文献速递眼底病与葡萄膜炎

自适应光学扫描激光检眼镜检测糖尿病及糖尿病视网膜病变中的视网膜光感受器与小动脉改变

RETINAL PHOTORECEPTORS AND ARTERIOLES ALTERATIONS DETECTED USING ADAPTIVE OPTICS SCANNING LASER OPHTHALMOSCOPY IN DIABETES AND DIABETIC RETINOPATHY.
PubMed 文献 · Retina · 2026-01-01

在广东糖尿病视网膜病变多组学研究纳入的30名受试者中,采用自适应光学扫描激光检眼镜结合人工智能算法定量分析光感受器形态并手动评估小动脉形态,发现黄斑区光感受器细胞密度降低与小动脉壁增厚等改变随糖尿病及非增殖期糖尿病视网膜病变进展而出现。

要点

  • 黄斑区光感受器细胞密度降低与糖尿病(P=0.033)及糖尿病视网膜病变(P=0.006)相关。
  • 小动脉壁厚度在糖尿病患者中显著增加(P<0.001),并随糖尿病视网膜病变出现进一步增加(P=0.018)。
  • 糖尿病视网膜病变组壁腔比较对照组显著增大(P=0.011),小视网膜小动脉的小动脉指数比在三组间差异显著。

核心结论

  • 自适应光学扫描激光检眼镜成像可显示糖尿病视网膜病变进展过程中的视网膜光感受器和小动脉改变,可能作为糖尿病患者解剖或功能视网膜变化的预测指标。

研究设计与样本

  • 研究纳入广东糖尿病视网膜病变多组学研究中的30名受试者(健康对照9例、糖尿病11例、糖尿病视网膜病变10例),平均(标准差)年龄66.33(7.02)岁。
  • 采用自适应光学扫描激光检眼镜进行图像采集,基于人工智能的算法定量分析光感受器形态(锥体密度、间距和规则性),手动评估血管形态(内径、外径、壁厚度、壁腔比),并推导小动脉指数比以评估小动脉重塑。
  • 采用广义估计方程比较健康对照组、糖尿病组和糖尿病视网膜病变组之间内径、外径、壁厚度、壁腔比及小动脉指数比的差异。

主要发现

  • 黄斑区光感受器细胞密度显著降低与糖尿病(P=0.033)及糖尿病视网膜病变(P=0.006)相关。
  • 观察到小动脉壁厚度显著增加,在糖尿病患者小动脉节段中明显(P<0.001),并随糖尿病视网膜病变出现而进一步增加(P=0.018)。
  • 糖尿病视网膜病变组壁腔比较对照组显著增大(P=0.011)。
  • 小视网膜小动脉的小动脉指数比在糖尿病视网膜病变组(P<0.001)、糖尿病组(P=0.024)和对照组之间差异显著。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To detect retinal photoreceptors and arterioles alterations among individuals with diabetes mellitus (DM) and nonproliferative diabetic retinopathy (DR) at cellular resolution. METHODS: Thirty subjects were recruited in the Guangdong Diabetic Retinopathy Multiple-omics Study. Adaptive optics scanning laser ophthalmoscopy was adopted for image acquisition. An AI-based algorithm conducted quantitative analyses of photoreceptor morphology, including cone density, spacing, and regularity. Vessel morphology (inner diameter, outer diameter, wall thickness, wall-to-lumen ratio) was manually assessed. The arteriolar index ratio was derived to assess arteriolar remodeling. Generalized estimating equation was used to compare the differences of inner diameter, outer diameter, wall thickness, wall-to-lumen ratio, and the arteriolar index ratio among healthy control, DM, and DR groups. RESULTS: Thirty patients, consisting of 9 healthy controls, 11 with DM, and 10 with DR, were evaluated (mean [SD] age, 66.33 [7.02]). A significant reduction in photoreceptor cell density in macular areas correlated with the presence of DM ( P = 0.033) and DR ( P = 0.006). Notably, a significant increase of the wall thickness was observed. These variations were pronounced in the arteriole segments of diabetic patients ( P < 0.001) and escalated with the presence of DR ( P = 0.018). Accounting for wall-to-lumen ratio, the DR group showed a significantly larger ratio comparing to control group ( P = 0.011). The arteriolar index ratio in small retinal arterioles differed significantly among DR ( P < 0.001), DM ( P = 0.024), and control groups. CONCLUSION: Adaptive optics scanning laser ophthalmoscopy imaging showed delineating retinal photoreceptor and arteriolar alterations throughout DR progression, potentially serving as a predictive measure for anatomical or functional retinal changes in patients with DM and DR.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Su T, Lai C, Du Z, et al. RETINAL PHOTORECEPTORS AND ARTERIOLES ALTERATIONS DETECTED USING ADAPTIVE OPTICS SCANNING LASER OPHTHALMOSCOPY IN DIABETES AND DIABETIC RETINOPATHY. Retina. 2026. PMID: 40865080. doi:10.1097/IAE.0000000000004647

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。