文献速递角膜与眼表疾病小儿眼科与斜弱视

配戴不同后光学区直径角膜塑形镜控制近视时角膜屈光力变化的新型模型

A Novel Model for Cornea Power Shift in Eyes Wearing Orthokeratology Lenses With Different Back Optic Zone Diameters for Myopia Control.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2025-01-01

一项前瞻性自身对照研究纳入33例受试者,随机配戴后光学区直径5 mm或6 mm的角膜塑形镜,使用河岸模型拟合角膜屈光力变化曲线。5 mm组眼轴增长显著慢于6 mm组,且颞侧位置偏移较小,位置偏移与眼轴增长显著相关。

要点

  • 配戴5 mm后光学区直径镜片眼轴增长0.19±0.15 mm,显著慢于6 mm组的0.26±0.15 mm(P<0.01)。
  • 5 mm组治疗区面积更小(6.76±2.21 vs 8.07±2.01 mm²,P<0.01)。
  • 仅位置偏移与眼轴增长显著相关(P=0.01)。

核心结论

  • 配戴后光学区直径5 mm镜片的眼眼轴增长显著慢于配戴6 mm镜片的眼,此差异可能归因于颞侧位置偏移较小。

研究设计与样本

  • 前瞻性自身对照研究,于2022年6月至2023年12月开展,共纳入33例受试者,每例随机一眼配戴后光学区直径5 mm或6 mm的角膜塑形镜。
  • 在基线、配戴后6个月和12个月进行角膜地形图检查,并在6个月和12个月测量眼轴长度以计算眼轴增长。
  • 采用河岸模型拟合角膜屈光力变化曲线,参数描述振幅、位置偏移、斜率和基底;使用线性混合模型评估眼轴增长与模型参数的关联。

主要发现

  • 配戴5 mm镜片眼眼轴增长0.19±0.15 mm,配戴6 mm镜片眼眼轴增长0.26±0.15 mm,5 mm组显著更慢(P<0.01)。
  • 5 mm组治疗区面积为6.76±2.21 mm²,6 mm组为8.07±2.01 mm²,5 mm组更小(P<0.01)。
  • 在360度平均的相对角膜屈光力变化曲线中,5 mm组振幅为4.70±1.05 D,6 mm组为4.33±0.99 D(P=0.04);5 mm组位置偏移为1.97±0.32 mm,6 mm组为2.11±0.27 mm(P<0.01)。
  • 在八个不同子午线计算的相对角膜屈光力变化曲线中,各组参数均发现强的子午线调制;组间参数显著差异仅见于颞侧(P<0.01)。
  • 多元回归显示仅位置偏移与眼轴增长显著相关(P=0.01)。

关键数值与推荐

  • 后光学区直径5 mm组眼轴增长0.19±0.15 mm,6 mm组0.26±0.15 mm(P<0.01)。
  • 后光学区直径5 mm组治疗区面积6.76±2.21 mm²,6 mm组8.07±2.01 mm²(P<0.01)。
  • 360度平均相对角膜屈光力变化曲线振幅:5 mm组4.70±1.05 D,6 mm组4.33±0.99 D(P=0.04)。
  • 360度平均相对角膜屈光力变化曲线位置偏移:5 mm组1.97±0.32 mm,6 mm组2.11±0.27 mm(P<0.01)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to quantify the corneal power changes after wearing orthokeratology lenses of different back optic zone diameters (BOZDs) and to propose a novel 4-parameter model capable of revealing the associations between each parameter and axial length growth (ALG). METHODS: A prospective self-controlled study was conducted between June 2022 and December 2023. One eye in each subject (N = 33) was randomly assigned to wear a lens with a BOZD of either 5 mm (5 oz) or 6 mm (6 oz). Axial lengths were measured at 6 and 12 months and ALG was calculated from those measurements. Corneal topography obtained at baseline, 6 months, and 12 months after lens-wearing was analyzed, and the central flatten region is considered as the treatment zone (TZ). The power change profile was fitted with a riverbank model with parameters describing the amplitude, location shift, slope, and base. A linear mixed model was used to evaluate the association between ALG and model parameters. RESULTS: ALG was significantly slower in eyes wearing 5 oz lenses (0.19 ± 0.15 vs. 0.26 ± 0.15 mm, P < 0.01). TZ sizes were smaller in the 5 oz group (6.76 ± 2.21 vs. 8.07 ± 2.01 mm2, P < 0.01). For relative corneal refractive powers shift (RCRPS) profiles averaged across 360 degrees, greater amplitudes (4.70 ± 1.05 vs. 4.33 ± 0.99 diopter [D], P = 0.04) and smaller location shifts (1.97 ± 0.32 vs. 2.11 ± 0.27 mm, P < 0.01) were found in the 5 oz group. For RCRPS profiles calculated in eight different meridians, strong meridional modulations were found in the parameters in each group. Moreover, significant inter-group parameter differences (P < 0.01) were only found on the temporal side. Multiple regression showed that only location shift was significantly associated with ALG (P = 0.01). CONCLUSIONS: Eyes wearing a 5 oz lens had significantly slower ALG, compared with the eyes wearing 6 oz lens. Such difference may be attributed to the smaller location shift on the temporal side.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Wang T, Chen X, Li M, et al. A Novel Model for Cornea Power Shift in Eyes Wearing Orthokeratology Lenses With Different Back Optic Zone Diameters for Myopia Control. Invest Ophthalmol Vis Sci. 2025. PMID: 40072445. doi:10.1167/iovs.66.3.29