文献速递白内障与屈光手术

眼轴长度大于28 mm白内障患者超声乳化联合囊袋张力环植入术中人工晶状体屈光力计算公式准确性比较

[Accuracy comparison of intraocular lens power calculation formulas in cataract patients with axial length greater than 28 mm undergoing phacoemulsification with capsular tension ring implantation].
PubMed 文献 · Zhonghua Yan Ke Za Zhi · 2025-01-01

回顾性病例系列研究纳入26例(26只眼)眼轴长度>28 mm且行超声乳化联合囊袋张力环植入的白内障患者,比较Barrett Universal Ⅱ、Haigis和SRK/T公式的预测准确性。Barrett Universal Ⅱ公式平均预测误差最小(-0.08±0.28)D,平均绝对误差最低(0.22 D),预测误差在±0.25 D和±0.50 D区间内眼数百分比显著高于Haigis和SRK/T公式(P<0.05)。

要点

  • 眼轴>28 mm联合囊袋张力环植入患者中Barrett Universal Ⅱ公式平均绝对误差0.22 D,低于Haigis 0.43 D和SRK/T 0.45 D(P<0.05)。
  • 预测误差±0.25 D区间内Barrett Universal Ⅱ公式19/26眼(73.08%),显著高于Haigis 10/26眼(38.46%)和SRK/T 8/26眼(30.77%)(P<0.05)。
  • 预测误差±0.50 D区间内Barrett Universal Ⅱ公式24/26眼,高于Haigis 17/26眼和SRK/T 16/26眼(P<0.05)。

核心结论

  • 在眼轴长度>28 mm且联合植入囊袋张力环的白内障患者中,Barrett Universal Ⅱ公式预测人工晶状体屈光力准确性更高,平均预测误差更接近0,平均绝对误差更小,可作为此类患者的优先选择。

研究设计与样本

  • 回顾性病例系列研究,纳入2023年1至10月于首都医科大学附属北京同仁医院眼科接受治疗的26例(26只眼)眼轴长度>28 mm的白内障患者,所有患者行超声乳化白内障吸除联合囊袋张力环植入术。

主要发现

  • Barrett Universal Ⅱ公式平均预测误差为(-0.08±0.28)D,Haigis公式为(0.35±0.43)D,SRK/T公式为(0.31±0.47)D。
  • Barrett Universal Ⅱ公式平均绝对误差为0.22 D,显著低于Haigis公式0.43 D和SRK/T公式0.45 D(P<0.05)。
  • 预测误差±0.25 D区间内Barrett Universal Ⅱ公式19/26眼(73.08%),显著高于Haigis公式10/26眼(38.46%)和SRK/T公式8/26眼(30.77%)(P<0.05)。
  • 预测误差±0.50 D区间内Barrett Universal Ⅱ公式24/26眼(原文此处写作88.89%,按上下文应为92.31%),高于Haigis公式17/26眼(65.38%)和SRK/T公式16/26眼(61.54%)(P<0.05)。
  • 预测误差±1.00 D区间内Barrett Universal Ⅱ公式26/26眼(100%),Haigis公式25/26眼(96.15%),SRK/T公式24/26眼(92.31%)。

关键数值与推荐

  • 预测误差±0.25 D区间内眼数百分比:Barrett Universal Ⅱ公式73.08% vs Haigis公式38.46% vs SRK/T公式30.77%(P<0.05)。
  • 预测误差±0.50 D区间内眼数百分比:Barrett Universal Ⅱ公式88.89%(原文此处写作88.89%,按上下文应为92.31%)vs Haigis公式65.38% vs SRK/T公式61.54%(P<0.05)。
  • 平均绝对误差:Barrett Universal Ⅱ公式0.22 D vs Haigis公式0.43 D vs SRK/T公式0.45 D(P<0.05)。

