplasty is associated with intraocular lens power calculation error. Br J Ophthalmol. 2026. PMID: 40850739. doi:10.1136/bjo-2025-327868

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。