文献速递白内障与屈光手术青光眼

极短眼轴眼的白内障手术:300只眼的形态学、合并症与结局

Cataract surgery in the extremely small eye: morphology, comorbidities and outcomes in 300 eyes.
PubMed 文献 · Br J Ophthalmol · 2025-07-22

该回顾性队列研究纳入2009年1月至2023年10月间191例患者300只极短眼轴眼,均植入屈光度>30D的高屈光度人工晶状体。术后矫正远视力(CDVA)较术前轻度改善(0.28±0.31 logMAR,p=0.02),术后裸眼远视力(UDVA)与术前CDVA无显著差异(0.47±0.38 logMAR vs 0.34±0.39 logMAR,p=0.47);作者结论为晶状体手术安全、改善前房情况但精度欠佳,纳米眼亚型结局较差。

要点

  • 极短眼轴眼植入>30D人工晶状体后,术后CDVA较术前轻度改善(0.28±0.31 logMAR,p=0.02)。
  • 术后UDVA与术前CDVA无显著差异(0.47±0.38 logMAR vs 0.34±0.39 logMAR,p=0.47)。
  • 纳米眼亚型在全部亚型中结局较差。

核心结论

  • 晶状体手术在极短眼轴眼中安全并改善前房情况,但精度欠佳。
  • 全部亚型中纳米眼结局较差。
  • 术后CDVA较术前CDVA仅轻度改善,术后UDVA与术前CDVA接近,手术因而提供脱镜并带来良好患者满意度。

研究设计与样本

  • 回顾性队列研究,时间范围为2009年1月至2023年10月。
  • 纳入191例患者300只极短眼轴眼,均因极短眼轴需植入屈光度>30D的高屈光度人工晶状体。
  • 按形态分为纳米眼(N)、相对前段小眼球(RAM)、高度远视(HH)及低/中度远视(MH)四类。
  • 考察合并症、术中及术后并发症、术前术后屈光及视力结局。

主要发现

  • 术前等效球镜度(SE)平均+6±2.85 D,眼轴平均20.68±0.92 mm。
  • MH、HH、N、RAM分别占19.3%、45.3%、22.7%、12.7%。
  • 合并症包括弱视(14.7%)、既往斜视手术(7.3%)、青光眼(12.7%)及既往虹膜切开(9.4%)。
  • 术后SE为-0.42±1.56 D。
  • 术前CDVA与术后UDVA无显著差异(0.34±0.39 logMAR vs 0.47±0.38 logMAR,p=0.47),术后CDVA轻度改善(0.28±0.31 logMAR,p=0.02);窄前房角显著缓解,后囊膜破裂率为3%。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: Data on morphological characteristics and outcomes of extremely short eyes undergoing cataract surgery is sparse. Thus, an in-depth characterisation of eyes implanted with a high-power intraocular lens (IOL) (>30 dioptres) was performed. METHODS: In this retrospective cohort study from January 2009 to October 2023, 300 eyes of 191 patients undergoing cataract surgery with extremely short axial length requiring the implantation of a high power IOL>30D were included. Eyes were categorised into the morphologies of nanophthalmos (N), relative anterior microphthalmos (RAM) and high or low/moderate hyperopia (HH and MH). Comorbidities, intraoperative and postoperative complications, preoperative and postoperative refraction and visual outcomes were investigated. RESULTS: Mean preoperative spherical equivalent (SE) was +6±2.85 D. The mean axial length was 20.68±0.92 mm. 19.3%, 45.3%, 22.7% and 12.7% of the studied eyes were categorised as MH, HH, N and RAM, respectively. Amblyopia (14.7%), previous strabismus surgery (7.3%), glaucoma (12.7%) and previous iridotomy (9.4%) were prevalent. Postoperative SE was -0.42±1.56 D. Preoperative Corrected Distance Visual Acuity (CDVA) and postoperative Uncorrected Distance Visual Acuity (UDVA) were not significantly different (0.34±0.39 Logarithm of the Minimum Angle of Resolution (logMAR) vs 0.47±0.38 logMAR, respectively, p=0.47), postoperative CDVA was slightly improved (0.28±0.31 logMAR, p=0.02). The narrow anterior chamber angle was significantly alleviated, posterior capsule rupture rates (3%) were within previously reported ranges. CONCLUSIONS: Lens surgery is safe, improves the anterior chamber situation but is rather imprecise in extremely short eyes. Of all subtypes, nanophthalmic eyes showed compromised outcomes. Postoperative CDVA is only slightly improved to preoperative CDVA, while postoperative UDVA closely resembles preoperative CDVA. Surgery thus provides spectacle independence leading to good patient satisfaction.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Hammer M, Teich L, Friedrich M, et al. Cataract surgery in the extremely small eye: morphology, comorbidities and outcomes in 300 eyes. Br J Ophthalmol. 2025. PMID: 40015941. doi:10.1136/bjo-2024-326998

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。