重硅油(Oxane HD与Densiron 68)在复杂原发性孔源性视网膜脱离中的解剖与功能结局
这项回顾性单中心非随机研究纳入82眼(82例)原发性黄斑未累及孔源性视网膜脱离伴下方增生性玻璃体视网膜病变,分别使用Oxane HD(45眼)或Densiron 68(37眼)重硅油填充,12个月随访显示两组初次和最终手术成功率无显著差异,Densiron 68组最终logMAR增益优于Oxane HD组(P=0.027),并发症发生率相似(P>0.05)。作者认为重硅油可能是有益的替代选择。
要点
- Oxane HD组初次和最终成功率分别为66.6%和75.7%,Densiron 68组分别为75.6%和81%,差异无统计学意义。
- 最终logMAR增益Oxane HD组为0.36±0.51(中位数0.2),Densiron 68组为0.57±0.58(中位数0.5),P=0.027。
- 两组并发症发生率相似(P>0.05),作者认为重硅油可能是有益的替代选择。
核心结论
- 作者认为重硅油可能是适合的原发性复杂孔源性视网膜脱离患者的一种有效替代选择,显示出高解剖成功率和低不良事件发生率。
研究设计与样本
- 回顾性、单中心、非随机研究,纳入82眼(82例)原发性黄斑未累及孔源性视网膜脱离伴下方增生性玻璃体视网膜病变,分别使用Oxane HD(45眼)或Densiron 68(37眼)重硅油填充,最终结局基于12个月随访。
主要发现
- Oxane HD组初次手术成功率为66.6%,Densiron 68组为75.6%,差异无统计学意义。
- Oxane HD组最终手术成功率为75.7%,Densiron 68组为81%,差异无统计学意义。
- 最终logMAR增益Oxane HD组为0.36±0.51(中位数0.2),Densiron 68组为0.57±0.58(中位数0.5),P=0.027。
- 两组并发症发生率相似(P>0.05)。
- 两组人口学和临床特征无显著差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the efficacy of heavy silicone oils as endotamponades in the repair of primary complex rhegmatogenous retinal detachment. METHODS: This retrospective, single-centre, nonrandomized study included 82 eyes of 82 patients with primary macular-off rhegmatogenous retinal detachment associated with inferior proliferative vitreoretinopathy. Each eye was treated with one of two heavy silicone oil tamponades: Oxane HD or Densiron 68. Study outcomes were primary and final success rates, final logarithm of the minimum angle of resolution gain, and postoperative complications. The final outcome was based on the 12-month follow-up. RESULTS: Of the 82 eyes, 45 were treated with Oxane HD and 37 with Densiron 68. There were no significant differences in demographic and clinical characteristics between the groups. The primary and final surgical success rates were 66.6% and 75.7% for Oxane HD and 75.6% and 81% for Densiron 68, respectively; these differences were not statistically significant. In addition, the final logarithm of the minimum angle of resolution gain was 0.36 ± 0.51 (median 0.2) in the Oxane HD group and 0.57 ± 0.58 (median 0.5) in the Densiron 68 group ( P = 0.027). Complication rates were similar between groups ( P > 0.05). CONCLUSION: This study suggests that heavy silicone oils may be an effective alternative for suitable patients in primary complex rhegmatogenous retinal detachment cases, demonstrating high anatomical success and a low adverse event profile.
引用
- Ermis S, Ozal E, Karapapak M, et al. ANATOMICAL AND FUNCTIONAL OUTCOMES OF HEAVY SILICONE OIL (OXANE HD AND DENSIRON 68) IN COMPLEX PRIMARY RHEGMATOGENOUS RETINAL DETACHMENT. Retina. 2025. PMID: 39903911. doi:10.1097/IAE.0000000000004419
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。