文献速递眼底病与葡萄膜炎

应用宏基因组长读长测序诊断疱疹性葡萄膜炎

Application of Metagenomic Long-Read Sequencing for the Diagnosis of Herpetic Uveitis.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2025-01-01

本研究纳入43例经房水多重聚合酶链反应(mPCR)筛查眼内疱疹病毒的葡萄膜炎患者,比较纳米孔宏基因组分析(NMA)与mPCR的检测性能。Flongle流动池NMA对mPCR阳性样本的检出率为60.0%(12/20),改用MinION流动池后总灵敏度达75.0%(15/20),所有长读长测序检出的病毒均与mPCR诊断一致,mPCR阴性样本均未检出疱疹病毒DNA。

要点

  • Flongle流动池NMA对mPCR阳性样本的疱疹病毒检出率为60.0%(12/20)。
  • 改用MinION流动池后,8例初筛未检出样本中3例检出病毒DNA,总灵敏度75.0%(15/20)。
  • 长读长测序检出的病毒均与mPCR诊断一致,mPCR阴性样本均未检出疱疹病毒DNA。

核心结论

  • 对于病原性疱疹病毒DNA片段的检测,NMA显示出合理的灵敏度和高特异性。
  • 本研究凸显了纳米孔测序在推动葡萄膜炎诊断进一步进展方面的潜力。

研究设计与样本

  • 本研究纳入43例葡萄膜炎患者,这些患者均已通过房水样本mPCR筛查眼内疱疹病毒感染。
  • mPCR后保存的房水样本经全基因组扩增、长读长测序,并在Oxford Nanopore MinION平台上使用Flongle流动池进行系统发育微生物组成分析。
  • 对mPCR阳性而Flongle流动池阴性的样本,使用MinION流动池进行额外长读长测序以获取更多序列数据。
  • 将NMA检测疱疹病毒的灵敏度与特异性同mPCR阳性及阴性对照进行比较。

主要发现

  • 使用Flongle流动池的NMA在mPCR阳性者中检出病原病毒的比例为60.0%(12/20)。
  • 使用MinION流动池进一步分析后,8例初筛未检出样本中3例成功识别出病毒DNA片段,合计灵敏度为75.0%(15/20)。
  • 长读长测序检出的所有病毒均与mPCR诊断的病毒一致。
  • mPCR检测阴性的样本中,长读长测序均未发现疱疹病毒DNA。

关键数值与推荐

  • Flongle流动池NMA对mPCR阳性样本的检出率为60.0%(12/20)。
  • Flongle联合MinION流动池NMA的总灵敏度为75.0%(15/20)。
  • mPCR阴性样本经长读长测序均未检出疱疹病毒DNA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the sensitivity and specificity of herpes virus detection by nanopore metagenomic analysis (NMA) compared with multiplex polymerase chain reaction (mPCR)-positive and -negative controls. METHODS: This study included 43 patients with uveitis who had been screened for intraocular herpes virus infection using mPCR from aqueous humor samples. Aqueous humor samples stored after mPCR were subjected to whole-genome amplification, long-read sequencing, and analysis of the phylogenetic microorganism composition using a Flongle flow cell on the Oxford Nanopore MinION platform. For samples that tested positive with mPCR and negative with the Flongle flow cell, additional long-read sequencing was performed using a MinION flow cell, which enabled acquisition of more sequence data. The sensitivity and specificity of herpes virus detection by NMA were compared with the mPCR-positive and -negative controls. RESULTS: NMA using a Flongle flow cell detected the pathogenic virus in 60.0% of those who tested positive by mPCR (12/20). Further analysis using the MinION flow cell successfully identified viral DNA fragments in three out of the eight initially undetected samples, yielding a collective sensitivity of 75.0% (15/20). All of the virus detected with the long-read sequencing were identical to those diagnosed by mPCR testing, and none of the samples that tested negative by mPCR revealed herpes viral DNA with the use of long-read sequencing. CONCLUSIONS: For the detection of etiologic herpes virus DNA fragments, NMA revealed a reasonable sensitivity and high specificity. Our study highlights the potential of nanopore sequencing to facilitate further advances in uveitis diagnosis.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Koyanagi Y, Sajiki AF, Yuki K, et al. Application of Metagenomic Long-Read Sequencing for the Diagnosis of Herpetic Uveitis. Invest Ophthalmol Vis Sci. 2025. PMID: 40244604. doi:10.1167/iovs.66.4.50

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。