文献速递白内障与屈光手术

两款面向微型单眼视设计的新型扩展焦深人工晶状体:一项前瞻性随机对照试验

Two novel extended depth-of-focus intraocular lenses targeted for mini-monovision: A prospective randomized controlled trial.
PubMed 文献 · Am J Ophthalmol · 2025-04-24

单中心前瞻性随机对照试验纳入31例(62眼)双侧白内障手术患者,随机植入Acunex Vario或AcrySof IQ Vivity扩展焦深人工晶状体并采用微型单眼视方案。术后3个月两组双眼裸眼远、中、近视力及对比敏感度、阅读速度、光学副作用均无统计学显著差异,Vario组离焦曲线范围更大。

要点

  • 术后3个月两组双眼裸眼远、中、近视力在协变量校正后均无统计学显著差异。
  • Vario组离焦曲线连续范围较Vivity组更大。
  • 两组患者满意度、脱镜率、对比敏感度、阅读速度及光学副作用均无统计学显著差异。

核心结论

  • 双侧植入Acunex Vario与AcrySof IQ Vivity人工晶状体并采用微型单眼视方案,在双眼视力结局、对比敏感度、光学副作用和阅读速度方面结果相当。
  • Vario组显示出更大的连续离焦范围。

研究设计与样本

  • 单中心前瞻性随机对照试验,在荷兰马斯特里赫特大学医学中心+大学眼科诊所开展。
  • 接受双侧白内障手术的患者随机分配植入Acunex Vario人工晶状体(Teleon Surgical B.V.,荷兰Spankeren)或AcrySof IQ Vivity人工晶状体(Alcon Laboratories Inc.,美国得克萨斯州沃思堡),两组均采用微型单眼视方案。
  • 共纳入31例受试者(62眼),Vario组16例,Vivity组15例。
  • 主要结局为66 cm处裸眼中视力(UIVA);次要结局包括裸眼远视力(UDVA)、裸眼近视力(UNVA)、离焦曲线、阅读速度、对比敏感度、脱镜率和视觉质量。

主要发现

  • 术后3个月,协变量校正后两组双眼视力无统计学显著差异。
  • 双眼UIVA:Vario组0.04±0.11 logMAR vs Vivity组0.15±0.11 logMAR(校正P=0.264)。
  • 双眼UDVA:Vario组0.00±0.14 logMAR vs Vivity组0.08±0.10 logMAR(校正P=0.753)。
  • 双眼UNVA:Vario组0.22±0.17 logMAR vs Vivity组0.31±0.14 logMAR(校正P=0.235)。
  • Vario组离焦范围更大;两组患者满意度和脱镜率无显著差异,对比敏感度和阅读速度相当,光学副作用无统计学显著差异。

关键数值与推荐

  • 主要结局为66 cm处裸眼中视力(UIVA)。
  • 术后3个月双眼UIVA:Vario组0.04±0.11 logMAR vs Vivity组0.15±0.11 logMAR(校正P=0.264)。
  • 术后3个月双眼UDVA:Vario组0.00±0.14 logMAR vs Vivity组0.08±0.10 logMAR(校正P=0.753)。
  • 术后3个月双眼UNVA:Vario组0.22±0.17 logMAR vs Vivity组0.31±0.14 logMAR(校正P=0.235)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the visual outcomes of two extended depth-of-focus (EDOF) intraocular lenses (IOLs). DESIGN: Single-center prospective randomized controlled trial. METHODS: Patients undergoing bilateral cataract surgery were randomly assigned to receive either the Acunex Vario IOL (Teleon Surgical B.V., Spankeren, The Netherlands) or the AcrySof IQ Vivity IOL (Alcon Laboratories Inc., Fort Worth, United States of America); both Vario-group and Vivity-group were targeted for mini-monovision. The primary outcome was the uncorrected intermediate visual acuity (UIVA, measured at 66cm). Secondary outcome parameters were uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), defocus curves, reading speed, contrast sensitivity, spectacle independence and quality of vision. SETTING: University Eye Clinic, Maastricht University Medical Center+, the Netherlands. RESULTS: A total of 31 subjects (62 eyes) were included, 16 patients were enrolled into the Vario-group and 15 patients into the Vivity-group. At three months postoperatively, no statistically significant differences were found for the binocular visual acuities between the groups after adjustment for covariates. The mean and standard deviation for the binocular UIVA was 0.04±0.11 and 0.15±0.11 logMAR (adjusted-P=0.264) for the Vario-group and Vivity-group, respectively. The binocular UDVA was 0.00±0.14 and 0.08±0.10 logMAR (adjusted-P=0.753), and UNVA was 0.22±0.17 and 0.31±0.14 logMAR (adjusted-P=0.235), for both groups, respectively. While the Vario-group had a larger range of defocus, no significant differences were found for patient satisfaction and spectacle independence. Contrast sensitivity and reading speed were comparable, and there were no statistically significant differences in optical side effects between the groups. CONCLUSION: Bilateral implantation of the Acunex Vario IOL and the AcrySof IQ Vivity IOL targeted for mini-monovision had comparable results for binocular visual acuity outcomes, contrast sensitivity, optical side effects, and reading speed. The Vario-group showed a larger continuous range of defocus.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Wanten JC, Bauer NJC, Berendschot TTJM, et al. Two novel extended depth-of-focus intraocular lenses targeted for mini-monovision: A prospective randomized controlled trial. Am J Ophthalmol. 2025. PMID: 40287004. doi:10.1016/j.ajo.2025.04.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。