临床怎么用

  • 作者认为,在眼轴长度>28 mm且联合植入囊袋张力环的白内障患者中,Barrett Universal Ⅱ公式可作为优先选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To evaluate the accuracy of the Barrett Universal Ⅱ, Haigis, and SRK/T formulas for intraocular lens (IOL) power calculation in cataract patients with axial length >28 mm undergoing phacoemulsification combined with capsular tension ring implantation. Methods: A retrospective case series study was conducted. Data from 26 eyes (26 patients) with cataract (axial length>28 mm), treated at the Department of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, from January to October 2023 were analyzed. Patients had a median age of 59 years (interquartile range: 51-63), with 14 males and 12 females. All patients underwent biometric measurements using the IOL Master, had uneventful surgeries without intraoperative or postoperative complications, and completed objective refraction at 1 month postoperatively. Primary outcomes included mean prediction error (MPE), mean absolute error (MAE), and the percentage of eyes with prediction errors within ±0.25 D,±0.50 D, and ±1.00 D. Inter-group comparisons were performed using the one-way ANOVA with Bonferroni correction, and categorical data were analyzed using the Chi-square test. Results: The Barrett Universal Ⅱ formula yielded the smallest MPE of (-0.08±0.28) D, compared to (0.35±0.43) D for Haigis and (0.31±0.47) D for SRK/T. The MAE was lowest with Barrett Universal Ⅱ (0.22 D), significantly lower than Haigis (0.43 D) and SRK/T (0.45 D) (P<0.05). Within the ±0.25 D prediction error range, Barrett Universal Ⅱ achieved 19/26 eyes (73.08%), significantly higher than Haigis (10/26, 38.46%) and SRK/T (8/26, 30.77%) (P<0.05). For the ±0.50 D range, Barrett Universal Ⅱ included 24/26 eyes (92.31%), surpassing Haigis (17/26, 65.38%) and SRK/T (16/26, 61.54%) (P<0.05). Within ±1.00 D, Barrett Universal Ⅱ achieved 26/26 eyes (100%), compared to Haigis (25/26, 96.15%) and SRK/T (24/26, 92.31%). Conclusions: In cataract patients with axial length >28 mm and capsular tension ring implantation, the Barrett Universal Ⅱ formula is recommended for its superior accuracy in IOL power calculation, with an MPE closer to zero, lower MAE, and significantly higher percentages of eyes within ±0.25 D and ±0.50 D prediction error ranges compared to Haigis and SRK/T. 目的: 探讨超声乳化白内障吸除联合囊袋张力环植入术中Barrett Universal Ⅱ、Haigis和SRK/T 3种人工晶状体屈光力计算公式的准确性。 方法: 回顾性病例系列研究。纳入2023年1至10月于首都医科大学附属北京同仁医院眼科接受治疗的26例(26只眼)眼轴长度>28 mm的白内障患者资料。患者年龄为59(51,63)岁,男性14例,女性12例。所有患者均完成眼部生物测量仪检查,手术顺利且无术中及术后并发症,术后1个月完成客观验光检查。主要指标为各公式的平均预测误差、平均绝对误差及预测误差在±0.25 D、±0.50 D和±1.00 D区间内的患眼数及百分比。组间比较采用单因素方差分析及Bonferroni检验,计数资料比较采用卡方检验。 结果: Barrett Universal Ⅱ公式的平均预测误差最小,为(-0.08±0.28)D,Haigis和SRK/T公式分别为(0.35±0.43)和(0.31±0.47)D。Barrett Universal Ⅱ公式的平均绝对误差最小,为0.22 D,显著低于Haigis(0.43 D)和SRK/T(0.45 D)公式(P<0.05)。在预测误差±0.25 D区间内,Barrett Universal Ⅱ公式的眼数为19/26(73.08%),显著高于Haigis公式的10/26(38.46%)和SRK/T公式的8/26(30.77%)(P<0.05)。当预测误差范围扩大至±0.50 D时,Barrett Universal Ⅱ公式的眼数为24/26(88.89%),同样高于Haigis公式的17/26(65.38%)和SRK/T公式的16/26(61.54%)(P<0.05)。Barrett Universal Ⅱ公式的预测误差在±1.00 D区间内的眼数为26/26(100%),Haigis公式为25/26(96.15%),SRK/T公式为24/26(92.31%)。 结论: 在眼轴长度>28 mm且联合植入囊袋张力环的白内障患者中,Barrett Universal Ⅱ公式在预测人工晶状体屈光力方面具有更高的准确性,其平均预测误差更接近0,平均绝对误差更小,且在预测误差±0.25 D和±0.50 D区间内的眼数百分比显著高于Haigis和SRK/T公式,可作为此类患者的优先选择。.

来源:Zhonghua Yan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Dong CB, Zhao HY, Yang X, et al. [Accuracy comparison of intraocular lens power calculation formulas in cataract patients with axial length greater than 28 mm undergoing phacoemulsification with capsular tension ring implantation]. Zhonghua Yan Ke Za Zhi. 2025. PMID: 40484850. doi:10.3760/cma.j.cn112142-20241017-00458

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。