文献速递白内障与屈光手术

基于扫频源OCT测量眼内参数评估白内障术后眼内残余散光

[Evaluation of residual internal astigmatism after cataract surgery based on intraocular parameters measured by swept-source OCT].
PubMed 文献 · Zhonghua Yan Ke Za Zhi · 2025-01-01

回顾性病例系列研究纳入122例白内障患者(122只眼),使用扫频源OCT测量非散光矫正型人工晶状体植入术前及术后1个月的倾斜与偏心。结果显示眼内残余散光与人工晶状体倾斜角度正相关,左眼残余散光和倾斜角度均显著大于右眼,偏心距离与残余散光无关。

要点

  • 非散光矫正型人工晶状体植入术后,眼内残余散光与人工晶状体倾斜角度正相关,与偏心距离无关。
  • 左眼眼内残余散光绝对值(0.81±0.43)D显著大于右眼(0.56±0.31)D,P<0.001。
  • 左眼人工晶状体倾斜角度(5.51°±1.59°)大于右眼(4.58°±1.36°),P=0.001。

核心结论

  • 非散光矫正型人工晶状体植入术后眼内残余散光与人工晶状体倾斜角度显著相关,而与偏心距离无关。
  • 人工晶状体倾斜是影响术后视觉质量的重要因素。
  • 左眼人工晶状体倾斜角度和眼内残余散光均显著大于右眼,眼别可能是影响人工晶状体位置及术后视觉质量的重要因素。

研究设计与样本

  • 回顾性病例系列研究,纳入2022年10月至2023年9月天津医科大学眼科医院122例白内障患者(122只眼,右眼67只,左眼55只)。
  • 患者年龄为(68.80±8.82)岁,男性57例,女性65例。
  • 所有患者均接受白内障超声乳化联合非散光矫正型人工晶状体植入术。
  • 术前和术后1个月使用扫频源相干光层析成像术(SS-OCT)测量晶状体和人工晶状体的偏心位移、倾斜矢量及前节参数。

主要发现

  • 总体眼内残余散光绝对值为(0.67±0.39)D,左眼(0.81±0.43)D显著大于右眼(0.56±0.31)D,P<0.001。
  • 总体人工晶状体倾斜角度为5.00°±1.54°,左眼(5.51°±1.59°)大于右眼(4.58°±1.36°),P=0.001。
  • 眼内残余散光与人工晶状体倾斜角度呈正相关(r=0.22,P=0.016)。
  • 多元回归显示人工晶状体倾斜角度每增加1°,眼内残余散光增加0.06 D(β=0.06,P=0.016)。
  • 前房深度(r=-0.24,P=0.008)和眼轴长度(r=-0.38,P<0.001)与人工晶状体倾斜角度呈负相关,人工晶状体屈光度数(r=0.37,P<0.001)与倾斜角度呈正相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To explore the influencing factors of intraocular residual astigmatism (RIA) after the implantation of non-toric intraocular lens (IOL), and to analyze the differences in the positional characteristics of the IOL and RIA between the eyes. Methods: This was a retrospective case series study. The data of 122 cataract patients (122 eyes, 67 right eyes and 55 left eyes) in the Eye Hospital of Tianjin Medical University from October 2022 to September 2023 were included. The patients' age was (68.80±8.82) years old, with 57 males and 65 females. All patients underwent phacoemulsification combined with the implantation of non-toric IOL. Swept-source optical coherence tomography (SS-OCT) was used to measure the decentration displacement, tilt vector of the lens and IOL, and anterior segment parameters before and 1 month after the surgery. The main indicators included the magnitude and direction of RIA, the tilt vector and decentration displacement of the IOL. Results: The absolute value of the overall RIA was (0.67±0.39) D. The absolute value of RIA in the left eyes [(0.81±0.43) D] was significantly greater than that in the right eyes [(0.56±0.31) D, P<0.001]. The tilt angle of the IOL was 5.00°±1.54°. The tilt angle in the left eyes (5.51°±1.59°) was greater than that in the right eyes (4.58°±1.36°, P=0.001). RIA was positively correlated with the tilt angle of the IOL (r=0.22, P=0.016). Multiple regression showed that for every 1° increase in the tilt angle of the IOL, RIA increased by 0.06 D (β=0.06, P=0.016). The anterior chamber depth (r=-0.24, P=0.008) and axial length (r=-0.38, P<0.001) were negatively correlated with the tilt angle of the IOL, and the refractive power of the IOL (r=0.37, P<0.001) was positively correlated with the tilt angle. Conclusions: After the implantation of non-toric IOL, RIA is significantly correlated with the tilt angle of the IOL, but not with the decentration distance. IOL tilt is an important factor affecting the postoperative visual quality. Both the tilt angle of the IOL and RIA in the left eyes are significantly greater than those in the right eyes. The eye side may be an important factor affecting the position of the IOL and the postoperative visual quality. 目的: 探讨非散光矫正型人工晶状体(IOL)术后眼内残余散光(RIA)的影响因素,并分析眼别在IOL位置特征及RIA方面的差异。 方法: 回顾性病例系列研究。纳入2022年10月至2023年9月天津医科大学眼科医院122例白内障患者(122只眼,右眼67只,左眼55只)的资料,年龄为(68.80±8.82)岁,男性57例,女性65例。所有患者均接受白内障超声乳化联合非散光矫正型IOL植入术。术前和术后1个月使用扫频源相干光层析成像术(SS-OCT)测量晶状体和IOL的偏心位移、倾斜矢量及前节参数,主要指标包括RIA的大小和方向、IOL倾斜矢量及偏心位移。采用Hotelling T²分析比较左右眼在晶状体和IOL的偏心位移、倾斜矢量及前节参数方面的差异,多元线性回归分析IOL倾斜和偏心对RIA的影响。 结果: 总体RIA绝对值为(0.67±0.39)D,左眼RIA绝对值为(0.81±0.43)D,显著大于右眼的(0.56±0.31)D(P<0.001)。总体IOL倾斜角度为5.00°±1.54°,左眼(5.51°±1.59°)大于右眼(4.58°±1.36°)(P=0.001)。RIA与IOL倾斜角度呈正相关(r=0.22,P=0.016),多元回归分析结果显示IOL倾斜角度每增加1°,RIA增加0.06 D(β=0.06,P=0.016)。前房深度(r=-0.24,P=0.008)和眼轴长度(r=-0.38,P<0.001)与IOL倾斜角度呈负相关,IOL屈光度数(r=0.37,P<0.001)与倾斜角度呈正相关。 结论: 非散光矫正型IOL术后RIA与IOL倾斜角度显著相关,而与偏心距离无关,IOL倾斜是影响术后视觉质量的重要因素。左眼IOL倾斜角度和RIA均显著大于右眼,眼别可能是影响IOL位置及术后视觉质量的重要因素。.

来源:Zhonghua Yan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Yin TF, Gao YC, Li YN, et al. [Evaluation of residual internal astigmatism after cataract surgery based on intraocular parameters measured by swept-source OCT]. Zhonghua Yan Ke Za Zhi. 2025. PMID: 40484854. doi:10.3760/cma.j.cn112142-20241030-00484

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。