文献速递眼底病与葡萄膜炎

一种无需头位的小儿黄斑裂孔手术新技术的疗效:在空气下于翻转内界膜瓣上应用黏弹性装置

OUTCOMES OF A NOVEL TECHNIQUE THAT DOES NOT REQUIRE HEAD POSITION IN MACULAR HOLE SURGERY: Application of Viscoelastic on an Inverted Internal Limiting Membrane Flap Under Air.
PubMed 文献 · Retina · 2025-01-01

该研究报道了一种新技术,即在空气下将弥散性黏弹性装置注射到翻转的颞侧内界膜瓣上以闭合黄斑裂孔,且不要求术后头位。共纳入106例患者114眼,初次黄斑裂孔闭合率达98.2%,其中两例经二次手术闭合;U型闭合占71.9%,V型占20.1%,W型占8%。最佳矫正视力显著改善(P < 0.001),眼压无显著变化(P = 0.881)。

要点

  • 在空气下将弥散性黏弹性装置应用于翻转的颞侧内界膜瓣上,无需术后头位。
  • 114眼中初次黄斑裂孔闭合112眼(98.2%),两例经二次手术闭合。
  • 闭合形态为U型71.9%、V型20.1%、W型8%。

核心结论

  • 该技术增强瓣稳定性,促进黄斑裂孔闭合,并消除术后头位需求,获得良好的解剖和功能结果,提高患者舒适度。

研究设计与样本

  • 研究纳入106例患者114眼,所有眼均制作颞侧内界膜瓣并用全氟化碳液体翻转覆盖于黄斑裂孔上;经流体-空气交换后,在空气下将弥散性黏弹性装置应用于翻转瓣周围,覆盖2至3个视盘直径区域,随后行空气-六氟化硫交换并关闭巩膜切口;术后不建议头位;收集术前黄斑裂孔大小、最佳矫正视力、黄斑裂孔闭合率及闭合形态数据。

主要发现

  • 初次黄斑裂孔闭合112眼(98.2%),两例经二次手术闭合。
  • U型闭合占71.9%,V型闭合占20.1%,W型闭合占8%。
  • 最佳矫正视力显著改善(P < 0.001),眼压无显著变化(P = 0.881)。

关键数值与推荐

  • 初次黄斑裂孔闭合率为98.2%(112/114眼)。
  • 闭合形态分布:U型71.9%、V型20.1%、W型8%。
  • 最佳矫正视力改善P < 0.001,眼压变化P = 0.881。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report outcomes of a novel technique involving the injection of a dispersive viscoelastic device on to inverted temporal internal limiting membrane flap under air for macular hole (MH) closure, without requiring postoperative head positioning. METHODS: A temporal internal limiting membrane flap was created in all patients and inverted over the MH with perfluorocarbon liquid. After a fluid-air exchange, a perfluorocarbon liquid-air exchange was done. Afterward, a dispersive viscoelastic agent was applied around the inverted flap under air, covering an area of two-to-three-disk diameters. An air-sulfur hexafluoride exchange was then performed, and the sclerotomies were closed. No head positioning was advised postoperatively. Data on preoperative MH size, best-corrected visual acuity, MH closure rate, and closure pattern were collected. RESULTS: The study included 114 eyes from 106 patients. Initial MH closure was achieved in 112 eyes (98.2%), with two cases closed after a second surgery. U-shaped closure occurred in 71.9%, V-shaped in 20.1%, and W-shaped in 8%. Significant best-corrected visual acuity improvement was observed ( P < 0.001), with no significant change in intraocular pressure ( P = 0.881). CONCLUSION: This technique enhances flap stabilization, facilitates MH closure, and eliminates the need for postoperative head positioning, leading to favorable anatomical and functional outcomes with improved patient comfort.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Seyyar SA, Saygılı O, Çömez A, et al. OUTCOMES OF A NOVEL TECHNIQUE THAT DOES NOT REQUIRE HEAD POSITION IN MACULAR HOLE SURGERY: Application of Viscoelastic on an Inverted Internal Limiting Membrane Flap Under Air. Retina. 2025. PMID: 40700650. doi:10.1097/IAE.0000000000004609

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。