五种现代环曲面人工晶状体计算公式的准确性比较
该回顾性比较分析纳入146例(146眼)伴散光的白内障患者,比较Barrett、EVO、Naeser/Savini联合Hoffer QST、Kane及Abulafia-Koch联合Hill RBF五种环曲面人工晶状体计算公式的预测准确性。总体平均绝对预测误差无显著差异(P > .05),EVO公式在顺规散光亚组中表现更优。
要点
- 总体队列中五种公式的平均绝对预测误差无显著差异(P > .05)。
- 预测误差≤±0.50 D的眼占比以EVO最高(71.92%)。
- 在逆规散光亚组中,EVO、Abulafia-Koch联合Hill RBF及Naeser/Savini联合Hoffer QST的平均绝对预测误差显著低于Barrett(P < .05)。
核心结论
- 五种环曲面人工晶状体计算公式总体准确性均良好,特定亚组存在轻微差异,EVO公式在逆规散光中精度更优。
研究设计与样本
- 回顾性比较分析,纳入146例伴散光的白内障患者共146眼,均行环曲面人工晶状体植入。
- 使用Lenstar LS900获取生物测量数据,并按每位术者应用个性化手术源性散光值。
- 评估指标包括平均绝对预测误差、质心误差及预测误差在±0.50 D和±0.75 D以内的眼占比。
- 对顺规散光、逆规散光和斜向散光进行亚组分析,采用非参数检验和多变量检验评估统计学显著性。
- 研究地点为韩国首尔Eunpyeong St. Mary's Hospital。
主要发现
- 总体队列中五种公式的平均绝对预测误差无显著差异(P > .05)。
- 预测误差≤±0.50 D的眼占比:EVO为71.92%,Kane和Abulafia-Koch联合Hill RBF为70.55%,Naeser/Savini联合Hoffer QST为69.18%,Barrett为67.12%。
- 在逆规散光病例中,EVO、Abulafia-Koch联合Hill RBF和Naeser/Savini联合Hoffer QST的平均绝对预测误差显著低于Barrett(P < .05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the clinical accuracy of 5 modern toric intraocular lens (IOL) calculation formulas-Barrett, EVO, Naeser/Savini combined with Hoffer QST, Kane, and Abulafia-Koch combined with Hill RBF-in predicting postoperative refractive outcomes in cataract patients with astigmatism. DESIGN: Retrospective, comparative analysis of IOL formula accuracy. SUBJECTS: One hundred forty-six eyes from 146 cataract patients with toric IOL implantation. METHODS: Biometric measurements were obtained using the Lenstar LS900, with personalized surgically induced astigmatism values applied for each surgeon. Postoperative outcomes, including mean absolute prediction error (MAE), centroid error, and the proportion of eyes within a prediction error of ±0.50 D and ±0.75 D, were evaluated. Subgroup analyses were performed for with-the-rule (WTR), against-the-rule (ATR), and oblique astigmatism. Statistical significance was assessed using non-parametric and multivariate tests. SETTING: Eunpyeong St. Mary's Hospital, Seoul, Republic of Korea. RESULTS: No significant differences in MAE were observed among the formulas in the overall cohort (P > .05). The proportion of eyes with a prediction error ≤ ±0.50 D was highest for EVO (71.92%), followed by Kane and Abulafia-Koch with Hill RBF (70.55%), Naeser/Savini with Hoffer QST (69.18%), and Barrett (67.12%). Among ATR cases, EVO, Abulafia-Koch with Hill RBF, and Naeser/Savini with Hoffer QST demonstrated statistically lower MAEs compared to Barrett (P < .05). CONCLUSION: All 5 toric IOL calculation formulas demonstrated excellent overall accuracy, with slight variations observed in specific subgroups. The EVO formula showed superior precision in ATR astigmatism. These findings provide real-world insights to enhance refractive outcomes and optimize formula selection in toric IOL surgery.
引用
- Yang S, Han H, Lee HS, et al. Comparative Accuracy Of Five Modern Toric Intraocular Lens Formulas. Am J Ophthalmol. 2025. PMID: 40010422. doi:10.1016/j.ajo.2025.02.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。