文献速递白内障与屈光手术眼底病与葡萄膜炎

新一代人工晶状体屈光度计算公式在高度近视眼中的准确性:日本多中心研究

Accuracy of New-Generation Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes: A Multicenter Study in Japan.
PubMed 文献 · Am J Ophthalmol · 2025-08-10

该日本4中心回顾性病例系列纳入326眼轴长≥26.0 mm的高度近视眼,比较13种人工晶状体屈光度计算公式的屈光预测准确性。Hoffer QST、Holladay 1 WK和SRK/T WK呈近视漂移,其余公式呈远视漂移;Holladay 1 WK和除Pearl-DGS外的6种新一代公式表现最佳(RMSAE<0.53),优于传统公式。

要点

  • Hoffer QST、Holladay 1 WK和SRK/T WK在高度近视眼中呈近视漂移。
  • Haigis、Hoffer Q和Holladay 1呈较大远视误差(≥0.27 D)。
  • Holladay 1 WK和除Pearl-DGS外的6种新一代公式RMSAE<0.53,预测准确性优于传统公式。

核心结论

  • 新一代人工晶状体屈光度计算公式和Holladay 1 WK在高度近视眼中较传统公式具有更优的预测准确性。

研究设计与样本

  • 日本4个手术中心的回顾性病例系列,纳入326例患者的326眼,眼轴长度≥26.0 mm。
  • 所有患眼接受标准化超声乳化联合囊袋内人工晶状体植入术,由经验丰富的白内障手术医师在表面麻醉下完成。
  • 主要结局指标为术后球镜等效预测误差(SEQ-PE),采用均方根绝对误差(RMSAE)和Eyetemis在线分析工具评估13种公式的预测性能。

主要发现

  • 平均眼轴长度为27.28±0.98 mm。
  • Hoffer QST、Holladay 1 WK和SRK/T WK在SEQ-PE中呈近视漂移,其他公式呈远视漂移。
  • Haigis、Hoffer Q和Holladay 1表现出相对较大的远视误差(≥0.27 D)。
  • Hoffer Q和Holladay 1的RMSAE超过0.7,而Holladay 1 WK和除Pearl-DGS外的6种新一代公式表现最佳(RMSAE<0.53)。

关键数值与推荐

  • 高度近视眼定义为眼轴长度26.0 mm或更长。
  • 传统公式包括Haigis、Hoffer Q、Holladay 1、SRK/T及Wang-Koch调整公式(Holladay 1 WK、SRK/T WK)。
  • 新一代公式包括Barrett Universal II、EVO 2.0、Hill-RBF、Hoffer QST、Kane、Cooke K6和Pearl-DGS。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the refractive prediction accuracy of 13 intraocular lens (IOL) power calculation formulas, including 7 new-generation formulas available on the European Society of Cataract and Refractive Surgeons (ESCRS) calculator, in highly myopic eyes with axial lengths (AL) of 26.0 mm or longer, through a multicenter study in Japan. DESIGN: A retrospective case series. SUBJECTS: The study included 326 eyes of 326 patients at 4 surgical sites in Japan. METHODS: All patients underwent comprehensive preoperative ophthalmic evaluations, including slit-lamp examination and fundoscopy by ophthalmologists. Corrected distance visual acuity and intraocular pressure were assessed by certified orthoptists. Standard phacoemulsification with intraocular lens implantation in the capsular bag was performed under topical anesthesia by experienced cataract surgeons. MAIN OUTCOME MEASURES: Postoperative spherical equivalent prediction error (SEQ-PE) was assessed for 13 formulas, including traditional formulas (Haigis, Hoffer Q, Holladay 1, SRK/T, Wang-Koch (WK) adjustment formulas for Holladay 1 [Holladay 1 WK] and SRK/T [SRK/T WK]) and new-generation formulas (Barrett Universal II, EVO 2.0, Hill-RBF, Hoffer QST, Kane, Cooke K6, Pearl-DGS). Predictive performance was evaluated using root-mean-square absolute error (RMSAE) and the Eyetemis online analysis tool. RESULTS: The mean AL was 27.28 ± 0.98 mm. The Hoffer QST, Holladay 1 WK, and SRK/T WK demonstrated myopic shifts, whereas other formulas showed a hyperopic shift in SEQ-PE. The Haigis, Hoffer Q, and Holladay 1 exhibited relatively large hyperopic errors (≥0.27 D). RMSAE exceeded 0.7 in the Hoffer Q and Holladay 1, whereas the best performance (RMSAE <0.53) was observed in the Holladay 1 WK and 6 new-generation formulas, except for the Pearl-DGS. CONCLUSIONS: New-generation IOL power calculation formulas and the Holladay 1 WK offer superior predictive accuracy in highly myopic eyes compared with traditional formulas.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Kinoshita M, Goto S, Mori Y, et al. Accuracy of New-Generation Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes: A Multicenter Study in Japan. Am J Ophthalmol. 2025. PMID: 40796023. doi:10.1016/j.ajo.2025.08.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。