文献速递白内障与屈光手术

厚晶状体眼白内障术后晶状体位置变化:基于SS-OCT的研究

Lens position change following cataract surgery in eyes with thick lenses: an SS-OCT based study.
PubMed 文献 · Br J Ophthalmol · 2025-09-23

这项前瞻性队列研究纳入90眼,按晶状体厚度(LT)分三组,用SS-OCT测量术后人工晶状体位置变化(δLP)。LT≥5 mm组δLP更负且四种公式均呈近视性预测误差,LT是δLP唯一独立影响因素。

要点

  • LT≥5 mm组δLP为-0.44±0.65 mm,较LT<4 mm组和4 mm≤LT<5 mm组更负,差异有统计学意义(均p<0.05)。
  • LT≥5 mm组四种公式的预测误差均呈近视性,与另两组差异有统计学意义(均p<0.05)。
  • δLP与LT负相关(r=-0.264,p=0.012),与前方深度正相关(r=0.263,p=0.012)。

核心结论

  • 术后人工晶状体向前移动导致厚晶状体眼出现近视性预测误差。

研究设计与样本

  • 前瞻性队列研究,纳入计划行超声乳化及单焦点人工晶状体植入的患者,按LT分为LT<4 mm、4 mm≤LT<5 mm、LT≥5 mm三组,共分析90例90眼。
  • 用眼前节SS-OCT测量δLP,定义为术后人工晶状体位置与术前晶状体赤道面之差,术后至少1年评估四种公式的预测误差。

主要发现

  • 总体平均δLP为-0.12±0.60 mm。
  • LT≥5 mm组δLP为-0.44±0.65 mm,LT<4 mm组为0.02±0.65 mm,4 mm≤LT<5 mm组为0.04±0.49 mm,LT≥5 mm组更负(均p<0.05)。
  • LT≥5 mm组四种公式的预测误差均呈近视性,较LT<4 mm组和4 mm≤LT<5 mm组差异有统计学意义(均p<0.05)。
  • δLP与LT负相关(r=-0.264,p=0.012),与前方深度正相关(r=0.263,p=0.012)。
  • 后退逐步多元线性回归显示LT是δLP唯一独立影响因素(p<0.05);前方深度和δLP是Barrett Universal II公式预测误差的独立影响因素,LT和δLP是其余公式预测误差的独立影响因素(均p<0.05)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the impact of intraocular lens (IOL) positional change following cataract surgery, measured by swept-source optical coherence tomography (SS-OCT) in eyes with different lens thicknesses (LTs), and its influence on the accuracy of IOL power calculation. METHODS: This prospective cohort study enrolled patients who planned to undertake phacoemulsification and monofocal IOL implantation, and were divided into three groups according to the LT (LT<4 mm, 4 mm≤LT<5 mm, LT≥5 mm). Lens position change (δLP), measured by the anterior segment SS-OCT, was defined as the difference between the position of postoperative IOL and the equatorial plane of preoperative lens. The prediction errors (PEs) of Barrett Universal II (BUII), Kane, Emmetropia Verifying Optical and Pearl-DGS formulas were evaluated at least 1 year postoperatively. RESULTS: Totally 90 eyes of 90 patients were analysed. The overall average δLP was -0.12±0.60 mm. Eyes with LT≥5 mm had more negative δLP (-0.44±0.65 vs 0.02±0.65 and 0.04±0.49 mm) and myopic PE of all four formulas than the LT<4 mm and 4 mm≤LT<5 mm groups, respectively (all p<0.05). δLP was negatively correlated with LT (r=-0.264, p=0.012) and positively correlated with anterior chamber depth (ACD) (r=0.263, p=0.012). Backward stepwise multiple linear regression analyses further revealed LT was the only independent influencing factor of δLP (p<0.05). ACD and δLP were the independent influencing factors of the PE with the BUII formula, while LT and δLP were the independent influencing factors of the PE with the other formulas (all p<0.05). CONCLUSION: Postoperative forward IOL movement contributes to myopic PEs of eyes with thick lenses. TRIAL REGISTRATION NUMBER: NCT02182921.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Chen C, Zhou J, Cheng K, et al. Lens position change following cataract surgery in eyes with thick lenses: an SS-OCT based study. Br J Ophthalmol. 2025. PMID: 40461064. doi:10.1136/bjo-2025-327414

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。