文献速递小儿眼科与斜弱视

利用睫状肌麻痹验光与既往眼轴变化建立无近视儿童近视发生预测模型

Establishment of Myopia Occurrence Prediction Model in Children without Myopia Using Cycloplegic Refraction and Prior Axial Length Change.
PubMed 文献 · Ophthalmology · 2025-06-16

PURPOSE: Predicting myopia onset is critical for the identification of premyopia. This study aimed to develop and validate a myopia occurrence prediction model and further investigated potential premyopia criteria. DESIGN: Five-year prospective study.…

要点

  • 基线等效球镜度与既往眼轴变化对近视发生有较强预测价值。
  • 最终模型纳入既往1年眼轴变化、基线等效球镜度、性别及父母近视情况。
  • 模型区分度良好,1至4年预测受试者工作特征曲线下面积主队列0.879至0.941、验证队列0.877至0.928。

核心结论

  • 这项前瞻性研究结合睫状肌麻痹验光与既往眼轴变化建立并验证了近视预测模型,并建立了用于近视前期定义的潜在等效球镜度阈值。

研究设计与样本

  • 每次随访用Early Treatment Diabetic Retinopathy Study图表翻转E视标评估裸眼视力,用KR8800桌面式自动验光仪在1%环喷托酯滴眼3滴、每5分钟1滴完全睫状肌麻痹后行验光,用IOL Master 500非接触部分相干激光干涉测量眼轴。

主要发现

  • 基线等效球镜度与既往眼轴变化显示较强预测价值,使用既往2年变化仅带来极小改善,故最终模型纳入既往1年眼轴变化、基线等效球镜度、性别及父母近视情况。
  • 列线图校准良好、具有临床净获益与区分度,1至4年预测的受试者工作特征曲线下面积在主队列为0.879至0.941、在验证队列为0.877至0.928。
  • 校准图与决策曲线分析显示良好一致性(所有Brier评分<0.25)与临床价值。
  • 基于该模型建立了不同条件下的等效球镜度阈值,用于映射未来近视发生风险,模型已整合至开源在线风险计算器。

关键数值与推荐

  • 1至4年预测的受试者工作特征曲线下面积在主队列为0.879至0.941、在验证队列为0.877至0.928。
  • 所有Brier评分<0.25。
  • 基于模型建立了不同条件下的等效球镜度阈值以映射未来近视发生风险。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需要在不同人群中开展更大规模研究以验证这些发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Predicting myopia onset is critical for the identification of premyopia. This study aimed to develop and validate a myopia occurrence prediction model and further investigated potential premyopia criteria. DESIGN: Five-year prospective study. PARTICIPANTS: Four thousand four hundred thirty-seven children 6 to 9 years of age from 12 schools. METHODS: Five valid follow-up visits were completed from 2018 through 2023. At each visit, uncorrected visual acuity was evaluated using the Early Treatment Diabetic Retinopathy Study chart with tumbling E optotypes (Precision Vision). Cycloplegic autorefraction was performed with a desktop autorefractor (KR8800; Topcon Corp). Cycloplegia was induced with 3 drops of 1% cyclopentolate, instilled 5 minutes apart. Refraction measurements were obtained after complete cycloplegia, which was confirmed by the absence of light reflex and a dilated pupil of at least 6 mm in diameter. Axial length (AL) was measured using noncontact partial-coherence laser interferometry (IOL Master 500; Zeiss). MAIN OUTCOME MEASURES: Cycloplegic spherical equivalent refraction (SER) and AL. RESULTS: Baseline SER and prior AL change showed strong predictive value. Minimal improvement was found using prior 2-year changes, and hence the final model incorporated prior 1-year AL change, baseline SER, sex, and parents with myopia. The nomogram exhibited excellent calibration, clinical net benefit, and discrimination, with areas under the receiver operating characteristic curve of 0.879 to 0.941 (1- to 4-year prediction) in the primary cohort and 0.877 to 0.928 (1- to 4-year prediction) in the validation cohort. Calibration plots and decision curve analysis showed good consistency (all Brier scores < 0.25) and clinical value. Based on the model, SER thresholds under various conditions were established to map the risk of myopia occurrence in the future. The model was integrated into an open-source online risk calculator. CONCLUSIONS: This prospective study combined cycloplegic refraction with prior AL change to develop and validate a myopia prediction model, establishing potential SER thresholds for premyopia definition. Larger-scale studies across diverse populations are warranted to validate these findings. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Xu S, Ruan Z, Wang Y, et al. Establishment of Myopia Occurrence Prediction Model in Children without Myopia Using Cycloplegic Refraction and Prior Axial Length Change. Ophthalmology. 2025. PMID: 40516576. doi:10.1016/j.ophtha.2025.06.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。