文献速递眼底病与葡萄膜炎

绘制影响图谱:人工智能驱动的OCT扫描地图状萎缩量化及其与视觉敏感度丧失的关联

Mapping the impact: AI-driven quantification of geographic atrophy on OCT scans and its association with visual sensitivity loss.
PubMed 文献 · Br J Ophthalmol · 2025-09-23

研究纳入50例年龄相关性黄斑变性继发地图状萎缩患者,在一眼中央8°半径区域内行缺陷映射微视野检查,用AI模型自动分割OCT上的地图状萎缩并与人工标注的眼底自发荧光图像比较。OCT与FAF来源的地图状萎缩范围与微视野检查漏检点比例均呈强相关(ρ=0.85与ρ=0.89),提示OCT自动量化地图状萎缩与全局视觉敏感度丧失相关。

要点

  • OCT自动分割地图状萎缩范围与微视野漏检点比例强相关(ρ=0.85)。
  • FAF手动标注地图状萎缩范围与微视野漏检点比例强相关(ρ=0.89)。
  • 基于OCT与FAF地图状萎缩预测单点无反应的敏感度分别为59%与62%,特异度95%。

核心结论

  • AI驱动的OCT地图状萎缩自动量化与全局视觉敏感度丧失范围强相关,与基于FAF手动标注的结果相当。
  • 作者认为这些发现证实了OCT来源地图状萎缩测量预期的功能相关性及其在监测地图状萎缩疾病进展中的临床效用。

研究设计与样本

  • 纳入50例年龄相关性黄斑变性继发地图状萎缩患者,每例一眼在中央8°半径区域内行缺陷映射微视野检查。
  • OCT图像使用基于AI的多类分类与分割模型自动分割地图状萎缩,FAF图像上的地图状萎缩由人工标注。
  • 在微视野检查采样的地形对应区域推导地图状萎缩范围,基于Spearman相关系数(ρ)分析结构与功能关系,并构建单点无反应的预测模型。

主要发现

  • 缺陷映射微视野检查漏检点比例与中央8°半径区域内OCT地图状萎缩百分比强相关(ρ=0.85)。
  • 缺陷映射微视野检查漏检点比例与中央8°半径区域内FAF地图状萎缩百分比强相关(ρ=0.89)。
  • 基于OCT与FAF地图状萎缩预测单个测试点无反应的模型在95%特异度下敏感度分别为59%与62%(p=0.310)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To examine the association between artificial intelligence (AI)-driven segmentation of geographic atrophy (GA) on optical coherence tomography (OCT) and visual sensitivity loss quantified by defect-mapping microperimetry, a testing strategy optimised to quantify the spatial extent of deep visual sensitivity losses. METHODS: 50 individuals with GA secondary to age-related macular degeneration underwent defect-mapping microperimetry testing within the central 8° radius region in one eye. GA on OCT was automatically segmented with an AI-based multiclass classification and segmentation model, and GA on fundus autofluorescence (FAF) images was manually annotated. Their extent in the topographically corresponding region sampled on microperimetry was derived, and structure-function relationships were examined based on Spearman correlation coefficients (ρ). The distance of each test location from the OCT-defined and FAF-defined GA margin was also derived and used in prediction models of non-response on defect-mapping microperimetry. RESULTS: There was a strong correlation between the proportion of locations missed on defect-mapping microperimetry and the corresponding percentage of the central 8° radius region with GA on OCT (ρ=0.85) and FAF (ρ=0.89). Prediction models for non-response at individual test locations using GA derived from OCT and FAF imaging had a sensitivity of 59% and 62% (p=0.310), respectively, at 95% specificity. CONCLUSIONS: AI-driven, automated quantification of GA on OCT showed a strong correlation with the global extent of visual sensitivity loss, comparable with those based on manual annotations on FAF imaging. These findings affirm the expected functional relevance of OCT-derived GA measurements and their clinical utility for monitoring disease progression in those with GA.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Merle DA, Guymer RH, Chia MA, et al. Mapping the impact: AI-driven quantification of geographic atrophy on OCT scans and its association with visual sensitivity loss. Br J Ophthalmol. 2025. PMID: 40490296. doi:10.1136/bjo-2024-326603

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。