文献速递角膜与眼表疾病

偏振敏感光学相干断层扫描检测圆锥角膜交联术后早期结构变化

Early Structural Changes in Keratoconic Eyes After Corneal Crosslinking Detected by Polarization-Sensitive Optical Coherence Tomography.
PubMed 文献 · Am J Ophthalmol · 2025-06-27

该介入性病例系列纳入8例双眼圆锥角膜患者的8只眼,采用上皮去除交联(10分钟羟丙基甲基纤维素核黄素浸泡后9 mW/cm²紫外线照射10分钟),用偏振敏感光学相干断层扫描(PS-OCT)在基线、术后即刻、1周、1个月和3个月评估偏振均匀度(DOPU)。结果显示交联后角膜基质出现时间依赖性偏振保持背向散射模式,3个月时DOPU较1个月下降,提示基质结构重塑;作者认为这些形态学征象可能作为预测治疗结局或识别无应答者的未来生物标志物。

要点

  • 上皮去除交联后1周PS-OCT显示环形偏振保持,前、中、后基质DOPU分别为0.720±0.015、0.767±0.016(P<.01)、0.744±0.010。
  • 交联后1个月中基质DOPU 0.779±0.023(较1周P>.05),后基质0.802±0.016(较1周P=.001),环形直径减小。
  • 交联后3个月前、中、后基质DOPU分别降至0.669±0.007、0.688±0.011(较基线P=.05)、0.734±0.019(均较1个月P<.001)。

核心结论

  • PS-OCT显示圆锥角膜交联后不仅前、中基质,后基质也发生较既往文献描述更深刻的结构重塑。
  • 这些新的形态学征象可能作为未来预测治疗结局或识别无应答者的生物标志物。

研究设计与样本

  • 介入性病例系列,纳入8例双侧圆锥角膜患者的8只眼。
  • 行上皮去除交联:10分钟羟丙基甲基纤维素核黄素浸泡后9 mW/cm²紫外线照射10分钟。
  • 采用Scheimpflug、前节OCT和PS-OCT成像,PS-OCT光栅扫描在基线、交联后即刻、1周、1个月和3个月进行。

主要发现

  • Scheimpflug和前节OCT显示交联后角膜曲率变化:Kmax在1个月较基线增加(P=.01),3个月较基线降低(P=.02),1个月出现分界线后角膜结构恢复正常。
  • PS-OCT显示交联后角膜基质出现时间依赖性偏振保持背向散射模式:1周时前、中、后基质DOPU分别为0.720±0.015、0.767±0.016(P<.01)、0.744±0.010。
  • 1个月时前、中、后基质DOPU分别为0.745±0.017、0.779±0.023(较1周P>.05)、0.802±0.016(较1周P=.001),环形直径减小(前 vs 中P=.03;后 vs 1周P=.04)。
  • 3个月时前、中、后基质DOPU分别降至0.669±0.007(较1个月P<.001)、0.688±0.011(较1个月P<.001;较基线P=.05)、0.734±0.019(较1个月P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess early structural changes in keratoconic corneas secondary to epi-off corneal crosslinking (CXL) using polarization-sensitive optical coherence tomography (PS-OCT). DESIGN: Interventional case series. SUBJECTS: Eight eyes of 8 subjects with bilateral keratoconus were included. METHODS: Epi-off CXL using 10 minutes of hydroxypropyl methylcellulose-based riboflavin soaking before 10 minutes of ultraviolet irradiation (9 mW/cm²) was performed. Eyes were imaged using conventional Scheimpflug, anterior-segment optical coherence tomography (AS-OCT), and PS-OCT imaging. PS-OCT raster scanning was performed before (baseline [BSL]) and immediately after CXL, and 1 week, 1 month, and 3 months after CXL. MAIN OUTCOME MEASURES: Degrees of polarization uniformity (DOPU) images of each visit were evaluated as indicator for structural changes. Findings were compared with corresponding AS-OCT imaging. RESULTS: Scheimpflug and AS-OCT imaging revealed expected CXL-induced changes in corneal curvature (compared with BSL: Kmax increase at 1 month, P = .01; Kmax decrease at 3 months, P = .02) and the appearance of a demarcation line 1 month after CXL followed by normalization of the corneal structure. PS-OCT revealed a distinct, time-dependent pattern of polarization-maintaining backscattering in the corneal stroma secondary to CXL. At 1 week, ring-shaped polarization preservation appeared: anterior stroma DOPU 0.720 ± 0.015, mid-stroma 0.767 ± 0.016 (P < .01), and posterior 0.744 ± 0.010. At 1 month, DOPU values were 0.745 ± 0.017, 0.779 ± 0.023 (P > .05 vs 1 week), and 0.802 ± 0.016 (P = .001 vs 1 week), respectively, with decreasing ring diameters (P = .03 anterior vs mid; P = .04 posterior vs 1 week). At 3 months, DOPU decreased to 0.669 ± 0.007 (P < .001 vs 1 month), 0.688 ± 0.011 (P < .001 vs 1 month; P = .05 vs BSL), and 0.734 ± 0.019 (P < .001 vs 1 month), indicating evolving stromal structural changes post-crosslinking. CONCLUSIONS: By using PS-OCT, the tissue response to CXL of keratoconic eyes was investigated in high detail, taking advantage of the polarizing properties of corneal tissue. Findings suggest a more profound restructuring not only in the anterior and mid but also in the posterior stroma after CXL than previously described in the literature. Such new morphologic signs might serve as future biomarkers to predict therapeutic outcomes or detect nonresponders.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Lammer J, Aschauer J, Beer F, et al. Early Structural Changes in Keratoconic Eyes After Corneal Crosslinking Detected by Polarization-Sensitive Optical Coherence Tomography. Am J Ophthalmol. 2025. PMID: 40582688. doi:10.1016/j.ajo.2025.06.045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。