文献速递眼底病与葡萄膜炎

针对中度年龄相关性黄斑变性局灶性病变的靶向微视野网格:PINNACLE研究第7号报告

Targeted Microperimetry Grids for Focal Lesions in Intermediate AMD: PINNACLE Study Report 7.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2025-01-01

多中心前瞻性PINNACLE研究纳入395例55至90岁中度年龄相关性黄斑变性患者,在12个国际中心每4至12个月进行OCT和微视野检查,随访3年。深度学习算法检测局灶性病变并引导5点靶向微视野检查,最终分析93眼、83例患者、605个靶向网格、235个局灶性病变。靶向网格测得的敏感度与标准网格插值敏感度的Pearson相关系数为0.76,但标准网格插值可能出错,尤其在EZ/IZ丢失伴高透射和视网膜下液的病变中央区域。

要点

  • 靶向微视野网格可改善对中度年龄相关性黄斑变性局灶性视网膜改变如何影响视功能的检测和理解。
  • 标准网格插值误差随与最近测量点距离增加而增大(斜率=2.20 dB/度,95%CI=1.52至2.87)。
  • 插值误差与视网膜敏感度呈显著负相关,敏感度低的区域误差最高。

核心结论

  • 靶向网格改善了对中度年龄相关性黄斑变性患者局灶性视网膜改变如何影响视功能的检测和理解,支持治疗干预的开发。

研究设计与样本

  • 多中心前瞻性PINNACLE研究纳入12个国际中心395例55至90岁中度年龄相关性黄斑变性患者。
  • 参与者每4至12个月接受包括OCT和微视野的影像检查,随访3年。
  • 深度学习算法检测OCT图像中的局灶性病变及变化,包括玻璃膜疣消退、EZ/IZ丢失伴高透射和视网膜下液,并引导针对病变位置的5点微视野检查。
  • 数据采用线性混合模型分析,估计5点局灶网格测得的视网膜敏感度与24点标准网格插值敏感度之间的差异。
  • 最终分析纳入83例患者的93眼,评估235个局灶性病变的605个5点靶向网格和标准网格。

主要发现

  • 局灶实测敏感度与插值敏感度的Pearson相关系数为0.76。
  • 标准网格插值可能出错,尤其在以EZ/IZ丢失伴高透射和视网膜下液为特征的病变中央区域。
  • 插值误差随与最近测量点距离增加而增大(斜率=2.20 dB/度,95%CI=1.52至2.87)。
  • 插值误差与视网膜敏感度呈显著负相关,敏感度低的区域误差最高。
  • 病变大小显著影响EZ/IZ丢失伴高透射的插值误差(斜率=-19.41 dB/mm²,95%CI=-29.63至-9.18)。

关键数值与推荐

  • 5点靶向网格实测敏感度与24点标准网格插值敏感度的Pearson相关系数为0.76。
  • 插值误差随与最近测量点距离变化的斜率为2.20 dB/度(95%CI=1.52至2.87)。
  • EZ/IZ丢失伴高透射的插值误差随病变大小变化的斜率为-19.41 dB/mm²(95%CI=-29.63至-9.18)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to evaluate the feasibility and utility of optical coherence tomography (OCT)-based, targeted microperimetry grids in assessing focal lesions in intermediate age-related macular degeneration (iAMD). METHODS: The multicenter, prospective PINNACLE study enrolled 395 patients with iAMD aged 55 to 90 years across 12 international sites. Participants underwent imaging, including OCT and microperimetry, every 4 to 12 months over 3 years. Deep learning algorithms detected focal lesions and changes in OCT images, including drusen regression, EZ/IZ loss with hypertransmission, and subretinal fluid, guiding 5-point microperimetry targeted to lesion locations. Data were analyzed using linear mixed models to estimate differences between retinal sensitivity measured by the 5-point focal grids and sensitivity interpolated from the 24-point standard grids. RESULTS: The final analysis included 93 eyes from 83 patients, assessing 605 of the 5-point targeted grids and standard grids across 235 focal lesions. The Pearson correlation between focally measured sensitivity and interpolated sensitivity was 0.76. However, interpolation from the standard grid could be erroneous, especially in central regions of lesions characterized by EZ/IZ loss with hypertransmission and subretinal fluid. Interpolation errors increased with distance to the nearest measurement point (slope = 2.20 dB per degree, 95% confidence interval [CI] = 1.52 to 2.87). A significant negative relationship was found between interpolation errors and retinal sensitivity, with the highest errors in areas of low sensitivity. Lesion size significantly impacted interpolation errors for EZ/IZ loss with hypertransmission (slope = -19.41 dB/mm², 95% CI = -29.63 to -9.18). CONCLUSIONS: Targeted grids improved the detection and understanding of how focal retinal changes affect visual function in patients with iAMD, supporting the development of therapeutic interventions.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Futterknecht S, Anders P, Mai J, et al. Targeted Microperimetry Grids for Focal Lesions in Intermediate AMD: PINNACLE Study Report 7. Invest Ophthalmol Vis Sci. 2025. PMID: 39903180. doi:10.1167/iovs.66.2.6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。