肺功能作为青光眼生物标志物:英国生物样本库研究
这项横断面研究纳入英国生物样本库85,369名有基线肺功能测量的参与者,发现用力肺活量、第1秒用力呼气容积及FEV1/FVC比值最低四分位组与最高四分位组相比青光眼风险更高,肺功能受损与青光眼风险升高相关;孟德尔随机化分析未提示因果关系。
要点
- FVC、FEV1、FEV1/FVC最低四分位组与最高四分位组相比青光眼风险升高,趋势P<0.001。
- 肺功能受损(FEV1<80%预计值或FEV1/FVC<0.7)与青光眼风险升高相关。
- 孟德尔随机化分析未提示肺功能与青光眼之间存在因果关系。
核心结论
- 较低的FVC、FEV1、FEV1/FVC及肺功能受损是青光眼风险的潜在生物标志物。
- 这些发现可能有助于青光眼管理的临床策略,尤其是对肺功能受损的个体。
研究设计与样本
- 横断面研究,纳入英国生物样本库85,369名基线有肺功能测量的参与者。
- 采用多因素逻辑回归和线性回归检验肺功能参数与青光眼及相关特征的关联。
- 使用大型遗传数据集的汇总统计进行两样本孟德尔随机化分析。
主要发现
- FVC最低四分位组与最高四分位组相比青光眼OR为1.51(95%CI 1.31-1.74;P=7.6×10⁻⁸)。
- FEV1最低四分位组与最高四分位组相比青光眼OR为1.58(95%CI 1.37-1.81;P=4.7×10⁻¹⁰)。
- FEV1/FVC最低四分位组与最高四分位组相比青光眼OR为1.20(95%CI 1.08-1.34;P=0.002)。
- 肺功能受损者中,FEV1<80%全球肺功能倡议预计值者青光眼OR为1.22(95%CI 1.11-1.33;P=1.2×10⁻⁵),FEV1/FVC<0.7者OR为1.13(95%CI 1.03-1.24;P=0.01)。
- 较低的肺功能与较低的眼内压、较薄的黄斑视网膜神经纤维层厚度及较薄的神经节细胞-内丛状层厚度相关;未观察到青光眼遗传风险与肺功能之间的交互作用;孟德尔随机化分析未提示因果关系。
关键数值与推荐
- FVC、FEV1、FEV1/FVC最低四分位组与最高四分位组相比青光眼风险升高,各参数趋势P<0.001。
- 肺功能受损定义:FEV1<80%全球肺功能倡议预计值(OR 1.22,95%CI 1.11-1.33;P=1.2×10⁻⁵);FEV1/FVC<0.7(OR 1.13,95%CI 1.03-1.24;P=0.01)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the associations of lung function with glaucoma and related traits, explore the interactions between glaucoma genetic risk and lung function, and assess the causal relationships using Mendelian randomization (MR). METHODS: This cross-sectional study involved 85,369 participants with lung function measurements at baseline from the UK Biobank. Associations between lung function parameters and glaucoma and related traits were tested by multivariable logistic and linear regression. Two-sample MR analyses were conducted using summary statistics from large genetic datasets. RESULTS: Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), and FEV1/FVC ratio were inversely associated with glaucoma, with the lowest quartiles conferring odds ratios (ORs) of 1.51 (95% confidence interval [CI], 1.31-1.74; P = 7.6 × 10-8), 1.58 (95% CI, 1.37-1.81; P = 4.7 × 10-10) and 1.20 (95% CI, 1.08-1.34; P = 0.002), respectively, compared with the highest quartiles (P trends < 0.001 observed for each). Similar associations were found for impaired lung function (FEV1 <80% Global Lung Initiative predicted FEV1: OR, 1.22, 95% CI, 1.11-1.33; P = 1.2 × 10-5; FEV1/FVC <0.7: OR, 1.13, 95% CI, 1.03-1.24; P = 0.01). Lower lung function was associated with lower intraocular pressure (IOP), thinner macular retinal nerve fiber layer thickness, and thinner ganglion cell-inner plexiform layer thickness. No interactions were observed between glaucoma genetic risk and lung function. MR analyses did not suggest causal relationships. CONCLUSIONS: Lower FVC, FEV1, FEV1/FVC, and impaired lung function are potential biomarkers for glaucoma risk. These findings may facilitate clinical strategies for glaucoma management, particularly for individuals with impaired lung function.
引用
- Yu J, Zhang Y, Kam KW, et al. Lung Function as a Biomarker for Glaucoma: The UK Biobank Study. Invest Ophthalmol Vis Sci. 2025. PMID: 39964321. doi:10.1167/iovs.66.2.48
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。