一种用于长眼轴高度近视眼黄斑操作的新型手术技术
作者针对眼轴延长的超高度近视眼开发了一种新型手术技术,通过定位锯齿缘后更靠后置入穿刺套管,使常规镊子能够到达黄斑。在未灌注平衡盐溶液下行部分玻璃体切除以降低眼压,经巩膜压迫观察周边视网膜并标记后置入第三穿刺套管。结果可通过后置套管用常规镊子安全完成内界膜剥离等操作。
要点
- 定位锯齿缘并经巩膜压迫确认后,将第三穿刺套管更靠后置入以缩短至黄斑距离。
- 先置入两个端口,在不灌注平衡盐溶液下行部分玻璃体切除以降低眼压。
- 经后置套管可用常规镊子安全完成内界膜剥离等黄斑操作,无需专用设备。
核心结论
- 该技术为高度近视眼因眼轴延长在玻璃体视网膜手术中带来的挑战提供了解决方案。
- 通过更靠后置入穿刺套管,术者可增强对黄斑的可及性,且无需专用设备或复杂操作。
研究设计与样本
- 原文为手术技术描述,作者开发了针对眼轴延长的超高度近视眼的新型手术技术。
主要发现
- 先置入两个端口并在不灌注平衡盐溶液下行部分玻璃体切除以降低眼压。
- 用镊子经巩膜压迫观察到定位至锯齿缘的周边视网膜,精确标记该区域后置入第三穿刺套管并在术中确认其位置与放置。
- 经后置套管用常规镊子安全完成包括内界膜剥离在内的手术操作。
临床怎么用
- 作者描述的技术为高度近视眼眼轴延长时玻璃体视网膜手术提供解决思路,通过更靠后置入穿刺套管增强黄斑可及性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The authors developed a novel surgical technique tailored for highly myopic eyes characterized by extended axial lengths. Myopic eyes are prone to macular complications including macular schisis, full-thickness macular holes, and retinal detachment, which can cause severe vision loss. A pars plana vitrectomy is necessary in these cases. However, because of the considerable distance between the posterior pole and the cannula, regular forceps cannot reach the macula in some cases. To overcome this, the authors inserted a trocar more posteriorly after localizing the ora serrata. METHODS: First, the authors placed two ports and performed partial vitrectomy without the infusion of balanced salt solution to reduce the intraocular pressure. Subsequently, the authors observed the peripheral retina localized to the ora serrata by scleral indentation using forceps. After the precise marking of the area, a third trocar was inserted and its position and placement confirmed intraoperatively. RESULTS: Surgical maneuvers including a removal of the internal limiting membrane were safely performed using regular forceps through the posteriorly located cannula. CONCLUSION: The described technique offers a solution to the challenges posed by the extended axial lengths of highly myopic eyes during vitreoretinal surgery. By inserting the trocar more posteriorly, surgeons can enhance accessibility to the macula without requiring specialized equipment or extensive maneuvers.
引用
- Baba T, Nizawa T, Iwase T, et al. A Novel Surgical Technique for Macular Manipulation in Highly Myopic Eyes With Long Axial Length. Retina. 2025. PMID: 39964830. doi:10.1097/IAE.0000000000004195
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。