文献速递青光眼

青光眼视野预测工具验证:一项涉及英国青光眼患者的多中心研究

Validation of a Visual Field Prediction Tool for Glaucoma: A Multicenter Study Involving Patients With Glaucoma in the United Kingdom.
PubMed 文献 · Am J Ophthalmol · 2025-01-13

该回顾性队列研究使用英国多中心真实世界数据(3116例开角型青光眼或可疑患者)验证了先前基于卡尔曼滤波(KF)的视野预测模型PKF,并与两种传统线性回归(LR)模型及新训练的英国KF模型(UK-KF)比较。结果显示,PKF在60个月随访时预测平均偏差(MD)在实测值2.5 dB以内的准确率为75.7%,优于LR模型(P < .01),与UK-KF(75.2%,P = .70)相似;PKF的MD预测落在95%重复性区间内的比例为67.9%,高于LR模型(40.2%、40.9%),与UK-KF(71.4%)相似。结论支持PKF的可推广性,并支持将其纳入临床实践的前瞻性研究。

要点

  • PKF模型在60个月随访时预测MD在实测值2.5 dB以内的准确率为75.7%,优于两种LR模型(P < .01)。
  • PKF的MD预测落在95%重复性区间内的比例为67.9%,高于LR模型(40.2%、40.9%)。
  • PKF与UK-KF的预测准确率(75.7% vs 75.2%,P = .70)和重复性区间比例(67.9% vs 71.4%)相似。

核心结论

  • 本研究在真实世界多中心患者人群中验证了先前开发的KF模型(PKF)的性能。
  • PKF模型显著优于当前临床标准(LR),并对不同青光眼类型和严重程度的患者预测良好。
  • 本研究支持PKF性能的可推广性,并支持将其纳入临床实践的前瞻性研究。

研究设计与样本

  • 回顾性队列研究,使用英国多中心真实世界数据,纳入3116例开角型青光眼或可疑患者,分为训练集(n=1584)和测试集(n=1532)。

主要发现

  • 60个月随访时,PKF预测MD在实测值2.5 dB以内的准确率为75.7%,两种LR模型分别为(P < .01 for both),UK-KF为75.2%(P = .70)。
  • 60个月随访时,PKF的MD预测落在95%重复性区间内的比例为67.9%,两种LR模型分别为40.2%和40.9%,UK-KF为71.4%。

关键数值与推荐

  • PKF预测MD在实测值2.5 dB以内的准确率为75.7%,优于两种LR模型(P < .01 for both),与UK-KF(75.2%,P = .70)相似。
  • PKF的MD预测落在95%重复性区间内的比例为67.9%,高于两种LR模型(40.2%、40.9%),与UK-KF(71.4%)相似。

临床怎么用

  • 本研究支持PKF性能的可推广性,并支持将其纳入临床实践的前瞻性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: A previously developed machine-learning approach with Kalman filtering technology accurately predicted the disease trajectory for patients with various glaucoma types and severities using clinical trial data. This study assesses performance of the KF approach with real-world data. DESIGN: Retrospective cohort study. METHODS: We tested the performance of a previously validated KF model (PKF) initially trained using data from the African Descent and Glaucoma Evaluation Study and the Diagnostic Innovations in Glaucoma Study in patients with different types and severities of glaucoma receiving care in the United Kingdom (UK), comparing the predictive accuracy to 2 conventional linear regression (LR) models and a newly developed KF trained on UK patients (UK-KF). RESULTS: A total of 3116 patients with open-angle glaucoma or suspects were divided into training (n=1584) and testing (n=1532) sets. The predictive accuracy for MD within 2.5 dB of the observed value at 60 months' follow-up for PKF (75.7%) was substantially better than those for the LR models (P < .01 for both) and similar to that for UK-KF (75.2%, P = .70). The proportion of MD predictions in the 95% repeatability intervals at 60 months' follow-up for PKF (67.9%) was higher than those for the LR models (40.2%, 40.9%) and similar to that for UK-KF (71.4%). CONCLUSIONS: This study validates the performance of our previously developed KF model on a real-world, multicenter patient population. Our model substantially outperforms the current clinical standard (LR) and forecasts well for patients with different glaucoma types and severities. This study supports the generalizability of PKF performance and supports prospective study of implementation into clinical practice.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Dean A, Fu DJ, Zhalechian M, et al. Validation of a Visual Field Prediction Tool for Glaucoma: A Multicenter Study Involving Patients With Glaucoma in the United Kingdom. Am J Ophthalmol. 2025. PMID: 39814092. doi:10.1016/j.ajo.2025.01.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。