基于MRI对间歇性外斜视患者双眼集合状态下眼外肌改变的初步观察
横断面研究纳入11例间歇性外斜视患者(22只眼)与10名年龄性别匹配的健康对照(20只眼),用MRI弥散加权成像测量正前方注视与集合注视时内直肌、外直肌和视神经的标准化DWI值。健康对照组内直肌集合注视时标准化DWI值较正前方注视升高且有统计学意义(P<0.05),IXT组无统计学意义(P>0.05)。作者结论为IXT患者集合时内直肌标准化DWI值改变低于健康人。
要点
- 健康对照内直肌标准化DWI值集合注视0.97(0.87,1.20)高于正前方注视0.86(0.72,0.97),差异有统计学意义(P<0.05)。
- IXT组内直肌标准化DWI值集合注视0.81(0.69,1.08)与正前方注视0.77(0.72,0.93)差异无统计学意义(P>0.05)。
- IXT组集合注视时内直肌标准化DWI值改变与斜视度数呈负相关趋势(r=-0.58,P=0.059)。
核心结论
- 间歇性外斜视患者在集合注视时内直肌的标准化DWI值改变低于健康人。
研究设计与样本
- 横断面研究,2023年1至9月在安徽医科大学第一附属医院纳入确诊IXT患者11例(22只眼,男6例、女5例,年龄24±4岁)为IXT组。
- 同期从安徽医科大学招募健康对照10例(20只眼,男4例、女6例,年龄24±1岁),两组年龄和性别分布差异均无统计学意义(均P>0.05)。
- 采用MRI轴位扫描测量双眼内直肌、外直肌和视神经在正前方注视与双眼集合注视时的DWI信号强度值,比较标准化DWI值。
主要发现
- 健康对照组内直肌标准化DWI值正前方注视为0.86(0.72,0.97),集合注视为0.97(0.87,1.20),差异有统计学意义(P<0.05)。
- IXT组内直肌标准化DWI值正前方注视为0.77(0.72,0.93),集合注视为0.81(0.69,1.08),差异无统计学意义(P>0.05)。
- IXT组集合注视时内直肌标准化DWI值改变与斜视度数的相关系数r=-0.58(P=0.059)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To investigate changes in diffusion-weighted imaging (DWI) of extraocular muscles in patients with intermittent exotropia (IXT) during binocular convergence using MRI, and to explore the imaging characteristics of extraocular muscle alterations in IXT. Methods: It was a cross-sectional study. Patients diagnosed with IXT at the First Affiliated Hospital of Anhui Medical University from January 2023 to September 2023 were enrolled as the IXT group, with age-and sex-matched healthy individuals recruited as the control group. Axial MRI scanning was used to measure DWI signal intensity values of the medial rectus, lateral rectus, and optic nerve during primary gaze and convergence gaze. The normalized DWI values between the two groups and two gaze conditions were compared. The correlation between normalized DWI value changes and the degree of strabismus in the IXT group was analyzed. Normally distributed data were analyzed using independent and paired t-tests, while non-normally distributed data were evaluated with Mann-Whitney and Wilcoxon signed-rank tests. Pearson correlation analysis was used to assess the relationship between DWI values and the degree of strabismus. Results: Eleven patients (22 eyes) were included in the IXT group (six males, five females; mean age, 24±4 years), and 10 healthy controls (20 eyes) were included (four males, six females; mean age, 24±1 years). Baseline characteristics were comparable between groups (P>0.05). In the control group, the normalized DWI value of the medial rectus was 0.86 (0.72, 0.97) during primary gaze and 0.97 (0.87, 1.20) during convergence gaze, with a significant difference (P<0.05). In the IXT group, the normalized DWI value of the medial rectus was 0.77 (0.72, 0.93) during primary gaze and 0.81 (0.69, 1.08) during convergence gaze, with no significant difference (P>0.05). A negative correlation trend was observed between changes in normalized DWI values of the medial rectus during convergence gaze and the degree of strabismus in the IXT group (r=-0.58, P=0.059). Conclusion: Patients with IXT exhibit significantly reduced changes in normalized DWI values of the medial rectus during binocular convergence compared to healthy controls. 目的: 基于MRI探讨间歇性外斜视(IXT)患者在双眼集合状态下眼外肌的变化。 方法: 横断面研究。收集2023年1至9月在安徽医科大学第一附属医院确诊为间歇性外斜视的患者(IXT组),同期从安徽医科大学招募健康志愿者(健康对照组)。采用MRI轴位扫描观察两组受试者的双眼内直肌、外直肌和视神经在正前方注视或双眼集合注视时的弥散加权成像(DWI)信号强度值。比较两组间的标准化DWI值差异,以及在不同注视状态下的标准化DWI值差异,并分析IXT组眼外肌标准化DWI值改变与斜视度数间的相关性。采用独立样本t检验、Mann-Whitney U检验、Wilcoxon符号秩检验及Pearson相关性分析等进行统计学分析。 结果: IXT组纳入患者11例(22只眼),其中男性6例,女性5例;年龄(24±4)岁;健康对照组纳入受试者10例(20只眼),其中男性4例,女性6例,年龄(24±1)岁。两组间年龄和性别分布差异均无统计学意义(均P>0.05)。健康对照组在正前方注视时内直肌的标准化DWI值为0.86(0.72,0.97),在集合注视时内直肌的标准化DWI值为0.97(0.87,1.20),差异有统计学意义(P<0.05)。IXT组在正前方注视时内直肌的标准化DWI值为0.77(0.72,0.93),在集合注视时内直肌的标准化DWI值为0.81(0.69,1.08),差异无统计学意义(P>0.05)。IXT组在集合注视时内直肌标准化DWI值的改变与斜视度数的相关系数r=-0.58(P=0.059)。 结论: 间歇性外斜视患者在集合注视时内直肌的标准化DWI值改变低于健康人。.
引用
- Xia L, Feng LX. [Preliminary observations of extraocular muscle changes in patients with intermittent exotropia during binocular convergence based on MRI]. Zhonghua Yan Ke Za Zhi. 2025. PMID: 40605305. doi:10.3760/cma.j.cn112142-20241028-00481
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。