文献速递青光眼

基于簇特征预测可重复的青光眼视野缺损

Prediction of repeatable glaucomatous visual field defects based on cluster characteristics.
PubMed 文献 · Br J Ophthalmol · 2025-11-20

本回顾性队列研究纳入103例患者共197只眼(健康、疑似或早期青光眼),评估初次视野检查中缺损簇的位置、大小和体积能否预测随后两次检查中的可重复缺损。结果显示,4424个p<5%缺损位点中仅1189个(26.9%)可重复;簇大小和体积的AUC均为0.80(CI 0.76至0.85),在95%特异性下不同概率水平有相应大小阈值。结论认为簇特征可能有助于识别可重复缺损风险较高的眼。

要点

  • 初次视野p<5%缺损位点中仅26.9%(1189/4424)在随后两次检查中可重复。
  • 簇大小和体积预测簇内可重复缺损的AUC均为0.80(CI 0.76至0.85)。
  • 95%特异性下,p<5%簇>6个位点、p<2%>4个、p<1%>3个、p<0.5%>2个位点预测可重复。

核心结论

  • 初次视野检查中缺损簇的位置、大小和体积可能预测随后检查中的可重复性,或有助于区分可重复缺损风险较高的眼。

研究设计与样本

  • 回顾性队列研究,纳入103例健康、疑似或早期青光眼患者的197只眼。
  • 基于初次视野模式偏差概率网格,按四个概率水平(p<5%、p<2%、p<1%、p<0.5%)定义簇数量、大小(相邻缺损位点数)和体积(对应总偏差值之和)。

主要发现

  • 4424个p<5%缺损位点中仅1189个(26.9%)可重复。
  • 簇大小预测簇内可重复缺损的AUC为0.80(CI 0.76至0.85),簇体积AUC为0.80(CI 0.76至0.85)。
  • 95%特异性下,基于初次簇大小预测簇内可重复位点的最优阈值为:p<5%时>6个位点、p<2%时>4个位点、p<1%时>3个位点、p<0.5%时>2个位点。
  • 以中央或周边边缘位点受累定义簇缺损,较整个24-2网格提高了预测价值。

关键数值与推荐

  • p<5%簇大小阈值>6个位点(95%特异性)。
  • p<2%簇大小阈值>4个位点(95%特异性)。
  • p<1%簇大小阈值>3个位点(95%特异性)。
  • p<0.5%簇大小阈值>2个位点(95%特异性)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: This study evaluates if characteristics (eg, location, size, volume) of clusters of defects on an initial visual field (VF) test were predictive of a repeatable defect in the subsequent two tests. METHODS: Retrospective cohort study of 197 eyes of 103 patients with healthy, suspect or early glaucoma. Using the initial VF pattern deviation probability grid, we defined the number of clusters (≥1 location of p<5%) and associated size (number of adjoining defect locations) and volume (sum of corresponding total deviation values) for each cluster stratified by the four probability levels (ie, p<5%; p<2%; p<1% and p<0.5%). RESULTS: Of 4424 locations with a defect of p<5%, only 1189 (26.9%) were repeatable. The size [area under the receiver operating characteristic curve (AUC) 0.80, CI 0.76 to 0.85)] and volume (AUC 0.80, CI 0.76 to 0.85) of clusters were predictive of a repeatable defect within the cluster. The optimal thresholds for predicting a repeatable location within each cluster at 95% specificity based on initial cluster size were >6 locations at p<5%, >4 locations at p<2%, >3 locations at p<1% and >2 locations at p<0.5%. Defining cluster defects by involvement of central or peripheral rim locations improved the predictive value compared with the entire 24-2 grid. CONCLUSION: The location, size and volume of clusters of defects on an initial VF test may be predictive of subsequent repeatability. This may help distinguish eyes with a higher risk of repeatable defects.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Tan JCK, Phu J, Bell K, et al. Prediction of repeatable glaucomatous visual field defects based on cluster characteristics. Br J Ophthalmol. 2025. PMID: 40610047. doi:10.1136/bjo-2025-327416

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。